Efficiently Generating Mixing by Combining Differing Small Amplitude Helical Geometries

Helical geometries have been used in recent years to form cardiovascular prostheses such as stents and shunts. The helical geometry has been found to induce swirling flow, promoting in-plane mixing. This is hypothesised to reduce the formation of thrombosis and neo-intimal hyperplasia, in turn improving device patency and reducing re-implantation rates. In this paper we investigate whether joining together two helical geometries, of differing helical radii, in a repeating sequence, can produce significant gains in mixing effectiveness, by embodying a ‘streamline crossing’ flow environment. Since the computational cost of calculating particle trajectories over extended domains is high, in this work we devised a procedure for efficiently exploring the large parameter space of possible geometry combinations. Velocity fields for the single geometries were first obtained using the spectral/hp element method. These were then discontinuously concatenated, in series, for the particle tracking based mixing analysis of the combined geometry. Full computations of the most promising combined geometries were then performed. Mixing efficiency was evaluated quantitatively using Poincaré sections, particle residence time data, and information entropy. Excellent agreement was found between the idealised (concatenated flow field) and the full simulations of mixing performance, revealing that a strict discontinuity between velocity fields is not required for mixing enhancement, via streamline crossing, to occur. Optimal mixing was found to occur for the combination R = 0.2 D and R = 0.5 D , producing a 70 % increase in mixing, compared with standard single helical designs. The findings of this work point to the benefits of swirl disruption and suggest concatenation as an efficient means to determine optimal configurations of repeating geometries for future designs of vascular prostheses.

[1]  A. Ghatak,et al.  Flow through triple helical microchannel , 2018 .

[2]  C. Caro,et al.  Swirling Flow and Wall Shear: Evaluating the BioMimics 3D Helical Centerline Stent for the Femoropopliteal Segment , 2018, International journal of vascular medicine.

[3]  P. Bártolo,et al.  Optimisation of a Novel Spiral-Inducing Bypass Graft Using Computational Fluid Dynamics , 2017, Scientific Reports.

[4]  H. Leo,et al.  Numerical Assessment of Novel Helical/Spiral Grafts with Improved Hemodynamics for Distal Graft Anastomoses , 2016, PloS one.

[5]  C. Caro,et al.  Helical Centerline Stent Improves Patency: Two-Year Results From the Randomized Mimics Trial , 2016, Circulation. Cardiovascular interventions.

[6]  M. Davies,et al.  Early Results of Using the Spiral Flow AV Graft: Is It a Breakthrough Solution to a Difficult Problem? , 2015 .

[7]  Hojin Ha,et al.  Fluid-Dynamic Optimal Design of Helical Vascular Graft for Stenotic Disturbed Flow , 2014, PloS one.

[8]  R. Krams,et al.  Intimal hyperplasia following implantation of helical-centreline and straight-centreline stents in common carotid arteries in healthy pigs: influence of intraluminal flow† , 2013, Journal of The Royal Society Interface.

[9]  D. Taggart Current status of arterial grafts for coronary artery bypass grafting. , 2013, Annals of cardiothoracic surgery.

[10]  P Segers,et al.  A computational exploration of helical arterio-venous graft designs. , 2013, Journal of biomechanics.

[11]  F. Vermassen,et al.  Spiral laminar flow prosthetic bypass graft: medium-term results from a first-in-man structured registry study. , 2012, Annals of vascular surgery.

[12]  Fergal Boyle,et al.  Reducing In-Stent Restenosis Through Novel Stent Flow Field Augmentation , 2012 .

[13]  Stephen Wiggins,et al.  Eulerian indicators under continuously varying conditions , 2012 .

[14]  Yubo Fan,et al.  ASSESSING HEMODYNAMIC PERFORMANCES OF SMALL DIAMETER HELICAL GRAFTS: TRANSIENT SIMULATION , 2012 .

[15]  Alexander M Seifalian,et al.  Role of prosthetic conduits in coronary artery bypass grafting. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[16]  J. Yoo,et al.  A numerical study on steady flow in helically sinuous vascular prostheses. , 2011, Medical engineering & physics.

[17]  P. Serruys,et al.  Coronary stents: current status. , 2010, Journal of the American College of Cardiology.

[18]  Spencer J. Sherwin,et al.  Using coordinate transformation of Navier-Stokes equations to solve flow in multiple helical geometries , 2010, J. Comput. Appl. Math..

[19]  C. R. Ethier,et al.  Design optimization of a helical endothelial cell culture device , 2010, Biomechanics and modeling in mechanobiology.

