Surfactant effects on α-factors in aeration systems

ABSTRA C T Aeration in wastewater treatment processes accounts for the largest fraction of plant energy costs. Aeration systems function by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactant accumulation on gas‐liquid interfaces reduces mass transfer rates, and this reduction in general is larger for fine-bubble aerators. This study evaluates mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes show higher gas transfer depression for lower turbulence regimes. Contamination effects can be offset at the expense of operating efficiency, which is characteristic of surface aerators and coarsebubble diffusers. Results describe the variability of a-factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations describing mass transfer as a function of physiochemical and geometrical characteristics of the aeration process.

[1]  E. Gloyna Advances in water quality improvement , 1968 .

[2]  Ferri,et al.  Which surfactants reduce surface tension faster? A scaling argument for diffusion-controlled adsorption , 2000, Advances in colloid and interface science.

[3]  Asce,et al.  Measurement of Oxygen Transfer in Clean Water , 1993 .

[4]  M. Stenstrom,et al.  DYNAMIC SURFACE TENSION EFFECTS ON OXYGEN TRANSFER , 1991 .

[5]  E. Barnhart,et al.  The effect of organic substances on the transfer of oxygen from air bubbles in water , 1961 .

[6]  N. Frossling,et al.  Uber die Verdunstung fallender Tropfen , 1938 .

[7]  L. Tordai,et al.  Time‐Dependence of Boundary Tensions of Solutions I. The Role of Diffusion in Time‐Effects , 1946 .

[8]  F. H. Garner,et al.  Circulation inside gas bubbles , 1954 .

[9]  Marko Zlokarnik,et al.  Scale-Up in Chemical Engineering: Second, Completely Revised and Extended Edition , 2002 .

[10]  Michael K. Stenstrom,et al.  Effects of alpha, beta and theta factor upon the design, specification and operation of aeration systems , 1981 .

[11]  J. Bersillon,et al.  Bubble-free aeration using membranes: mass transfer analysis , 1989 .

[12]  S. Duke,et al.  Visualization of oxygen concentration fields and measurement of concentration gradients at bubble surfaces in surfactant-contaminated water , 2004 .

[13]  R. