Multishot PROPELLER for high‐field preclinical MRI

With the development of numerous mouse models of cancer, there is a tremendous need for an appropriate imaging technique to study the disease evolution. High‐field T2‐weighted imaging using PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction) MRI meets this need. The two‐shot PROPELLER technique presented here provides (a) high spatial resolution, (b) high contrast resolution, and (c) rapid and noninvasive imaging, which enables high‐throughput, longitudinal studies in free‐breathing mice. Unique data collection and reconstruction makes this method robust against motion artifacts. The two‐shot modification introduced here retains more high‐frequency information and provides higher signal‐to‐noise ratio than conventional single‐shot PROPELLER, making this sequence feasible at high fields, where signal loss is rapid. Results are shown in a liver metastases model to demonstrate the utility of this technique in one of the more challenging regions of the mouse, which is the abdomen. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  D G Mitchell,et al.  Hepatic lesions: discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin-echo MR imaging. , 1997, Radiology.

[2]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[3]  G Allan Johnson,et al.  Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents , 2005, Magnetic resonance in medicine.

[4]  S K Holland,et al.  Comparison of SNR and CNR for in vivo mouse brain imaging at 3 and 7 T using well matched scanner configurations. , 2008, Medical physics.

[5]  M. Schnall,et al.  Conventional and fast spin‐echo MR imaging: Minimizing echo time , 1993, Journal of magnetic resonance imaging : JMRI.

[6]  J. Gore,et al.  Relative contributions of chemical exchange and other relaxation mechanisms in protein solutions and tissues , 1989, Magnetic resonance in medicine.

[7]  G Allan Johnson,et al.  Rapid production of specialized animal handling devices using computer‐aided design and solid freeform fabrication , 2009, Journal of magnetic resonance imaging : JMRI.

[8]  R. Henkelman,et al.  Why fat is bright in rare and fast spin‐echo imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[9]  C. Lartizien,et al.  Characterization of neuro-endocrine tumors in an athymic nude mouse model using dedicated synchronization strategies for T2-weigted MR imaging at 7T , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  R R Edelman,et al.  Technologic advances in abdominal MR imaging. , 2001, Radiology.

[11]  L W Hedlund,et al.  MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging. , 2000, Magnetic resonance imaging.

[12]  S. Neubauer,et al.  Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields , 2004, Journal of magnetic resonance imaging : JMRI.

[13]  D. Candinas,et al.  Abdominal magnetic resonance imaging in small rodents using a clinical 1.5 T MR scanner. , 2007, Methods.

[14]  P. Batchelor,et al.  International Society for Magnetic Resonance in Medicine , 1997 .

[15]  E. Purcell,et al.  Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments , 1954 .

[16]  L. Hedlund,et al.  MR microscopy at 7.0 T: Effects of brain iron , 1991, Journal of magnetic resonance imaging : JMRI.

[17]  T K Foo,et al.  Abdominal MR imaging: comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging. , 1993, Radiology.

[18]  Elizabeth A Krupinski,et al.  Radial fast spin‐echo method for T2‐weighted imaging and T2 mapping of the liver , 2002, Journal of magnetic resonance imaging : JMRI.

[19]  A. Sbarbati,et al.  High field MRI in preclinical research. , 2003, European journal of radiology.

[20]  James G Pipe,et al.  Elliptical field‐of‐view PROPELLER imaging , 2009, Magnetic resonance in medicine.

[21]  R. Constable,et al.  Motion artifact in T2‐weighted fast spin‐echo images of the liver: Effect on image contrast and reduction of artifact using respiratory triggering in normal volunteers , 1997, Journal of Magnetic Resonance Imaging.

[22]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[23]  M. Goldberg,et al.  Hepatic hemangiomas and malignant tumors: improved differentiation with heavily T2-weighted conventional spin-echo MR imaging. , 1994, Radiology.

[24]  S. Meiboom,et al.  Modified Spin‐Echo Method for Measuring Nuclear Relaxation Times , 1958 .