Stability and accuracy in a hybrid test example

This paper presents an example of the application of error monitoring techniques to the results of a pseudodynamic test performed at variable testing speeds. For the faster testing speeds, the control errors increased and the test reliability was lost in terms of accuracy and stability, as observed by the evolution of the monitoring parameters. The applied monitoring methods were the spatial model identification of frequency and damping distortions and the error energy, which have been proposed in previous publications. Copyright © 2012 John Wiley & Sons, Ltd.