The effect of radial head excision and arthroplasty on elbow kinematics and stability.

BACKGROUND Radial head fractures are common injuries. Comminuted radial head fractures often are treated with radial head excision with or without radial head arthroplasty. The purpose of the present study was to determine the effect of radial head excision and arthroplasty on the kinematics and stability of elbows with intact and disrupted ligaments. We hypothesized that elbow kinematics and stability would be (1) altered after radial head excision in elbows with intact and disrupted ligaments, (2) restored after radial head arthroplasty in elbows with intact ligaments, and (3) partially restored after radial head arthroplasty in elbows with disrupted ligaments. METHODS Eight cadaveric upper extremities were studied in an in vitro elbow simulator that employed computer-controlled actuators to govern tendon-loading. Testing was performed in stable, medial collateral ligament-deficient, and lateral collateral ligament-deficient elbows with the radial head intact, with the radial head excised, and after radial head arthroplasty. Valgus angulation and rotational kinematics were determined during passive and simulated active motion with the arm dependent. Maximum varus-valgus laxity was measured with the arm in a gravity-loaded position. RESULTS In specimens with intact ligaments, elbow kinematics were altered and varus-valgus laxity was increased after radial head excision and both were corrected after radial head arthroplasty. In specimens with disrupted ligaments, elbow kinematics were altered after radial head excision and were similar to those observed in specimens with a native radial head after radial head arthroplasty. Varus-valgus laxity was increased after ligament disruption and was further increased after radial head excision. Varus-valgus laxity was corrected after radial head arthroplasty and ligament repair; however, it was not corrected after radial head arthroplasty without ligament repair. CONCLUSIONS Radial head excision causes altered elbow kinematics and increased laxity. The kinematics and laxity of stable elbows after radial head arthroplasty are similar to those of elbows with a native radial head. However, radial head arthroplasty alone may be insufficient for the treatment of complex fractures that are associated with damage to the collateral ligaments as arthroplasty alone does not restore stability to elbows with ligament injuries.

[1]  R. Hotchkiss Displaced Fractures of the Radial Head: Internal Fixation or Excision? , 1997, The Journal of the American Academy of Orthopaedic Surgeons.

[2]  E. Wallenböck,et al.  Resection of the radial head: an alternative to use of a prosthesis? , 1997, The Journal of trauma.

[3]  H. Schubert Radial head fracture. , 2000, Canadian family physician Medecin de famille canadien.

[4]  James A. Johnson,et al.  Metallic radial head arthroplasty improves valgus stability of the elbow. , 1999, Clinical orthopaedics and related research.

[5]  James A. Johnson,et al.  Muscle Forces and Pronation Stabilize the Lateral Ligament Deficient Elbow , 2001, Clinical orthopaedics and related research.

[6]  G. King,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[7]  C E Dunning,et al.  Simulation of elbow and forearm motion in vitro using a load controlled testing apparatus. , 2000, Journal of biomechanics.

[8]  B. Morrey,et al.  Results of delayed excision of the radial head after fracture. , 1986, The Journal of bone and joint surgery. American volume.

[9]  B. Morrey,et al.  Chronic posterior subluxation and dislocation of the radial head. , 1991, The Journal of bone and joint surgery. American volume.

[10]  D. Ring,et al.  Open reduction and internal fixation of fractures of the radial head. , 2004, Hand clinics.

[11]  B F Morrey,et al.  Contribution of Monoblock and Bipolar Radial Head Prostheses to Valgus Stability of the Elbow , 2001, The Journal of bone and joint surgery. American volume.

[12]  James A. Johnson,et al.  Rehabilitation of the medial collateral ligament-deficient elbow: an in vitro biomechanical study. , 2000, The Journal of hand surgery.

[13]  Dennis R. Wenger,et al.  The Elbow and its Disorders , 1986 .

[14]  J. O. Søjbjerg,et al.  Elbow joint kinematics after excision of the radial head. , 1999, Journal of shoulder and elbow surgery.

[15]  James A. Johnson,et al.  Simulated active control produces repeatable motion pathways of the elbow in an in vitro testing system. , 2001, Journal of biomechanics.

[16]  James A. Johnson,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[17]  B F Morrey,et al.  Valgus stability of the elbow. A definition of primary and secondary constraints. , 1991, Clinical orthopaedics and related research.

[18]  A. Weiland,et al.  Valgus stability of the elbow , 1987, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.