Response of Doubly-Fed Induction Generator Wind Energy Conversion System in dynamic situations-wind, grid and converter perturbations

This paper deals with the behavior of the Doubly-Fed Induction Generator Wind Energy Conversion System under forced dynamic circumstances, such as sudden wind speed changes-gusts, harmonically distorted grid voltage and open-circuit fault in power electronic converters. An analysis of these phenomena and fault diagnosis based on Fast Fourier Transformation method has been carried out via simulation using a system of 2 MW.

[1]  Jiabing Hu,et al.  Coordinated Control of DFIG's RSC and GSC Under Generalized Unbalanced and Distorted Grid Voltage Conditions , 2013, IEEE Transactions on Industrial Electronics.

[2]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[3]  Wilfried Hofmann,et al.  A discussion about a start-up procedure of a doubly-fed induction generator system , 2008 .

[4]  A. Petersson Analysis, Modeling and Control of Doubly-Fed Induction Generators for Wind Turbines , 2005 .

[5]  P. Sanchis,et al.  Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips , 2007, IEEE Transactions on Energy Conversion.

[6]  Issarachai Ngamroo,et al.  An Open Circuit Fault Diagnostic Technique in IGBTs for AC to DC Converters Applied in Microgrid Applications , 2011 .

[7]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[8]  Friedrich W. Fuchs,et al.  Power electronic converters in wind energy systems — Considerations of reliability and strategies for increasing availability , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[9]  Shahram Karimi,et al.  FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems , 2008, IEEE Transactions on Industrial Electronics.

[10]  Stavros A. Papathanassiou,et al.  Evaluation of PV Inverter Control Schemes under Distorted and Variable Frequency Grid Conditions , 2013 .

[11]  Jin-Woo Jung,et al.  Improvement of dynamic performance of doubly fed induction generator-based wind turbine power system under an unbalanced grid voltage condition , 2012 .

[12]  E.D. Mitronikas,et al.  Rotor fault detection in inverter drive systems using inverter input current analysis , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.

[13]  Pan Duan,et al.  Open-switch fault diagnosis and system reconfiguration of doubly fed wind power converter used in a microgrid , 2011, IEEE Transactions on Power Electronics.

[14]  S. Nanou,et al.  Full-converter wind generator modelling for transient stability studies , 2011, 2011 IEEE Trondheim PowerTech.

[15]  Dimitrios G. Giaourakis,et al.  Fault Diagnostic Method for Open Circuit of IGBT Converter in Doubly-Fed Induction Generator Wind Energy Conversion System , 2013 .

[16]  E.D. Mitronikas,et al.  Asynchronous Machine Rotor Fault Diagnosis Technique Using Complex Wavelets , 2008, IEEE Transactions on Energy Conversion.

[17]  T.J.E. Miller,et al.  Theory of the doubly-fed induction machine in the steady state , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.

[18]  J. López,et al.  Wind Turbines Based on Doubly Fed Induction Generator Under Asymmetrical Voltage Dips , 2008, IEEE Transactions on Energy Conversion.

[19]  G. D. Marques,et al.  Understanding the Doubly Fed Induction Generator During Voltage Dips , 2012, IEEE Transactions on Energy Conversion.

[20]  M. Liserre,et al.  Power Electronics Converters for Wind Turbine Systems , 2012, IEEE Transactions on Industry Applications.

[21]  Y. Amirat,et al.  DFIG-based wind turbine fault diagnosis using a specific discrete wavelet transform , 2008, 2008 18th International Conference on Electrical Machines.