A comparison of the respiratory signals acquired by different respiratory monitoring systems used in respiratory gated radiotherapy.

PURPOSE Respiratory monitoring systems are used to detect the respiratory phase of patients during the planning and administration of respiratory gated radiotherapy by using four-dimensional computed tomography (4DCT) or 4D positron-emission tomography/CT (4DPET/CT) and the linear accelerator (linac), respectively. Generally, identical respiratory monitoring systems are used for 4DCT, 4DPET/CT, and linac. However, different systems are sometimes used in combination because the accessibility of the respiratory monitoring systems may differ by manufacturer. The combined use of different respiratory monitoring systems in phase-based gating is of concern because the differences in the timing of tags (end-respiration signals algorithmically determined by the respiratory monitoring system), defined by the two systems, may result in phase differences, The purpose of this study is to estimate this difference and evaluate its effect on 4DCT data. METHODS Ten patients (seven men and three women) with a median age of 75 yr (range: 57-84 yr) were treated by gated stereotactic body radiation therapy between April and December 2009. Two types of respiratory monitoring systems--RPM (Varian Medical Systems) and AZ-733V (Anzai MEDICAL)--were placed on the abdominal surface of the patients, and the respiratory signals were acquired by both systems. The relationship between the amplitude peak and the tag obtained by each respiratory system was analyzed for each patient. Further, the 4DCT images were reconstructed by using the signals obtained from both the RPM and the AZ-733V systems, and the tumor volumes and the tumor centroid positions in the craniocaudal plane were analyzed for each patient. RESULTS The correlation factor between the respiratory signals from the RPM system and AZ-733V system was 0.990 (range: 0.940-0.994). The amplitude peak of the RPM system corresponded well with that of the AZ-733V system. The median +/- standard deviation of the phase difference for all the patients ranged from -4.3 +/- 7.1% to 3.5 +/- 2.2%. In the case of some patients, differences were noted between the two systems in the estimation of the tumor centroid position and tumor shape. CONCLUSIONS The estimation of the position of the tumor centroid and tumor shape may vary with the use of different respiratory monitoring systems. This implies that it is preferable to use the same respiratory monitoring system with 4DCT, 4DPET-CT, and linac.

[1]  P. Keall,et al.  A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring. , 2008, Physics in medicine and biology.

[2]  Suresh Senan,et al.  Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[3]  Steve B. Jiang,et al.  Residual motion of lung tumors in end-of-inhale respiratory gated radiotherapy based on external surrogates. , 2006, Medical physics.

[4]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[5]  George Starkschall,et al.  Assessment of lung tumor motion and setup uncertainties using implanted fiducials. , 2007, International journal of radiation oncology, biology, physics.

[6]  Gikas S. Mageras,et al.  Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system , 2001, Journal of applied clinical medical physics.

[7]  George Starkschall,et al.  Displacement-based binning of time-dependent computed tomography image data sets. , 2006, Medical physics.

[8]  Steve B. Jiang,et al.  Internal target volume determined with expansion margins beyond composite gross tumor volume in three-dimensional conformal radiotherapy for lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[9]  R. Mohan,et al.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. , 2003, Medical physics.

[10]  P J Keall,et al.  Accuracy in the localization of thoracic and abdominal tumors using respiratory displacement, velocity, and phase. , 2009, Medical physics.

[11]  Jong Hoon Kim,et al.  Guiding curve based on the normal breathing as monitored by thermocouple for regular breathing. , 2007, Medical physics.

[12]  R Mohan,et al.  Determining parameters for respiration-gated radiotherapy. , 2001, Medical physics.

[13]  Radhe Mohan,et al.  Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[14]  Harry Keller,et al.  Application of the spirometer in respiratory gated radiotherapy. , 2003, Medical physics.

[15]  Steve B. Jiang,et al.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates , 2005, Physics in medicine and biology.

[16]  D. Low,et al.  A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT. , 2006, Medical physics.

[17]  Philippe Lambin,et al.  Effects of radiotherapy planning with a dedicated combined PET-CT-simulator of patients with non-small cell lung cancer on dose limiting normal tissues and radiation dose-escalation: a planning study. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  T. Wiezorek,et al.  Dosimetry of a linear accelerator under respiratory gating. , 2009, Zeitschrift fur medizinische Physik.

[19]  X Allen Li,et al.  Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system. , 2005, Medical physics.

[20]  Suresh Senan,et al.  Literature-based recommendations for treatment planning and execution in high-dose radiotherapy for lung cancer. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  Jean-Philippe Pignol,et al.  Correlation of lung tumor motion with external surrogate indicators of respiration. , 2004, International journal of radiation oncology, biology, physics.

[22]  Gianluca Valentini,et al.  Radiotherapy planning: PET/CT scanner performances in the definition of gross tumour volume and clinical target volume , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[23]  Mitsuhiro Nakamura,et al.  Effect of audio coaching on correlation of abdominal displacement with lung tumor motion. , 2009, International journal of radiation oncology, biology, physics.

[24]  Y. Tsunashima,et al.  Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[25]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[26]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[27]  Wei Lu,et al.  Effect of novel amplitude/phase binning algorithm on commercial four-dimensional computed tomography quality. , 2008, International journal of radiation oncology, biology, physics.

[28]  A. Pevsner,et al.  Quantitation of respiratory motion during 4D-PET/CT acquisition. , 2004, Medical physics.