[20]  Stephen Wiggins,et al.  Eulerian indicators for predicting and optimizing mixing quality , 2009 .

[21]  J. Akoh,et al.  Prosthetic Arteriovenous Grafts for Hemodialysis , 2009, The journal of vascular access.

[22]  Xiaoyan Deng,et al.  Hemodynamic Performance Study on Small Diameter Helical Grafts , 2009, ASAIO journal.

[23]  P. Boyland Rob Sturman, Julio M. Ottino, and Stephen Wiggins: The mathematical foundations of mixing: the linked twist map as a paradigm in applications, micro to macro, fluids to solids , 2009 .

[24]  D. J. Doorly,et al.  Mixing Through Stirring of Steady Flow in Small Amplitude Helical Tubes , 2009, Annals of Biomedical Engineering.

[25]  G. Coppola,et al.  Arterial geometry, flow pattern, wall shear and mass transport: potential physiological significance , 2009, Journal of The Royal Society Interface.

[26]  N. Cheshire,et al.  Abstract 6059: Novel Helical Stent Design Elicits Swirling Blood Flow Pattern And Inhibits Neointima Formation In Porcine Carotid Arteries , 2008 .

[27]  G Coppola,et al.  Oxygen mass transfer in a model three-dimensional artery , 2008, Journal of The Royal Society Interface.

[28]  Wolfgang Henrik T. Koberg Turbulence control for drag reduction with active wall deformation , 2008 .

[29]  P J Blankestijn,et al.  A helical PTFE arteriovenous access graft to swirl flow across the distal anastomosis: results of a preliminary clinical study. , 2007, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[30]  Sang Joon Kim,et al.  A Mathematical Theory of Communication , 2006 .

[31]  G. Karniadakis,et al.  Spectral/hp Element Methods for Computational Fluid Dynamics , 2005 .

[32]  N. Cheshire,et al.  Preliminary comparative study of small amplitude helical and conventional ePTFE arteriovenous shunts in pigs , 2005, Journal of The Royal Society Interface.

[33]  T. G. Kang,et al.  Colored particle tracking method for mixing analysis of chaotic micromixers , 2004 .

[34]  I. Manas‐Zloczower,et al.  Entropic characterization of distributive mixing in polymer processing equipment , 2003 .

[35]  Patrick Patrick Anderson,et al.  Analysis and Optimization of Kenics Static Mixers , 2003 .

[36]  Shizhi Qian,et al.  A chaotic electroosmotic stirrer. , 2002, Analytical chemistry.

[37]  D. Doorly,et al.  Vortical Flow Structure Identification and Flow Transport in Arteries , 2002, Computer methods in biomechanics and biomedical engineering.

[38]  Spencer J. Sherwin,et al.  Nonlinear particle tracking for high-order elements , 2001 .

[39]  Spencer J. Sherwin,et al.  FLOW PAST A BLUFF BODY WITH A WAVY STAGNATION FACE , 2001 .

[40]  Spencer J. Sherwin,et al.  Flow past a square-section cylinder with a wavy stagnation face , 2001, Journal of Fluid Mechanics.

[41]  S. Sherwin,et al.  The influence of out-of-plane geometry on the flow within a distal end-to-side anastomosis. , 2000, Journal of biomechanical engineering.

[42]  C. R. Ethier,et al.  A numerical study of blood flow patterns in anatomically realistic and simplified end-to-side anastomoses. , 1999, Journal of biomechanical engineering.

[43]  Stephen Wiggins,et al.  Residence-time distributions for chaotic flows in pipes. , 1999, Chaos.

[44]  L. Nielsen,et al.  Transfer of low density lipoprotein into the arterial wall and risk of atherosclerosis. , 1996, Atherosclerosis.

[45]  K. T. Scott,et al.  Non-planar curvature and branching of arteries and non-planar-type flow , 1996, Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[46]  M H Friedman,et al.  Arteriosclerosis research using vascular flow models: from 2-D branches to compliant replicas. , 1993, Journal of biomechanical engineering.

[47]  Hassan Aref,et al.  Chaotic advection by laminar flow in a twisted pipe , 1989, Journal of Fluid Mechanics.

[48]  Julio M. Ottino,et al.  A case study of chaotic mixing in deterministic flows: The partitioned-pipe mixer , 1987 .

[49]  H. Aref Stirring by chaotic advection , 1984, Journal of Fluid Mechanics.

[50]  L Zuckerman,et al.  Shear-induced activation of platelets. , 1979, Journal of biomechanics.

[51]  P. V. Danckwerts The Definition and Measurement of Some Characteristics of Mixtures , 1952 .