Noise control for cooling fans on heavy vehicles
暂无分享,去创建一个
In this paper two different objects for fan passive noise control have been examined: heat exchangers and inlet/outlet parallel splitter silencers based on micro-perforated panels. The first object is theoretically and experimentally examined while the second is only examined experimentally. Throughout this paper two measurement methods were used. The ISO 15186-1:2000 to test the acoustic transmission for a diffuse field and plane wave testing in a duct of a sample cut from each heat exchanger type. Based on an anisotropic equivalent fluid model a theoretical model for the heat exchanger acoustic transmission is presented. A new type of splitter silencers based on micro-perforated plates, which can add damping up 10-20 dB in the frequency range of interest (<5 kHz), are also presented.