Microfabrication of new microelectrode arrays equipped with a ground surface configuration for focal neural microstimulation

Extracellular electrical stimulation of the central nervous system has been used empirically for decades, with both fundamental and clinical goals. Currently, microelectrode arrays (MEAs) offer new possibilities for CNS microstimulation, allowing in principle to activate only neurons located in the vicinity of the stimulation sites. To overcome the lack of focality of monopolar stimulations, multipolar approaches are commonly used, multiplying therefore the number of electrodes of the arrays and the complexity of the connection system behind. To overcome these limitations, we developed a ground surface configuration consisting in surrounding all the electrodes with a conductive surface laying over the MEA substrate, and using it for the stimulation current return. We first report the microfabrication of a prototype of MEA equipped with this configuration. We also perform experimental recordings of the potential field induced by microstimulations and confirm the expected increased focality with the ground surface configuration. This will open the way to focal 'pixel-like' microstimulation of neural networks using MEAs.

[1]  J. Rauschecker,et al.  Sending Sound to the Brain , 2002, Science.

[2]  E. Zrenner Will Retinal Implants Restore Vision ? , 2002 .

[3]  M. Brecht,et al.  Behavioural report of single neuron stimulation in somatosensory cortex , 2008, Nature.

[4]  W. Theodore Brain stimulation for epilepsy , 2005, Nature Clinical Practice Neurology.

[5]  K. Svoboda,et al.  Sparse optical microstimulation in barrel cortex drives learned behaviour in freely moving mice , 2008, Nature.

[6]  Malini Narayanan Nadig Development of a silicon retinal implant: cortical evoked potentials following focal stimulation of the rabbit retina with light and electricity , 1999, Clinical Neurophysiology.

[7]  Arthur Prochazka,et al.  Control of urinary bladder function with devices: successes and failures. , 2006, Progress in brain research.

[8]  C. Winfree,et al.  Spinal cord stimulation for the relief of chronic pain. , 2005, Current surgery.

[9]  O. Billoint,et al.  A 64-Channel ASIC for In-Vitro Simultaneous Recording and Stimulation of Neurons using Microelectrode Arrays , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Sébastien Joucla,et al.  Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study , 2009, PloS one.

[11]  J. Rizzo,et al.  Multi-electrode stimulation and recording in the isolated retina , 2000, Journal of Neuroscience Methods.

[12]  E. Perl,et al.  Microelectrode arrays for stimulation of neural slice preparations , 1997, Journal of Neuroscience Methods.

[13]  A. Benabid,et al.  Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus , 1991, The Lancet.

[14]  Anja Boisen,et al.  Investigation of the bond strength between the photo-sensitive polymer SU-8 and gold , 2005 .

[15]  Joseph F Rizzo,et al.  In vivo electrical stimulation of rabbit retina with a microfabricated array: strategies to maximize responses for prospective assessment of stimulus efficacy and biocompatibility. , 2004, Restorative neurology and neuroscience.

[16]  B. Wheeler,et al.  Multisite hippocampal slice recording and stimulation using a 32 element microelectrode array , 1988, Journal of Neuroscience Methods.