A MR Compatible Mechatronic System to Facilitate Magic Angle Experiments in Vivo

When imaging tendons and cartilage in a MRI scanner, an increase in signal intensity is observed when they are oriented at 55 degrees with respect to Bo (the "magic angle"). There is a clear clinical importance for considering this effect as part of the diagnosis of orthopaedic and other injury. Experimental studies of this phenomenon have been made harder by practical difficulties of tissue positioning and orientation in the confined environment of cylindrical scanners. An MRI compatible mechatronic system has been developed to position a variety of limbs inside the field of view of the scanner, to be used as a diagnostic and research tool. It is actuated with a novel pneumatic motor comprised of a heavily geared down air turbine, and is controlled in a closed loop using standard optical encoders. MR compatibility is demonstrated as well as the results of preliminary trials used to image the Achilles tendon of human volunteers at different orientations. A 4 to 13 fold increase in signal at the tendon is observed at the magic angle.

[1]  Nobuhiko Hata,et al.  Surgical assist robot for the active navigation in the intraoperative MRI: hardware design issues , 2000, Proceedings. 2000 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2000) (Cat. No.00CH37113).

[2]  Akio Yamamoto,et al.  Actuation Methods for Applications in MR Environments , 2006 .

[3]  D. Larkman,et al.  Contrast-enhanced magic-angle MR imaging of the Achilles tendon. , 2002, AJR. American journal of roentgenology.

[4]  Mark Bydder,et al.  The magic angle effect: A source of artifact, determinant of image contrast, and technique for imaging , 2007, Journal of magnetic resonance imaging : JMRI.

[5]  Essa Yacoub,et al.  Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast. , 2004, Journal of biomechanical engineering.

[6]  J. Hajnal,et al.  Magnetic resonance: magic angle imaging of the Achilles tendon , 2001, The Lancet.

[7]  Nikolaos V Tsekos,et al.  A prototype manipulator for magnetic resonance-guided interventions inside standard cylindrical magnetic resonance imaging scanners. , 2005, Journal of biomechanical engineering.

[8]  Y. Xia,et al.  Magic-Angle Effect in Magnetic Resonance Imaging of Articular Cartilage: A Review , 2000, Investigative radiology.

[9]  S. Erickson,et al.  The "magic angle" effect: background physics and clinical relevance. , 1993, Radiology.

[10]  M. Robson,et al.  Magic angle effects in MR neurography. , 2004, AJNR. American journal of neuroradiology.

[11]  G. Fullerton,et al.  Orientation of tendons in the magnetic field and its effect on T2 relaxation times. , 1985, Radiology.

[12]  M Lampérth,et al.  A Review of Magnetic Resonance Imaging Compatible Manipulators in Surgery , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.