Applications of ultrasound streaming and radiation force in biosensors.

Direct radiation force (DRF) and acoustic streaming provide the main influences on the behaviour of particles in aqueous suspension in an ultrasound standing wave (USW). The direct radiation force, which drives suspended particles towards and concentrates them in acoustic pressure node planes, has been applied to rapidly transfer cells in small scale analytical separators. The DRF also significantly increased the sensitivity of latex agglutination test (LAT) by concentrating the particles of an analytical sample in the pressure node positions and hence greatly increasing the antibody-antigen encounter rate. Capture of biotinylated particles and spores on a coated acoustic reflector in a quarter wavelength USW resonator was DRF-enhanced by 70- and 100-fold, respectively compared to the situation in the absence of ultrasound. Acoustic streaming has been successfully employed for mixing small analytical samples. Cavitation micro-streaming substantially enhanced, through mixing, DNA hybridization and the capture efficiency of Escherichia coli K12 on the surface of immunomagnetic beads. Acoustic streaming induced in longitudinal standing wave and flexural plate wave immuno-sensors increased the detection of antigens by a factor of five and three times, respectively. Combined DRF and acoustic streaming effects enhanced the rate of the reaction between suspended mixture of cells and retroviruses. The examples of a biochip and an ultrasonic immuno-sensor implementing the DRF and acoustic streaming effects are also described in the review.

[1]  Ihab Abdel-Hamid,et al.  Highly sensitive flow-injection immunoassay system for rapid detection of bacteria , 1999 .

[2]  M A Sobanski,et al.  Ultrasonic enhancement of coated particle agglutination immunoassays: influence of particle density and compressibility. , 1999, Ultrasound in medicine & biology.

[3]  O Doblhoff-Dier,et al.  Selective Retention of Viable Cells in Ultrasonic Resonance Field Devices , 1996, Biotechnology progress.

[4]  J A Rooney,et al.  Hemolysis Near an Ultrasonically Pulsating Gas Bubble , 1970, Science.

[5]  N. J. Harrick,et al.  Internal reflection spectroscopy , 1968 .

[6]  Richard M. White,et al.  A silicon-based ultrasonic immunoassay for detection of breast cancer antigens , 1998 .

[7]  W. Coakley,et al.  Measurement of Serum Antigen Concentration by Ultrasound-Enhanced Immunoassay and Correlation with Clinical Outcome in Meningococcal Disease , 2000, European Journal of Clinical Microbiology and Infectious Diseases.

[8]  M. Zourob,et al.  The development of a metal clad leaky waveguide sensor for the detection of particles , 2003 .

[9]  Jiří Homola,et al.  Comparison of E. coli O157:H7 preparation methods used for detection with surface plasmon resonance sensor , 2005 .

[10]  Dmitri Ivnitski,et al.  Biosensors for detection of pathogenic bacteria , 1999 .

[11]  Bruce D. Bowen,et al.  Measurement of ultrasonic forces for particle–liquid separations , 1997 .

[12]  C. Bondy,et al.  The mechanism of coagulation by ultrasonic waves , 1936 .

[13]  Roger T. Howe,et al.  Microtransport induced by ultrasonic Lamb waves , 1991 .

[14]  Xiao-li Su,et al.  SURFACE PLASMON RESONANCE AND QUARTZ CRYSTAL MICROBALANCE IMMUNOSENSORS FOR DETECTION OF ESCHERICHIA COLI O157:H7 , 2005 .

[15]  W. Coakley,et al.  Increased sensitivity of diagnostic latex agglutination tests in an ultrasonic standing wave field. , 1994, Journal of immunological methods.

[16]  David J. Beebe,et al.  Evaluation of a Three-Dimensional Micromixer in a Surface-Based Biosensor† , 2003 .

[17]  Chris A. Rowe-Taitt,et al.  Simultaneous detection of six biohazardous agents using a planar waveguide array biosensor. , 2000, Biosensors & bioelectronics.

[18]  J. Ho,et al.  Liposome-based microcapillary immunosensor for detection of Escherichia coli O157:H7. , 2004, Analytical biochemistry.

[19]  Spengler,et al.  Ultrasound conditioning of suspensions--studies of streaming influence on particle aggregation on a lab- and pilot-plant scale , 2000, Ultrasonics.

[20]  C. Peng,et al.  Retroviral Transduction of Adherent Cells in Resonant Acoustic Fields , 2008, Biotechnology progress.

[21]  Robin H. Liu,et al.  Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. , 2004, Analytical chemistry.

[22]  Raj Mutharasan,et al.  Detection of pathogen Escherichia coli O157:H7 AT 70 cells/mL using antibody-immobilized biconical tapered fiber sensors. , 2005, Biosensors & bioelectronics.

[23]  D. Miller,et al.  A review of the ultrasonic bioeffects of microsonation, gas-body activation, and related cavitation-like phenomena. , 1987, Ultrasound in medicine & biology.

[24]  Jeremy J Hawkes,et al.  Ultrasonic deposition of cells on a surface. , 2004, Biosensors & bioelectronics.

[25]  Martyn Hill,et al.  Modelling of layered resonators for ultrasonic separation. , 2002, Ultrasonics.

[26]  Pekka Hänninen,et al.  Ultrasonic enrichment of microspheres for ultrasensitive biomedical analysis in confocal laser-scanning fluorescence detection , 2004 .

[27]  Yoshizo Matsuno,et al.  Migration of suspended particles in plane stationary ultrasonic field , 1981 .

