Dual-Modality Imaging: Combining Anatomy and Function*

The extensive development of image fusion techniques over the past 20 y has shown that the fusion of images from complementary modalities offers a more complete and accurate assessment of disease than do images from a single modality. Although software techniques have been successful in fusing images of the brain from different modalities, they have achieved rather limited success for other parts of the body. The recent introduction of technology that can acquire both anatomic and functional images in a single scan has addressed many of the limitations of software fusion. The combination of CT and PET was introduced commercially in 2001, followed by CT and SPECT in 2004. Clinical adoption of PET/CT has been surprisingly rapid, and despite continuing debate, the new technology has advanced the use of clinical molecular imaging, particularly for oncology.

[1]  R. Wahl,et al.  "Anatometabolic" tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  B. Rutt,et al.  A prototype high-purity germanium detector system with fast photon-counting circuitry for medical imaging. , 1991, Medical physics.

[3]  Soo Chin Liew,et al.  Object-specific attenuation correction of SPECT with correlated dual-energy X-ray CT , 1993, IEEE Transactions on Nuclear Science.

[4]  S. Cherry,et al.  Physics in Nuclear Medicine , 2004 .

[5]  Soo Chin Liew,et al.  Description of a prototype emission-transmission computed tomography imaging system. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Thomas Beyer,et al.  PET/CT scanners: a hardware approach to image fusion. , 2003, Seminars in nuclear medicine.

[7]  W. Kalender,et al.  Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. , 2001, Medical physics.

[8]  D. Townsend,et al.  Physical Performance and Clinical Workflow of a new LSO HI-REZ PET/CT Scanner , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[9]  James A. Scott,et al.  Positron Emission Tomography: Basic Science and Clinical Practice , 2004 .

[10]  Thomas Beyer,et al.  Radiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Wolfgang A Weber,et al.  Use of PET for monitoring cancer therapy and for predicting outcome. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  D. Townsend,et al.  Performance and clinical workflow of a new combined PET/CT scanner , 2007 .

[13]  W. Oyen,et al.  Impact of Ge-68/Ga-68-based versus CT-based attenuation correction on PET. , 2007, Medical physics.

[14]  Holger Greess,et al.  Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers , 1999, European Radiology.

[15]  O. Schober,et al.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes. , 2007, Medical physics.

[16]  Yuji Nakamoto,et al.  Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[17]  Xuan Liu,et al.  Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET , 2001, IEEE Transactions on Medical Imaging.

[18]  Thomas Beyer,et al.  Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[19]  Vladimir Y. Panin,et al.  Fully 3-D PET reconstruction with system matrix derived from point source measurements , 2006, IEEE Transactions on Medical Imaging.

[20]  Thomas Beyer,et al.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. , 2003, Seminars in nuclear medicine.

[21]  Clinical PET/CT imaging: promises and misconceptions. , 2005, Nuklearmedizin. Nuclear medicine.

[22]  T. Budinger Time-of-flight positron emission tomography: status relative to conventional PET. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[23]  Robert M. Lewitt,et al.  Application of the row action maximum likelihood algorithm with spherical basis functions to clinical PET imaging , 2001 .

[24]  Thomas Beyer,et al.  CT-based attenuation correction for PET/CT scanners in the presence of contrast agent , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[25]  Damini Dey,et al.  Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  Y. Erdi,et al.  Respiratory artefact causing malpositioning of liver dome lesion in right lower lung. , 2003, Clinical nuclear medicine.

[27]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[28]  Heinrich R Schelbert,et al.  Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[29]  Paul Kinahan,et al.  Cine CT for Attenuation Correction in Cardiac PET/CT , 2007, Journal of Nuclear Medicine.

[30]  Sui Shen,et al.  MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan , 2009, Journal of Nuclear Medicine.

[31]  V. Treyer,et al.  Objective and subjective comparison of standard 2-D and fully 3-D reconstructed data on a PET/CT system , 2007, Nuclear medicine communications.

[32]  Tinsu Pan,et al.  Frequent Diagnostic Errors in Cardiac PET/CT Due to Misregistration of CT Attenuation and Emission PET Images: A Definitive Analysis of Causes, Consequences, and Corrections , 2007, Journal of Nuclear Medicine.

[33]  Bernd J. Pichler,et al.  Simultaneous MR/PET for brain imaging: First patient scans , 2007 .

[34]  S. Holm,et al.  PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[35]  Cyrill Burger,et al.  Artifacts at PET and PET/CT caused by metallic hip prosthetic material. , 2003, Radiology.

[36]  Roberto A. Isoardi,et al.  Volume Imaging Tomographs , 1998 .

