Transient Stability of Power Grids Comprising Wind Turbines: New Formulation, Implementation, and Application in Real-Time Assessment

Enhancing penetration of wind turbines in the modern power grids, the assessment of the transient stability has changed to a more complicated issue. This paper proposes an innovative real-time method based on the corrected kinetic energy, which aims to assess the transient stability of a power system comprising wind turbines by calculating critical clearing time. To enhance the accuracy of the calculations, the proposed method utilizes structure preserving for taking details of the network model into consideration. Moreover, a new indirect calculation method based on Taylor expansion of the rotor angle is proposed, which considers the effects of the wind turbine generator controllers on the corrected kinetic energy calculation. Specifically, the latter indirect calculations take the effects of the potential terms of transient energy function into account for calculating critical corrected kinetic energy. Also, the latter method considers the fault-on trajectory impact on the transient stability assessment and simultaneously avoids heavy computational burden, and as a result, it guarantees accurate real-time assessment of transient stability. The simulation results show that the proposed method calculates the critical clearing time of wind turbine generators with notable precision and very good speed, and consequently, it is sufficient for transient stability assessment of power grids comprising wind turbines.

[1]  Ruoping Yao,et al.  Three-step impedance criterion for small-signal stability analysis in two-stage DC distributed power systems , 2003 .

[2]  Marta Molinas,et al.  Small-Signal Stability Assessment of Power Electronics Based Power Systems: A Discussion of Impedance- and Eigenvalue-Based Methods , 2017, IEEE Transactions on Industry Applications.

[3]  Ali Reza Seifi,et al.  Sensitivity-based approach for real-time evaluation of transient stability of wind turbines interconnected to power grids , 2018 .

[4]  O. Gomis-Bellmunt,et al.  Modeling and Validation of DFIG 3-MW Wind Turbine Using Field Test Data of Balanced and Unbalanced Voltage Sags , 2011, IEEE Transactions on Sustainable Energy.

[5]  Despoina I. Makrygiorgou,et al.  Modeling and stability of autonomous dc microgrids with converter-controlled energy storage systems , 2017, 2017 IEEE Second International Conference on DC Microgrids (ICDCM).

[6]  Carlos R. Minussi,et al.  Neural network based on adaptive resonance theory with continuous training for multi-configuration transient stability analysis of electric power systems , 2011, Appl. Soft Comput..

[7]  Mohsen Rahimi,et al.  Dynamic behavior and transient stability analysis of fixed speed wind turbines , 2009 .

[8]  B.C. Pal,et al.  Modelling and small-signal analysis of a grid connected doubly-fed induction generator , 2005, IEEE Power Engineering Society General Meeting, 2005.

[9]  Enrico Santi,et al.  Comprehensive Review of Stability Criteria for DC Power Distribution Systems , 2014, IEEE Transactions on Industry Applications.

[10]  H. Jia,et al.  Criterion to evaluate power system online transient stability based on adjoint system energy function , 2015 .

[11]  Gelli Ravikumar,et al.  Taxonomy of PMU Data Based Catastrophic Indicators for Power System Stability Assessment , 2018, IEEE Systems Journal.

[12]  Zhao Yang Dong,et al.  Trajectory sensitivity analysis on the equivalent one-machine-infinite-bus of multi-machine systems for preventive transient stability control , 2015 .

[13]  A Kwasinski,et al.  Dynamic Behavior and Stabilization of DC Microgrids With Instantaneous Constant-Power Loads , 2011, IEEE Transactions on Power Electronics.

[14]  Hsiao-Dong Chiang,et al.  Constructing Analytical Energy Functions for Network-Preserving Power System Models , 2005 .

[15]  F. Blaabjerg,et al.  Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults , 2010, IEEE Transactions on Power Electronics.

[16]  Mansour Tabari,et al.  A Mathematical Model for Stability Analysis of a DC Distribution System for Power System Integration of Plug-In Electric Vehicles , 2015, IEEE Transactions on Vehicular Technology.

