Foundation heat transfer analysis for buildings with thermal piles

Abstract Thermal piles or thermo-active foundations utilize heat exchangers embedded within foundation footings to heat and/or cool buildings. In this paper, the impact of thermal piles on building foundation heat transfer is investigated. In particular, a simplified analysis method is developed to estimate the annual ground-coupled foundation heat transfer when buildings are equipped with thermal piles. First, a numerical analysis of the thermal performance of thermo-active building foundations is developed and used to assess the interactions between thermal piles and slab-on-grade building foundations. The impact of various design parameters and operating conditions is evaluated including foundation pile depth, building slab width, foundation insulation configuration, and soil thermal properties. Based on the results of a series of parametric analyses, a simplified analysis method is presented to assess the impact of the thermal piles on the annual heat fluxes toward or from the building foundations. A comparative evaluation of the predictions of the simplified analysis method and those obtained from the detailed numerical analysis indicated good agreement with prediction accuracy lower than 5%. Moreover, it is found that thermal piles can affect annual building foundation heat loss/gain by up to 30% depending on foundation size and insulation level.

[1]  Moncef Krarti,et al.  The ITPE technique applied to steady-state ground-coupling problems , 1988 .

[2]  T. Kusuda,et al.  EARTH TEMPERATURE AND THERMAL DIFFUSIVITY AT SELECTED STATIONS IN THE UNITED STATES , 1965 .

[3]  Abdeen Mustafa Omer,et al.  Ground-source heat pumps systems and applications , 2008 .

[4]  Mustafa Inalli,et al.  Temperature distributions in boreholes of a vertical ground-coupled heat pump system , 2009 .

[5]  Per Eskilson Thermal analysis of heat extraction boreholes , 1987 .

[6]  Moncef Krarti,et al.  Analysis of Heat and Moisture Transfer Beneath Freezer Foundations—Part I , 2004 .

[7]  Lyesse Laloui,et al.  Experimental and numerical investigations of the behaviour of a heat exchanger pile , 2006 .

[8]  Simon J. Rees,et al.  A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers , 1999 .

[9]  Marc A. Rosen,et al.  An analytical approach to evaluating the effect of thermal interaction of geothermal heat exchangers on ground heat pump efficiency , 2014 .

[10]  Biagio Morrone,et al.  Energy and economic savings using geothermal heat pumps in different climates , 2014 .

[11]  M. Norusis IBM SPSS Statistics 19 Advanced Statistical Procedures Companion , 2011 .

[12]  H. Brandl Energy foundations and other thermo-active ground structures , 2006 .

[13]  J. McCartney,et al.  Analysis of Thermo-Active Foundations With U-Tube Heat Exchangers , 2012 .

[14]  Moncef Krarti,et al.  Energy Audit of Building Systems : An Engineering Approach , 2000 .

[15]  Moncef Krarti,et al.  Performance of Thermoactive Foundations for Commercial Buildings , 2013 .