Modelling motor cortex stimulation for chronic pain control: Electrical potential field, activating functions and responses of simple nerve fibre models

This computer modelling study on motor cortex stimulation (MCS) introduced a motor cortex model, developed to calculate the imposed electrical potential field characteristics and the initial response of simple fibre models to stimulation of the precentral gyrus by an epidural electrode, as applied in the treatment of chronic, intractable pain. The model consisted of two parts: a three-dimensional volume conductor based on tissue conductivities and human anatomical data, in which the stimulationinnduced potential field was computed, and myelinated nerve fibre models allowing the calculation of their response to this field. A simple afferent fibre branch and three simple efferent fibres leaving the cortex at different positions in the precentral gyrus were implemented. It was shown that the thickness of the cerebrospinal fluid (CSF) layer between the dura mater and the cortex below the stimulating electrode substantially affected the distribution of the electrical potential field in the precentral gyrus and thus the threshold stimulus for motor responses and the therapeutic stimulation amplitude. When the CSF thickness was increased from 0 to 2.5 mm, the load impedance decreased by 28%, and the stimulation amplitude increased by 6.6 V for each millimetre of CSF. Owing to the large anode-cathode distance (10 mm centre-to-centre) in MCS, the cathodal fields in mono- and bipolar stimulation were almost identical. Calculation of activating functions and fibre responses showed that only nerve fibres with a directional component parallel to the electrode surface were excitable by a cathode, whereas fibres perpendicular to the electrode surface were excitable under an anode.

[1]  Jan Voogd,et al.  The human central nervous system : a synopsis and atlas , 1978 .

[2]  G. Shepherd,et al.  Current-density analysis of summed evoked potentials in opossum prepyriform cortex. , 1973, Journal of neurophysiology.

[3]  R. Porter,et al.  Focal stimulation of hypoglossal neurones in the cat , 1963, The Journal of physiology.

[4]  C. G. Phillips,et al.  Unifocal and bifocal stimulation of the motor cortex , 1962, The Journal of physiology.

[5]  R. Davis,et al.  Cortical damage from Zenker's solution applied to the dura mater. , 1981, Neurosurgery.

[6]  J F Stein,et al.  Motor cortex stimulation for neuropathic pain. , 2001, Neurosurgical focus.

[7]  Yong Tang,et al.  A stereological method for estimating the total length and size of myelin fibers in human brain white matter , 1997, Journal of Neuroscience Methods.

[8]  D. Graf von Keyserlingk,et al.  Diameter of axons and thickness of myelin sheaths of the pyramidal tract fibres in the adult human medullary pyramid. , 1984, Anatomischer Anzeiger.

[9]  D F Jiang,et al.  [Study of some morphologic aspects of the human dura mater]. , 1990, Zhonghua wai ke za zhi [Chinese journal of surgery].

[10]  Robert W. Dykes,et al.  Conductivity in the somatosensory cortex of the cat — evidence for cortical anisotropy , 1979, Brain Research.

[11]  J. Holsheimer,et al.  A model of the electrical behaviour of myelinated sensory nerve fibres based on human data , 1999, Medical & Biological Engineering & Computing.

[12]  P Brugières,et al.  Motor cortex stimulation in the treatment of central and neuropathic pain. , 2000, Archives of medical research.

[13]  T Hirayama,et al.  Chronic motor cortex stimulation in patients with thalamic pain. , 1993, Journal of neurosurgery.

[14]  J. Bullier,et al.  Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter I. Evidence from chronaxie measurements , 1998, Experimental Brain Research.

[15]  Thomas A. Zeffiro,et al.  23 – Motor Cortex , 1990 .

[16]  J. Holsheimer,et al.  Recruitment of dorsal column fibers in spinal cord stimulation: influence of collateral branching , 1992, IEEE Transactions on Biomedical Engineering.

[17]  F. Rattay Analysis of Models for External Stimulation of Axons , 1986, IEEE Transactions on Biomedical Engineering.

[18]  C. G. Phillips,et al.  Selective excitation of corticofugal neurones by surface‐anodal stimulation of the baboon's motor cortex , 1962, The Journal of physiology.

[19]  Jiang Df,et al.  Study of some morphologic aspects of the human dura mater , 1990 .

[20]  Philippe Decq,et al.  Chronic motor cortex stimulation in the treatment of central and neuropathic pain. Correlations between clinical, electrophysiological and anatomical data , 1999, PAIN.

[21]  B. Pirotte,et al.  The Zeiss-MKM system for frameless image-guided approach in epidural motor cortex stimulation for central neuropathic pain. , 2001, Neurosurgical focus.

[22]  F. Roux,et al.  Motor cortex stimulation for neuropathic pain. , 2007, Acta neurochirurgica. Supplement.

[23]  Y Shinoda,et al.  Cerebellar input to corticothalamic neurons in layers V and VI in the motor cortex , 1997, Neuroscience Research.

[24]  N. Barbaro,et al.  Motor cortex stimulation for central and neuropathic pain: current status , 2003, Pain.

[25]  D. Mcneal Analysis of a Model for Excitation of Myelinated Nerve , 1976, IEEE Transactions on Biomedical Engineering.

[26]  F. Rattay,et al.  The basic mechanism for the electrical stimulation of the nervous system , 1999, Neuroscience.

[27]  P Mertens,et al.  Electrical stimulation of motor cortex for pain control: a combined PET-scan and electrophysiological study , 1999, PAIN.

[28]  A. Gorman,et al.  Differential patterns of activation of the pyramidal system elicited by surface anodal and cathodal cortical stimulation. , 1966, Journal of neurophysiology.