A stabler non contact atomic force microscopy imaging using a tuning fork for air and liquid environments: The zero phase mode atomic force microscopy

We describe a method to perform noncontact atomic force microscopy (NC-AFM) in liquid and in air using a quartz crystal tuning fork. The latter, thanks to its increased stability originating from its higher stiffness, compared to cantilevers, enables very low oscillation amplitudes and thus, should yield a very high sensitivity to the force interactions. However, applying conventional NC-AFM technique fails, due to the phase lock loop demodulator becoming unstable as the input signal to noise ratio decreases when lowering the oscillation amplitude. Therefore we have developed so-called zero phase mode atomic force microscopy based on phase modulation. Comparisons with conventional frequency modulation mode using the same mechanical setup demonstrate gains in sensitivity and in scanning rates. High resolution topographic images, as well as simultaneous dissipation images can be recorded using this very convenient and effective technique.

[1]  Hendrik Hölscher,et al.  Theory of phase-modulation atomic force microscopy with constant-oscillation amplitude , 2008 .

[2]  Takeshi Fukuma,et al.  Phase modulation atomic force microscope with true atomic resolution , 2006 .

[3]  A. Shluger,et al.  A comparison of dynamic atomic force microscope set-ups for performing atomic scale manipulation experiments , 2007 .

[4]  D. Fotiadis,et al.  Quantitative dynamic-mode scanning force microscopy in liquid, , 2006 .

[5]  Hemantha K. Wickramasinghe,et al.  Atomic force microscope–force mapping and profiling on a sub 100‐Å scale , 1987 .

[6]  John E. Sader,et al.  Coupling of conservative and dissipative forces in frequency-modulation atomic force microscopy , 2006 .

[7]  Hendrik Hölscher,et al.  Quantitative measurement of tip-sample interactions in amplitude modulation atomic force microscopy , 2006 .

[8]  Bielefeldt,et al.  Subatomic Features on the Silicon (111)-(7x7) Surface Observed by Atomic Force Microscopy. , 2000, Science.

[9]  K. Karrai,et al.  Piezoelectric tip‐sample distance control for near field optical microscopes , 1995 .

[10]  E. Meyer,et al.  Fast digital electronics for application in dynamic force microscopy using high-Q cantilevers , 1998 .

[11]  J. Mannhart,et al.  Evaluation of a force sensor based on a quartz tuning fork for operation at low temperatures and ultrahigh vacuum , 2002 .

[12]  D. Rugar,et al.  Frequency modulation detection using high‐Q cantilevers for enhanced force microscope sensitivity , 1991 .

[13]  Takeshi Fukuma,et al.  Development of liquid-environment frequency modulation atomic force microscope with low noise deflection sensor for cantilevers of various dimensions , 2006 .

[14]  H. Freund,et al.  Double quartz tuning fork sensor for low temperature atomic force and scanning tunneling microscopy , 2004 .

[15]  Venceslav F. Kroupa,et al.  Phase Lock Loops and Frequency Synthesis , 2003 .

[16]  Věnceslav F. Kroupa,et al.  Phase Lock Loops and Frequency Synthesis: Kroupa/Phase Lock Loops , 2005 .

[17]  Franz J. Giessibl,et al.  Advances in atomic force microscopy , 2003, cond-mat/0305119.

[18]  M. Stark,et al.  Fast low-cost phase detection setup for tapping-mode atomic force microscopy , 1999 .

[19]  T. Zambelli,et al.  An experimental investigation of resonance curves on metallic surfaces in dynamic force microscopy: the influence of frozen versus mobile charges , 2004 .

[20]  Y. Sugawara,et al.  Phase modulation atomic force microscopy in constant excitation mode capable of simultaneous imaging of topography and energy dissipation , 2008 .

[21]  J. Mannhart,et al.  Calculation of the optimal imaging parameters for frequency modulation atomic force microscopy , 1999 .

[22]  Yan Jun Li,et al.  Elimination of instabilities in phase shift curves in phase-modulation atomic force microscopy in constant-amplitude mode , 2007 .