Low-Complexity Motion-Compensated Beamforming Algorithm and Architecture for Synthetic Transmit Aperture in Ultrasound Imaging

Synthetic transmit aperture (STA) has been widely investigated in ultrasound system recently with characteristics of high frame rate and low hardware cost. Since the high-resolution image (HRI) of STA is formed by summation of low-resolution images (LRIs), it is susceptible to inter-firing motions. In this paper, we propose a low-complexity global motion compensation algorithm. We use the common region of interest (ROIcom) between different transmissions of STA imaging to beamform backward and forward beam vectors. Then, the magnitude and direction of motion can be evaluated by cross-correlations between specific beam vectors in STA imaging. Compared with the uncompensated image in two-dimentional (2D) motion environment, the proposed motion compensation algorithm can improve the contrast ratio (CR) and contrast-to-noise ratio (CNR) by 13.73 and 2.04 dB, respectively. Also, the proposed algorithm improves the CR and CNR about 7.84 and 1.36 dB comparing with the reference work, respectively. In the Field II breath model, the proposed method also improves the CR and CNR about 6.65 and 1.04 dB than the reference method, respectively. Moreover, we propose a low-complexity delay generator in the architecture design to further reduce the computational complexity of the whole beamforming system. Finally, we verify the proposed low-complexity motion compensation beamforming engine by using the VLSI implementation with CMOS 90 nm technology. In the post-layout result, the core size is 2.39 mm2 at 125 MHz operating frequency and the frame rate of the beamforming system is 42.23 frames per second.

[1]  An-Yeu Wu,et al.  VLSI implementation of real-time motion compensated beamforming in synthetic transmit aperture imaging , 2013, 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013).

[2]  R. N. Thomson Transverse and longitudinal resolution of the synthetic aperture focusing technique , 1984 .

[3]  Jørgen Arendt Jensen,et al.  Experimental ultrasound system for real-time synthetic imaging , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[4]  G.R. Lockwood,et al.  Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  T. Loupas,et al.  Experimental evaluation of velocity and power estimation for ultrasound blood flow imaging, by means of a two-dimensional autocorrelation approach , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[7]  W. W. Hansen Real-Time Digital Image Reconstruction: A Description of Imaging Hardware and an Analysis of Quantization Errors , 1984 .

[8]  Jørgen Arendt Jensen,et al.  Recursive delay calculation unit for parametric beamformer , 2006, SPIE Medical Imaging.

[9]  An-Yeu Wu,et al.  A unified view for vector rotational CORDIC algorithms and architectures based on angle quantization approach , 2002 .

[10]  J. Arendt Jensen,et al.  Duplex synthetic aperture imaging with tissue motion compensation , 2003 .

[11]  Song B. Park,et al.  An Efficient Real Time Focusing Delay Calculation in Ultrasonic Imaging Systems , 1994 .

[12]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[13]  W.F. Walker,et al.  A spline-based algorithm for continuous time-delay estimation using sampled data , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Jørgen Arendt Jensen,et al.  Delay generation methods with reduced memory requirements , 2003, SPIE Medical Imaging.

[15]  G.E. Trahey,et al.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. I. Basic principles , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Pai-Chi Li,et al.  Strain compounding: a new approach for speckle reduction. , 2002, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[17]  An-Yeu Wu,et al.  Coherent Image Herding of Inhomogeneous Motion Compensation for Synthetic Transmit Aperture in Ultrasound Image , 2012, 2012 IEEE Workshop on Signal Processing Systems.

[18]  Tai-Kyong Song,et al.  Effects and limitations of motion compensation in synthetic aperture techniques , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[19]  K. Thomenius,et al.  Evolution of ultrasound beamformers , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[20]  W. Walker,et al.  A comparison of the performance of time-delay estimators in medical ultrasound , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[23]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE 1985 Ultrasonics Symposium.

[24]  K. Kristoffersen,et al.  Analysis of worst-case phase quantization sidelobes in focused beamforming , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Mohamad Sawan,et al.  Variable delay CMOS implementation for ultrasonic beamforming , 2002, The 14th International Conference on Microelectronics,.

[26]  A. Basarab,et al.  Phase-based block matching applied to motion estimation with unconventional beamforming strategies , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  M. O'Donnell,et al.  Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  An-Yeu Wu,et al.  Mixed-scaling-rotation CORDIC (MSR-CORDIC) algorithm and architecture for high-performance vector rotational DSP applications , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[29]  An-Yeu Wu,et al.  Mixed-scaling-rotation CORDIC (MSR-CORDIC) algorithm and architecture for scaling-free high-performance rotational operations , 2003, 2003 IEEE International Conference on Acoustics, Speech, and Signal Processing, 2003. Proceedings. (ICASSP '03)..

[30]  An-Yeu Wu,et al.  A high-performance/low-latency vector rotational CORDIC architecture based on extended elementary angle set and trellis-based searching schemes , 2003, IEEE Trans. Circuits Syst. II Express Briefs.

[31]  P. Suetens,et al.  Comparison of time-domain displacement estimators for two-dimensional RF tracking. , 2003, Ultrasound in medicine & biology.

[32]  Septimiu E. Salcudean,et al.  Motion Estimation in Ultrasound Images Using Time Domain Cross Correlation With Prior Estimates , 2006, IEEE Transactions on Biomedical Engineering.

[33]  A.C.H. Yu,et al.  A modified synthetic aperture imaging approach with axial motion compensation , 2008, 2008 IEEE Ultrasonics Symposium.

[34]  T. G. Noll,et al.  Low power delay calculation for digital beamforming in handheld ultrasound systems , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[35]  G.R. Lockwood,et al.  Effects of motion on a synthetic aperture beamformer for real-time 3D ultrasound , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[36]  G. Trahey,et al.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[37]  Jørgen Arendt Jensen,et al.  A new architecture for a single-chip multi-channel beamformer based on a standard FPGA , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[38]  Sverre Holm,et al.  Improved framerate with synthetic transmit aperture imaging using prefocused subapertures , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[39]  G.E. Trahey,et al.  Continuous delay estimation with polynomial splines , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[40]  J.A. Jensen,et al.  Fast parametric beamformer for synthetic aperture imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.