Application of STATCOM to improve the LVRT of DFIG during RSC fire-through fault

The use of doubly fed induction generators (DFIGs) in large wind energy conversion systems (WECS) has significantly increased during the last few years. The DFIG is interfaced to the AC network through a grid side voltage source converter (GSC) and a rotor side voltage source converter (RSC) to enable the variable speed operation of the wind turbine. Moreover, it provides reactive power support to the AC grid during disturbances. The sensitivity of DFIGs to external faults has motivated researchers to investigate the impact of various grid disturbances, such as voltage sag and short circuit faults, on the low voltage ride through (LVRT) capability of DFIGs. However, no attempts have been made to investigate the impact of converter internal faults on the LVRT of the DFIG-based WECS. In this paper, the impact of a fire-through fault when it occurs in the RSC on the DC-capacitor voltage, rotor current, and the LVRT capability of the DFIG is investigated. A STATCOM controller to mitigate the effects of this fault is proposed. The DFIG compliance with various recently released LVRT grid codes under the fire-through fault with and without the STATCOM is examined and compared. Simulation results indicate that fire-through fault has a severe impact on the DFIG voltage profile and the proposed controller is capable of bringing the voltage profile at the point of common coupling (PCC) to the nominal steady state level.

[1]  Han Dong,et al.  Impacts of DFIG-based wind farm on load modeling , 2009, 2009 IEEE Power & Energy Society General Meeting.

[2]  T.A. Haskew,et al.  Analysis of Decoupled d-q Vector Control in DFIG Back-to-Back PWM Converter , 2007, 2007 IEEE Power Engineering Society General Meeting.

[3]  Jos Arrillaga,et al.  High Voltage Direct Current Transmission , 2014 .

[4]  Friedrich W. Fuchs,et al.  Some diagnosis methods for voltage source inverters in variable speed drives with induction machines - a survey , 2003, IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468).

[5]  Lixiang Wei,et al.  Analysis of IGBT Power Cycling Capabilities Used in Doubly Fed Induction Generator Wind Power System , 2011 .

[6]  S Islam,et al.  Application of SMES Unit in Improving the Performance of an AC/DC Power System , 2011, IEEE Transactions on Sustainable Energy.

[7]  P. Student,et al.  Application of SMES to Enhance the Dynamic Performance of DFIG during Voltage Sag and Swell , 2014 .

[8]  A. Abu-Siada,et al.  Application of SMES to Enhance the Dynamic Performance of DFIG During Voltage Sag and Swell , 2012, IEEE Transactions on Applied Superconductivity.

[9]  J. Pedra,et al.  Doubly Fed Induction Generator Subject to Symmetrical Voltage Sags , 2011, IEEE Transactions on Energy Conversion.

[10]  Mohsen Rahimi,et al.  Transient Performance Improvement of Wind Turbines With Doubly Fed Induction Generators Using Nonlinear Control Strategy , 2010, IEEE Transactions on Energy Conversion.

[11]  H.A. Darwish,et al.  Performance of HVDC converter protection during internal faults , 2006, 2006 IEEE Power Engineering Society General Meeting.

[12]  Sherif O. Faried,et al.  Effect of HVDC converter station faults on turbine-generator shaft torsional torques , 1997 .

[13]  P. Musgrove Wind Power , 2010 .

[14]  A. Abu-Siada,et al.  Application of a STATCOM for damping subsynchronous oscillations and transient stability improvement , 2011, AUPEC 2011.

[15]  Shaahin Filizadeh,et al.  Inclusion of robustness into design using optimization-enabled transient simulation , 2005 .

[16]  Yong Kang,et al.  An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults , 2011, IEEE Transactions on Power Electronics.

[17]  K. R. Padiyar 98/00377 Design of reactive current and voltage controller of static condenser , 1997 .

[18]  K. R. Padiyar Hvdc Power Transmission Systems: Technology and System Interactions , 1991 .

[19]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[20]  Olimpo Anaya-Lara,et al.  Ride-through-fault capabilities of DFIG wind farm connected to a VSC station during a DC fault , 2010 .

[21]  M. Khederzadeh Coordination control of statcom and ultc of power transformers , 2007, 2007 42nd International Universities Power Engineering Conference.

[22]  S. Filizadeh,et al.  Inclusion of robustness into design using optimization-enabled transient simulation , 2005, IEEE Transactions on Power Delivery.

[23]  S. M. Islam,et al.  Impacts of Symmetrical and Asymmetrical Voltage Sags on DFIG-Based Wind Turbines Considering Phase-Angle Jump, Voltage Recovery, and Sag Parameters , 2011, IEEE Transactions on Power Electronics.

[24]  Dawei Xiang,et al.  An Industry-Based Survey of Reliability in Power Electronic Converters , 2011, IEEE Transactions on Industry Applications.

[25]  Neville R. Watson,et al.  Flexible power transmission--the HVDC options , 2007 .

[26]  R. Teodorescu,et al.  Overview of recent grid codes for wind power integration , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[27]  Tao Wang,et al.  Transient Thermal Performance of IGBT Power Modules Attached by Low-Temperature Sintered Nanosilver , 2012, IEEE Transactions on Device and Materials Reliability.

[28]  Zhe Chen,et al.  A Review of the State of the Art of Power Electronics for Wind Turbines , 2009, IEEE Transactions on Power Electronics.

[29]  Xin Li,et al.  Short Circuit Current Characteristic of Wind Generators , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[30]  Thomas Ackermann,et al.  Wind Power in Power Systems , 2005 .

[31]  Hong-Hee Lee,et al.  Performance Enhancement of Stand-Alone DFIG Systems With Control of Rotor and Load Side Converters Using Resonant Controllers , 2012, IEEE Transactions on Industry Applications.

[32]  Bin Lu,et al.  A survey of IGBT fault diagnostic methods for three-phase power inverters , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[33]  Lixiang Wei,et al.  Analysis of IGBT power cycling capabilities used in Doubly Fed Induction Generator wind power system , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[34]  Dong-Choon Lee,et al.  A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[35]  A. Abu-Siada,et al.  Damping of subsynchronous oscillations and improve transient stability for wind farms , 2011, 2011 IEEE PES Innovative Smart Grid Technologies.

[36]  Stefan Lundberg,et al.  Energy Efficiency Comparison of Electrical Systems for Wind Turbines , 2002 .

[37]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[38]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..