An automated system for whole microscopic image acquisition and analysis

The field of anatomic pathology has experienced major changes over the last decade. Virtual microscopy (VM) systems have allowed experts in pathology and other biomedical areas to work in a safer and more collaborative way. VMs are automated systems capable of digitizing microscopic samples that were traditionally examined one by one. The possibility of having digital copies reduces the risk of damaging original samples, and also makes it easier to distribute copies among other pathologists. This article describes the development of an automated high‐resolution whole slide imaging (WSI) system tailored to the needs and problems encountered in digital imaging for pathology, from hardware control to the full digitization of samples. The system has been built with an additional digital monochromatic camera together with the color camera by default and LED transmitted illumination (RGB). Monochrome cameras are the preferred method of acquisition for fluorescence microscopy. The system is able to digitize correctly and form large high resolution microscope images for both brightfield and fluorescence. The quality of the digital images has been quantified using three metrics based on sharpness, contrast and focus. It has been proved on 150 tissue samples of brain autopsies, prostate biopsies and lung cytologies, at five magnifications: 2.5×, 10×, 20×, 40×, and 63×. The article is focused on the hardware set‐up and the acquisition software, although results of the implemented image processing techniques included in the software and applied to the different tissue samples are also presented. Microsc. Res. Tech. 77:697–713, 2014. © 2014 Wiley Periodicals, Inc.

[1]  Roger S. Pressman,et al.  Software Engineering: A Practitioner's Approach , 1982 .

[2]  Gregory F Weber,et al.  Color image acquisition using a monochrome camera and standard fluorescence filter cubes. , 2005, BioTechniques.

[3]  I T Young,et al.  A comparison of different focus functions for use in autofocus algorithms. , 1985, Cytometry.

[4]  Dan J. Johnston,et al.  Development and preliminary evaluation of the VPS ReplaySuite: a virtual double-headed microscope for pathology , 2005, BMC Medical Informatics Decis. Mak..

[5]  Shree K. Nayar,et al.  Shape from Focus , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[6]  Joel H. Saltz,et al.  The virtual microscope , 2003, IEEE Transactions on Information Technology in Biomedicine.

[7]  F. Demichelis,et al.  The virtual case: a new method to completely digitize cytological and histological slides , 2002, Virchows Archiv.

[8]  B. Molnár,et al.  Digital slide and virtual microscopy based routine and telepathology evaluation of routine gastrointestinal biopsy specimens , 2003, Journal of clinical pathology.

[9]  Javier Lorenzo-Navarro,et al.  Comparison of focus measures in face detection environments , 2007, ICINCO-RA.

[10]  Kristine A. Erps,et al.  Overview of telepathology, virtual microscopy, and whole slide imaging: prospects for the future. , 2009, Human pathology.

[11]  Oscar Déniz,et al.  Image processing methods and architectures in diagnostic pathology. , 2010, Folia histochemica et cytobiologica.

[12]  Lina J. Karam,et al.  A No-Reference Objective Image Sharpness Metric Based on the Notion of Just Noticeable Blur (JNB) , 2009, IEEE Transactions on Image Processing.

[13]  Sean SP Costello,et al.  Development and Evaluation of the Virtual Pathology Slide: A New Tool in Telepathology , 2003, Journal of medical Internet research.

[14]  Hans Beck,et al.  A European network for virtual microscopy—design, implementation and evaluation of performance , 2009, Virchows Archiv.

[15]  G. Kayser,et al.  Theory and implementation of an electronic, automated measurement system for images obtained from immunohistochemically stained slides. , 2006, Analytical and quantitative cytology and histology.

[16]  R S Weinstein,et al.  Telepathology overview: from concept to implementation. , 2001, Human pathology.

[17]  Christopher Batten Autofocusing and Astigmatism Correction in the Scanning Electron Microscope , 2000 .

[18]  Gloria Bueno García,et al.  Critical Comparison of 31 Commercially Available Digital Slide Systems in Pathology , 2006, International journal of surgical pathology.

[19]  C A Beltrami,et al.  eSlide suite: an open source software system for whole slide imaging , 2009, Journal of Clinical Pathology.

[20]  Levente Ficsor,et al.  Digital Slide and Virtual Microscopy-Based Routine and Telepathology Evaluation of Gastrointestinal Biopsy Specimen , 2009 .

[21]  Lining Sun,et al.  Construction and evaluation of a wavelet‐based focus measure for microscopy imaging , 2007, Microscopy research and technique.

[22]  Christel Daniel-Le Bozec,et al.  Digital Pathology in Europe: Coordinating Patient Care and Research Efforts , 2009, MIE.

[23]  Metin Nafi Gürcan,et al.  Special issue on whole slide microscopic image processing , 2011, Comput. Medical Imaging Graph..

[24]  Andrew Evans,et al.  Digital imaging in pathology: whole-slide imaging and beyond. , 2013, Annual review of pathology.

[25]  R Redondo,et al.  Quality evaluation of microscopy and scanned histological images for diagnostic purposes. , 2012, Micron.

[26]  Gloria Bueno,et al.  Colour model analysis for microscopic image processing , 2008, Diagnostic pathology.

[27]  Vincenzo Della Mea,et al.  A pixel-based autofocusing technique for digital histologic and cytologic slides. , 2005, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[28]  Klaus Kayser,et al.  How to measure image quality in tissue-based diagnosis (diagnostic surgical pathology) , 2008, Diagnostic pathology.

[29]  Oscar Déniz,et al.  13. Microscopic Imaging , 2011 .

[30]  Lina J. Karam,et al.  A No-Reference Image Blur Metric Based on the Cumulative Probability of Blur Detection (CPBD) , 2011, IEEE Transactions on Image Processing.

[31]  Gabriel Cristóbal,et al.  Autofocus evaluation for brightfield microscopy pathology. , 2012, Journal of biomedical optics.

[32]  D. Vollath The influence of the scene parameters and of noise on the behaviour of automatic focusing algorithms , 1988 .

[33]  Oscar Déniz-Suárez,et al.  A parallel solution for high resolution histological image analysis , 2012, Comput. Methods Programs Biomed..

[34]  Ross Cutler,et al.  Practical calibrations for a real-time digital omnidirectional camera , 2001 .

[35]  J. M. Chassery,et al.  Microscopic Imaging , 1991, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991.

[36]  Sim Heng Ong,et al.  Autofocusing for tissue microscopy , 1993, Image Vis. Comput..