[28]  Thomas Laurell,et al.  Carrier medium exchange through ultrasonic particle switching in microfluidic channels. , 2005, Analytical chemistry.

[29]  W Terence Coakley,et al.  Sub-micron particle behaviour and capture at an immuno-sensor surface in an ultrasonic standing wave. , 2005, Biosensors & bioelectronics.

[30]  M D Luque de Castro,et al.  Ultrasound-assisted Soxhlet extraction: an expeditive approach for solid sample treatment. Application to the extraction of total fat from oleaginous seeds. , 2004, Journal of chromatography. A.

[31]  P. K. Sinha,et al.  Ultrasonic treatment of liquid waste containing EDTA , 2004 .

[32]  C. Peng,et al.  Enhanced retroviral gene delivery in ultrasonic standing wave fields , 2005, Gene Therapy.

[33]  S. Yao,et al.  Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance. , 2002, Biosensors & bioelectronics.

[34]  M. Zourob,et al.  Optical leaky waveguide sensor for detection of bacteria with ultrasound attractor force. , 2005, Analytical chemistry.

[35]  F Ying-Sing,et al.  Piezoelectric crystal for sensing bacteria by immobilizing antibodies on divinylsulphone activated poly-m-aminophenol film. , 2000, Talanta.

[36]  R W Ellis,et al.  Diagnostic particle agglutination using ultrasound: a new technology to rejuvenate old microbiological methods. , 2000, Journal of medical microbiology.

[37]  W. Coakley,et al.  Ultrasonic Trap To Monitor Morphology and Stability of Developing Microparticle Aggregates , 2003 .

[38]  E. Perkins,et al.  Development of instrumentation to allow the detection of microorganisms using light scattering in combination with surface plasmon resonance. , 2000, Biosensors & bioelectronics.

[39]  Jing Li,et al.  Monitoring of integrin-mediated adhesion of human ovarian cancer cells to model protein surfaces by quartz crystal resonators: evaluation in the impedance analysis mode. , 2005, Biosensors & bioelectronics.

[40]  C. Malins,et al.  Imaging of unlabelled bacteria at a sensor surface using aluminium-clad integrated waveguide chips , 2004 .

[41]  Robin H. Liu,et al.  Hybridization enhancement using cavitation microstreaming. , 2003, Analytical chemistry.

[42]  Frederick R Haselton,et al.  Chaotic mixer improves microarray hybridization. , 2004, Analytical biochemistry.

[43]  Guimarães EUROSENSORS XVII : book of abstracts , 2003 .

[44]  Kenneth D. Frampton,et al.  The scaling of acoustic streaming for application in micro-fluidic devices , 2003 .

[45]  C. Steinem,et al.  Piezoelectric Mass-Sensing Devices as Biosensors-An Alternative to Optical Biosensors? , 2000, Angewandte Chemie.

[46]  L. Rayleigh,et al.  The theory of sound , 1894 .

[47]  W. Coakley,et al.  Detection of meningitis antigens in buffer and body fluids by ultrasound-enhanced particle agglutination. , 1997, Journal of immunological methods.

[48]  Malcolm Guiver,et al.  Ultrasound-Enhanced Latex Immunoagglutination and PCR as Complementary Methods for Non-Culture-Based Confirmation of Meningococcal Disease , 1999, Journal of Clinical Microbiology.

[49]  G L Hayward,et al.  Acoustic waves and the study of biochemical macromolecules and cells at the sensor-liquid interface. , 1999, The Analyst.

[50]  Jeremy J. Hawkes,et al.  Ultrasonic manipulation of particles in microgravity , 1998 .

[51]  L. D. Rozenberg,et al.  High‐Intensity Ultrasonic Fields , 1971 .

[52]  E J Jarvi,et al.  Piezoelectric quartz crystal biosensors. , 1998, Talanta.

[53]  W. T. Coakley,et al.  Particle column formation in a stationary ultrasonic field , 1992 .

[54]  Kenji Yasuda Non-destructive, non-contact handling method for biomaterials in micro-chamber by ultrasound , 2000 .

[55]  Larisa A. Kuznetsova,et al.  Microparticle concentration in short path length ultrasonic resonators: Roles of radiation pressure and acoustic streaming , 2004 .

[56]  W. Coakley,et al.  Ultrasound enhanced detection of individual meningococcal serogroups by latex immunoassay. , 2002, Journal of clinical pathology.

[57]  Martyn Hill,et al.  Spore and micro-particle capture on an immunosensor surface in an ultrasound standing wave system. , 2005, Biosensors & bioelectronics.

[58]  Kenneth T. Christensen,et al.  Microstreaming Effects on Particle Concentration in an Ultrasonic Standing Wave , 2003 .

[59]  R. Munro,et al.  Ultrasound‐enhanced latex immunoagglutination test (USELAT) for detection of capsular polysaccharide antigen of Neisseria meningitidis from CSF and plasma , 2003, Pathology.

[60]  Nam-Trung Nguyen,et al.  Acoustic streaming in micromachined flexural plate wave devices: numerical simulation and experimental verification , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[61]  W. Coakley,et al.  Ultrasonic separations in analytical biotechnology. , 1997, Trends in biotechnology.

[62]  N. E. Thomas,et al.  Measurement of antigen concentration by an ultrasound-enhanced latex immunoagglutination assay. , 1996, Ultrasound in medicine & biology.

[63]  P. Upadhyay,et al.  A novel ultrasound-enhanced latex agglutination test for the detection of antibodies against Mycobacterium tuberculosis in serum. , 2002, Journal of immunological methods.