[17]  Nilanjan Senroy,et al.  Critical clearing time estimation using synchrophasor data-based equivalent dynamic model , 2015 .

[18]  Madeleine Gibescu,et al.  Large-signal stability analysis of two power converters solutions for DC shipboard microgrid , 2017, 2017 IEEE Second International Conference on DC Microgrids (ICDCM).

[19]  Reza Ahmadi,et al.  Improving the Performance of a Line Regulating Converter in a Converter-Dominated DC Microgrid System , 2014, IEEE Transactions on Smart Grid.

[20]  P. Ledesma,et al.  Doubly fed induction generator model for transient stability analysis , 2005, IEEE Transactions on Energy Conversion.

[21]  Zhe Chen,et al.  Analysis and estimation of transient stability for a grid-connected wind turbine with induction generator , 2011 .

[22]  Bo Wang,et al.  Power System Transient Stability Assessment Based on Big Data and the Core Vector Machine , 2016, IEEE Transactions on Smart Grid.

[23]  F. Milano,et al.  An open source power system analysis toolbox , 2005, 2006 IEEE Power Engineering Society General Meeting.

[24]  Elias Kyriakides,et al.  Dynamic IEEE Test Systems for Transient Analysis , 2017, IEEE Systems Journal.

[25]  Konstantin Turitsyn,et al.  Stability and control of ad hoc dc microgrids , 2016, 2016 IEEE 55th Conference on Decision and Control (CDC).

[26]  T. S. Chung,et al.  Transient stability limit conditions analysis using a corrected transient energy function approach , 2000 .

[27]  Udaya Annakkage,et al.  Support vector machine-based algorithm for post-fault transient stability status prediction using synchronized measurements , 2011, 2011 IEEE Power and Energy Society General Meeting.

[28]  Thanh Long Vu,et al.  Lyapunov Functions Family Approach to Transient Stability Assessment , 2014, IEEE Transactions on Power Systems.

[29]  A. Mullane,et al.  Modeling of the wind turbine with a doubly fed induction generator for grid integration studies , 2006, IEEE Transactions on Energy Conversion.

[30]  Shahram Montaser Kouhsari,et al.  A novel recursive approach for real-time transient stability assessment based on corrected kinetic energy , 2016, Appl. Soft Comput..

[31]  Thanh Long Vu,et al.  Toward Simulation-Free Estimation of Critical Clearing Time , 2016, IEEE Transactions on Power Systems.

[32]  Alan R. Champneys,et al.  Analytical Approximations of Critical Clearing Time for Parametric Analysis of Power System Transient Stability , 2015, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[33]  Nayeem Rahmat Ullah,et al.  Effect of operational modes of a wind farm on the transient stability of nearby generators and on power oscillations: a Nordic grid study , 2008 .

[34]  Babak Fahimi,et al.  Stability Assessment of a DC Distribution Network in a Hybrid Micro-Grid Application , 2014, IEEE Transactions on Smart Grid.

[35]  M. Z. Jahromi,et al.  A high-precision real-time approach to calculate closest unstable equilibrium points , 2017 .

[36]  Vladislav Akhmatov,et al.  Modelling and ride‐through capability of variable speed wind turbines with permanent magnet generators , 2006 .

[37]  Z.X. Cai,et al.  Transient stability analysis of AC/DC power system based on transient energy function , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[38]  Rui Zhang,et al.  Post-disturbance transient stability assessment of power systems by a self-adaptive intelligent system , 2015 .

[39]  P. Kundur,et al.  Power system stability and control , 1994 .

[40]  M. A. Chowdhury,et al.  Comparative study on fault responses of synchronous generators and wind turbine generators using transient stability index based on transient energy function , 2013 .

[41]  U. D. Annakkage,et al.  Prediction of the Transient Stability Boundary Using the Lasso , 2013, IEEE Transactions on Power Systems.