[37]  S. Matej,et al.  Iterative image reconstruction using geometrically ordered subsets with list-mode data , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[38]  Charles C. Watson,et al.  ECAT ART — a continuously rotating PET camera: Performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department , 2005, European Journal of Nuclear Medicine.

[39]  Masatoshi Itoh,et al.  Estimation of absorbed dose for 2-[F-18]fluoro-2-deoxy-d- glucose using whole-body positron emission tomography and magnetic resonance imaging , 1998, European Journal of Nuclear Medicine.

[40]  J. Karp,et al.  Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[41]  Yuji Nakamoto,et al.  PET/CT: artifacts caused by bowel motion , 2004, Nuclear medicine communications.

[42]  K. Takagi,et al.  Cerium‐activated Gd2SiO5 single crystal scintillator , 1983 .

[43]  M. Lodge,et al.  Comparison of 2-dimensional and 3-dimensional acquisition for 18F-FDG PET oncology studies performed on an LSO-based scanner. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[44]  Thomas Beyer,et al.  Positron emission tomography/computed tomography--imaging protocols, artifacts, and pitfalls. , 2004, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[45]  G. Schulthess Molecular anatomic imaging : PET-CT and SPECT-CT integrated modality imaging , 2007 .

[46]  Ora Israel,et al.  Early detection of cancer recurrence: 18F-FDG PET/CT can make a difference in diagnosis and patient care. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[47]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[48]  M. Braun,et al.  Software for image registration: algorithms, accuracy, efficacy. , 2003, Seminars in nuclear medicine.

[49]  Gerald Antoch,et al.  Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[50]  Roberta Matheoud,et al.  Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[51]  C. Comtat,et al.  Fast reconstruction of 3-D PET data with accurate statistical modeling , 1997 .

[52]  Nassir Navab,et al.  Dual cardiac–respiratory gated PET: implementation and results from a feasibility study , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[53]  Piotr J Slomka,et al.  Software Approach to Merging Molecular with Anatomic Information , 2004 .

[54]  David J. Hawkes,et al.  Coregistration of Structural and Functional Images , 2005 .

[55]  R. Raupach,et al.  Combined 18F-FDG-PET/CT imaging of the head and neck , 2006, Nuklearmedizin.

[56]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[57]  Paul Kinahan,et al.  Attenuation correction for a combined 3D PET/CT scanner. , 1998, Medical physics.

[58]  H Zaidi The quest for the ideal anato-molecular imaging fusion tool , 2006, Biomedical imaging and intervention journal.

[59]  David W. Townsend,et al.  Positon emission tomography: basic science and clinical practice , 2008 .

[60]  Yuji Nakamoto,et al.  Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[61]  Soo Chin Liew,et al.  Description of a simultaneous emission-transmission CT system , 1990, Medical Imaging.

[62]  C. Melcher,et al.  Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[63]  Stephen R Thomas,et al.  MIRD dose estimate report no. 19: radiation absorbed dose estimates from (18)F-FDG. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[64]  Tinsu Pan,et al.  Quantifying the effect of IV contrast media on integrated PET/CT: clinical evaluation. , 2006, AJR. American journal of roentgenology.

[65]  M P Sandler,et al.  Image fusion using an integrated, dual-head coincidence camera with X-ray tube-based attenuation maps. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[66]  Osman Ratib,et al.  Comparison between 18F-FDG PET, in-line PET/CT, and software fusion for restaging of recurrent colorectal cancer. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[67]  Thomas Beyer,et al.  Optimized contrast-enhanced CT protocols for diagnostic whole-body 18F-FDG PET/CT: technical aspects of single-phase versus multiphase CT imaging. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[68]  D W. Townsend,et al.  Combined PET/CT Imaging in Oncology. Impact on Patient Management. , 2000, Clinical positron imaging : official journal of the Institute for Clinical P.E.T.

[69]  C B Caldwell,et al.  Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT: the impact of 18FDG-hybrid PET fusion. , 2001, International journal of radiation oncology, biology, physics.

[70]  C A Pelizzari,et al.  Using vascular structure for CT-SPECT registration in the pelvis. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[71]  Habib Zaidi,et al.  Is radionuclide transmission scanning obsolete for dual-modality PET/CT systems? , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[72]  R. Wahl,et al.  Initial experience with oral contrast in PET/CT: phantom and clinical studies. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[73]  Michael Wilk,et al.  Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images , 2000, European Journal of Nuclear Medicine.

[74]  Richard L Wahl,et al.  Applications of positron emission tomography/computed tomography image fusion in clinical positron emission tomography-clinical use, interpretation methods, diagnostic improvements. , 2003, Seminars in nuclear medicine.

