A Comprehensive LVRT Control Strategy for DFIG Wind Turbines With Enhanced Reactive Power Support

The paper presents a new control strategy to enhance the ability of reactive power support of a doubly fed induction generator (DFIG) based wind turbine during serious voltage dips. The proposed strategy is an advanced low voltage ride through (LVRT) control scheme, with which a part of the captured wind energy during grid faults is stored temporarily in the rotor's inertia energy and the remaining energy is available to the grid while the DC-link voltage and rotor current are kept below the dangerous levels. After grid fault clearance, the control strategy ensures smooth release of the rotor's excessive inertia energy into the grid. Based on these designs, the DFIG's reactive power capacity on the stator and the grid side converter is handled carefully to satisfy the new grid code requirements strictly. Simulation studies are presented and discussed.

[1]  Hans-Peter Nee,et al.  Model-based current control of AC machines using the internal model control method , 1995 .

[2]  J.V. Milanovic,et al.  Assessing Transient Response of DFIG-Based Wind Plants—The Influence of Model Simplifications and Parameters , 2008, IEEE Transactions on Power Systems.

[3]  Wei Qiao,et al.  Feed-Forward Transient Current Control for Low-Voltage Ride-Through Enhancement of DFIG Wind Turbines , 2010, IEEE Transactions on Energy Conversion.

[4]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[5]  Yong Kang,et al.  An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults , 2011, IEEE Transactions on Power Electronics.

[6]  Jin Yang,et al.  A Series-Dynamic-Resistor-Based Converter Protection Scheme for Doubly-Fed Induction Generator During Various Fault Conditions , 2010, IEEE Transactions on Energy Conversion.

[7]  R. Yokoyama,et al.  Modeling of doubly-fed adjustable-speed machine for analytical studies on long-term dynamics of power system , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[8]  T. Madhavi,et al.  Direct Torque Control for Doubly Fed Induction Machine-Based Wind Turbines under Voltage Dips and Without Crowbar Protection , 2014 .

[9]  Vladislav Akhmatov,et al.  Induction Generators for Wind Power , 2007 .

[10]  Luis Marroyo,et al.  Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[11]  Hui Li,et al.  An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator , 2008, IEEE Transactions on Power Electronics.

[12]  Wu Guo-xiang Low voltage ride-through control of doubly fed induction generator during symmetric voltage sag , 2010 .

[13]  Peter Tavner,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006 .

[14]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[15]  Yongdong Li,et al.  Improved Crowbar Control Strategy of DFIG Based Wind Turbines for Grid Fault Ride-Through , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[16]  Kit Po Wong,et al.  Advanced Control Strategy of DFIG Wind Turbines for Power System Fault Ride Through , 2012, IEEE Transactions on Power Systems.

[17]  M. O'Malley,et al.  The inertial response of induction-machine-based wind turbines , 2005, IEEE Transactions on Power Systems.

[18]  Nicholas Jenkins,et al.  Power system frequency response from fixed speed and doubly fed induction generator-based wind turbines , 2004 .

[19]  Ehab F. El-Saadany,et al.  An improved fault ride-through strategy for doubly fed induction generator-based wind turbines , 2008 .