Personalized sedation level monitoring in ICU patients using heart rate variability

Aim: To develop an automated system to monitor sedation levels in intensive care unit patients using heart rate variability (HRV). Methods: We developed an automatic sedation level prediction system using HRV as input to a support vector machine learning algorithm. Our data consisted of electrocardiogram recordings from a heterogeneous group of 50 mechanically ventilated adults receiving sedatives in an ICU setting. The target variable was the Richmond agitation-sedation scale score, grouped into four levels: “comatose” (−5), “deeply sedated” (−4 to −3), “lightly sedated” (−2 to 0), and “agitated” (+1 to +4). As input we used 14 features derived from the normalized-RR (NN) interval. We used leave-one-subject-out cross-validated accuracy to measure system performance. Results: A patient-independent version of the proposed system discriminated between the 4 sedation levels with an overall accuracy of 52%. A patient-specific version, where the training data was supplemented with the patient's labeled HRV epochs from the preceding 24 hours, improved classification accuracy to 60%. Conclusions: Our preliminary results suggest that the HRV varies systematically with sedation levels and has potential to supplement current clinical sedation level assessment methods. With additional variables such as disease pathology, and pharmacological data, the proposed system could lead to a fully automated system for depth of sedation monitoring.

[1]  R. Arbour Impact of bispectral index monitoring on sedation and outcomes in critically ill adults: a case series. , 2006, Critical care nursing clinics of North America.

[2]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[3]  C. Sessler,et al.  The Richmond Agitation-Sedation Scale: validity and reliability in adult intensive care unit patients. , 2002, American journal of respiratory and critical care medicine.

[4]  T. Walsh,et al.  An assessment of the validity of spectral entropy as a measure of sedation statein mechanically ventilated critically ill patients , 2008, Intensive Care Medicine.

[5]  G. Guyatt,et al.  Using and understanding sedation scoring systems: a systematic review , 2000, Intensive Care Medicine.

[6]  Pere Caminal,et al.  Detrended Fluctuation Analysis of EEG as a Measure of Depth of Anesthesia , 2007, IEEE Transactions on Biomedical Engineering.

[7]  M. F. Mascia,et al.  Pharmacoeconomic impact of rational use guidelines on the provision of analgesia, sedation, and neuromuscular blockade in critical care , 2000, Critical care medicine.

[8]  J. Sleigh,et al.  Analysis of depth of anesthesia with Hilbert–Huang spectral entropy , 2008, Clinical Neurophysiology.

[9]  Laalitha Surapaneni,et al.  Daily Interruption of Sedative Infusions in Critically Ill Patients Undergoing Mechanical Ventilation , 2015 .

[10]  S. Gottfried,et al.  Incidence, risk factors and consequences of ICU delirium , 2006, Intensive Care Medicine.

[11]  J. Devlin The pharmacology of oversedation in mechanically ventilated adults , 2008, Current opinion in critical care.

[12]  David W. Zhou,et al.  Automatic Classification of Sedation Levels in ICU Patients Using Heart Rate Variability , 2016, Critical care medicine.

[13]  S. McGrane,et al.  Sedation in the intensive care unit. , 2012, Minerva anestesiologica.

[14]  L. Tarassenko,et al.  Characterizing artefact in the normal human 24-hour RR time series to aid identification and artificial replication of circadian variations in human beat to beat heart rate using a simple threshold , 2002, Computers in Cardiology.