Functional elbow range of motion for contemporary tasks.

BACKGROUND Elbow range of motion for functional tasks has been previously studied. Motion arcs necessary to complete contemporary tasks such as using a keyboard or cellular telephone have not been studied and could have implications on what is considered to be a functional arc of motion for these tasks. The purpose of this study was to determine elbow range of motion, including flexion-extension, pronation-supination, and varus-valgus angulation, with use of three-dimensional optical tracking technology for several previously described positional and functional tasks along with various contemporary tasks. METHODS Twenty-five patients performed six positional and eleven functional tasks (both historical and contemporary). Elbow flexion-extension, varus-valgus, and forearm rotation (pronation and supination) ranges of motion were measured. RESULTS Positional tasks required a minimum (mean and standard deviation) of 27° ± 7° of flexion and a maximum of 149° ± 5° of flexion. Forearm rotation ranged from 20.0° ± 18° of pronation to 104° ± 10° of supination. Varus and valgus angulations ranged between 2° ± 5° of varus to 9° ± 5° of valgus. For functional tasks, the maximum flexion arc was 130° ± 7°, with a minimum value recorded as 23° ± 6° and a maximum value recorded as 142° ± 3°. All of these were for the cellular telephone task. The maximum pronation-supination arc (103° ± 34°) was found with using a fork. Maximum pronation was found with typing on a keyboard (65° ± 8°). Maximum supination was found with opening a door (77° ± 13°). Maximum varus-valgus arc of motion was 11° ± 4°. Minimum valgus (0° ± 6°) was found with cutting with a knife, while maximum valgus (13° ± 6°) was found with opening a door. CONCLUSIONS Functional elbow range of motion necessary for activities of daily living may be greater than previously reported. Contemporary tasks, such as using a computer mouse and keyboard, appear to require greater pronation than other tasks, and using a cellular telephone usually requires greater flexion than other tasks.

[1]  A. Quanbury,et al.  Normal functional range of motion of upper limb joints during performance of three feeding activities. , 1990, Archives of physical medicine and rehabilitation.

[2]  Wiesław Chwała,et al.  Upper limb joint mobility ranges during activities of daily living determined by three-dimensional motion analysis--preliminary report. , 2007, Ortopedia, traumatologia, rehabilitacja.

[3]  E. Chao,et al.  A biomechanical study of normal functional elbow motion. , 1981, The Journal of bone and joint surgery. American volume.

[4]  Shinji Miyazaki,et al.  Comparison of the performance of 3D camera systems , 1995 .

[5]  B. Morrey,et al.  Arthroscopy of the elbow. Diagnostic and therapeutic benefits and hazards. , 1992, The Journal of bone and joint surgery. American volume.

[6]  Engen Tj,et al.  Method of kinematic study of normal upper extremity movements. , 1968 .

[7]  E. Chao,et al.  Passive motion of the elbow joint. , 1976, The Journal of bone and joint surgery. American volume.

[8]  M. M. Ayoub,et al.  A Stereometric System for Measuring Human Motion , 1970 .

[9]  Shunichi Henmi,et al.  A biomechanical study of activities of daily living using neck and upper limbs with an optical three-dimensional motion analysis system , 2006, Modern rheumatology.

[10]  A functional axis based upper extremity model and associated calibration procedures. , 2010, Gait & posture.

[11]  F C T van der Helm,et al.  Requirements for upper extremity motions during activities of daily living. , 2005, Clinical biomechanics.

[12]  Cynthia E Dunning,et al.  Direct comparison of kinematic data collected using an electromagnetic tracking system versus a digital optical system. , 2007, Journal of biomechanics.

[13]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[14]  S. Azen,et al.  Normal range of motion of joints in male subjects. , 1979, The Journal of bone and joint surgery. American volume.

[15]  Jaap Harlaar,et al.  Complete 3D kinematics of upper extremity functional tasks. , 2008, Gait & posture.

[16]  V. Lees,et al.  THE EFFECT OF ELBOW POSITION ON THE RANGE OF SUPINATION AND PRONATION OF THE FOREARM , 2008, The Journal of hand surgery, European volume.

[17]  P. Raiss,et al.  [Range of motion of shoulder and elbow in activities of daily life in 3D motion analysis]. , 2007, Zeitschrift fur Orthopadie und Unfallchirurgie.

[18]  K. An,et al.  Kinematics of semi-constrained total elbow arthroplasty. , 1992, The Journal of bone and joint surgery. British volume.

[19]  M W Keith,et al.  Functional range of motion of the elbow. , 1995, The Journal of hand surgery.