[75]  S. Bacharach PET/CT Attenuation Correction: Breathing Lessons , 2007, Journal of Nuclear Medicine.

[76]  Single-detector helical CT in PET-CT: assessment of image quality. , 2004, AJR. American journal of roentgenology.

[77]  R. Castillo,et al.  Attenuation correction of PET images with respiration-averaged CT images in PET/CT. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[78]  T. Beyer,et al.  Putting ‘clear’ into nuclear medicine: a decade of PET/CT development , 2006, European Journal of Nuclear Medicine and Molecular Imaging.

[79]  B. H. Hasegawa,et al.  Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment , 1995 .

[80]  G Bosmans,et al.  Phased attenuation correction in respiration correlated computed tomography/positron emitted tomography. , 2006, Medical physics.

[81]  Gerald Q. Maguire,et al.  Comparison and evaluation of retrospective intermodality brain image registration techniques. , 1997, Journal of computer assisted tomography.

[82]  G Brix,et al.  PET/CT , 2005, Nuklearmedizin.

[83]  Thomas Beyer,et al.  Respiration artifacts in whole-body 18F-FDG PET/CT studies with combined PET/CT tomographs employing spiral CT technology with 1 to 16 detector rows , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[84]  W. Kalender,et al.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. , 1990, Radiology.

[85]  Heiko Schöder,et al.  Deep-Inspiration Breath-Hold PET/CT: Clinical Findings with a New Technique for Detection and Characterization of Thoracic Lesions , 2007, Journal of Nuclear Medicine.

[86]  C. Comtat,et al.  OSEM-3D reconstruction strategies for the ECAT HRRT , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[87]  Gustav K. von Schulthess,et al.  Clinical evaluation of a breathing protocol for PET/CT , 2004, European Radiology.

[88]  Jack Valentin,et al.  Managing patient dose in computed tomography , 2000 .

[89]  Thomas Beyer,et al.  To enhance or not to enhance? 18F-FDG and CT contrast agents in dual-modality 18F-FDG PET/CT. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[90]  Paul Kinahan,et al.  Analytic 3D image reconstruction using all detected events , 1989 .

[91]  R. Wahl,et al.  PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[92]  Heiko Schöder,et al.  Deep-inspiration breath-hold PET/CT of the thorax. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[93]  Charles C. Watson,et al.  CHAPTER 11 – PET/CT Systems , 2004 .

[94]  Paul Kinahan,et al.  A combined PET/CT scanner for clinical oncology. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[95]  J. Mazziotta,et al.  MRI‐PET Registration with Automated Algorithm , 1993, Journal of computer assisted tomography.

[96]  Stefan Eberl,et al.  Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[97]  Peter Knoll,et al.  Use of segmented CT transmission map to avoid metal artifacts in PET images by a PET-CT device , 2005, BMC nuclear medicine.

[98]  Cyrill Burger,et al.  Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner , 2003, European Radiology.

[99]  D. Faul,et al.  A method for calibrating the CT-based attenuation correction of PET in human tissue , 2004, IEEE Transactions on Nuclear Science.

[100]  Jean-Claude Liehn,et al.  Respiratory motion artefact in the liver dome on FDG PET/CT: comparison of attenuation correction with CT and a caesium external source , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[101]  David G. Vass,et al.  Proceedings of the Society of Photo-optical Instrumentation Engineers (SPIE) , 1997 .

[102]  J. Nuyts,et al.  Suppression of metal streak artifacts in CT using a MAP reconstruction procedure , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[103]  R. Coleman,et al.  Concurrent PET/CT with an integrated imaging system: intersociety dialogue from the joint working group of the American College of Radiology, the Society of Nuclear Medicine, and the Society of Computed Body Tomography and Magnetic Resonance. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[104]  Johannes Czernin,et al.  Standard PET/CT of the chest during shallow breathing is inadequate for comprehensive staging of lung cancer. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[105]  Val J Lowe,et al.  NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[106]  D. Townsend,et al.  Method for transforming CT images for attenuation correction in PET/CT imaging. , 2006, Medical physics.

[107]  J. Valentin,et al.  Radiation dose to patients from radiopharmaceuticals: (Addendum 2 to ICRP Publication 53) ICRP Publication 80 Approved by the Commission in September 1997 , 1998, Annals of the ICRP.

[108]  A. Buck,et al.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[109]  D. Townsend,et al.  The Theory and Practice of 3D PET , 1998, Developments in Nuclear Medicine.

[110]  Tinsu Pan,et al.  Design of respiration averaged CT for attenuation correction of the PET data from PET/CT. , 2007, Medical physics.

[111]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.