Drug impurity profiling by capillary electrophoresis/mass spectrometry using various ionization techniques.

Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even- and odd-electron ions, whereas the other ionization techniques produced even-electron ions only. In-source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full-scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6-dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol.

[1]  D. Barrett,et al.  A generic approach to the impurity profiling of drugs using standardised and independent capillary zone electrophoresis methods coupled to electrospray ionisation mass spectrometry , 2005, Electrophoresis.

[2]  G. D. de Jong,et al.  Capillary electrophoresis-mass spectrometry for impurity profiling of basic pharmaceuticals using non-volatile background electrolytes. , 2007, Journal of chromatography. A.

[3]  Phosphate buffers in capillary electrophoresis/mass spectrometry using atmospheric pressure photoionization and electrospray ionization. , 2003, Rapid communications in mass spectrometry : RCM.

[4]  M. Blades,et al.  State-of-the-art in atmospheric pressure photoionization for LC/MS. , 2008, Analytica chimica acta.

[5]  Pietro Traldi,et al.  Rapid Commun. Mass Spectrom.10. 1629-1637 (1996) Matrix-assisted Laser Desorption/Ionisation Mass Spectrometry in Milk Science , 1997 .

[6]  C. Enke,et al.  Practical implications of some recent studies in electrospray ionization fundamentals. , 2001, Mass spectrometry reviews.

[7]  Serge Rudaz,et al.  Coupling CE with atmospheric pressure photoionization MS for pharmaceutical basic compounds: Optimization of operating parameters , 2007, Electrophoresis.

[8]  Amjad Khan,et al.  Comparison of atmospheric pressure photoionization and ESI for CZE‐MS of drugs , 2007, Electrophoresis.

[9]  R. N. Rao,et al.  Development and validation of a robust capillary electrophoresis method for impurity profiling of etomidate including the determination of chiral purity using a dual cyclodextrin system , 2006, Electrophoresis.

[10]  G. J. Jong,et al.  Capillary electrophoresis-atmospheric pressure chemical ionization-mass spectrometry using an orthogonal interface: Set-up and system parameters , 2009, Journal of the American Society for Mass Spectrometry.

[11]  A. Bruins Mass spectrometry with ion sources operating at atmospheric pressure , 1991 .

[12]  K. Otsuka,et al.  Evaluation of an atmospheric pressure chemical ionization interface for capillary electrophoresis-mass spectrometry. , 2003, Journal of pharmaceutical and biomedical analysis.

[13]  G. D. de Jong,et al.  On‐line capillary electrophoresis‐mass spectrometry using dopant‐assisted atmospheric pressure photoionization: Setup and system performance , 2005, Electrophoresis.

[14]  Christopher Herbert,et al.  Liquid Chromatography/Mass Spectrometry (LC/MS) , 2002 .

[15]  Tony W. T. Bristow,et al.  Photon-independent gas-phase-ion formation in capillary electrophoresis-mass spectrometry using atmospheric pressure photoionization. , 2007, Analytical chemistry.

[16]  S. Görög New safe medicines faster: the role of analytical chemistry , 2003 .

[17]  Amjad Khan,et al.  Comparison of electrospray ionization and atmospheric pressure photoionization for coupling of micellar electrokinetic chromatography with ion trap mass spectrometry. , 2008, Journal of chromatography. A.

[18]  Dora Visky,et al.  Capillary electrophoresis‐mass spectrometry in impurity profiling of pharmaceutical products , 2005, Electrophoresis.

[19]  Ulrike Holzgrabe,et al.  Why not using capillary electrophoresis in drug analysis? , 2006, Electrophoresis.

[20]  M. A. Kelly,et al.  Optimisation, validation and application of a capillary electrophoresis method for the determination of ranitidine hydrochloride and related substances. , 1998, Journal of chromatography. A.

[21]  W. Niessen Liquid Chromatography-Mass Spectrometry, Third Edition , 2006 .

[22]  K. Altria Determination of salbutamol-related impurities by capillary electrophoresis , 1993 .

[23]  S. Gorog Drug safety, drug quality, drug analysis , 2008 .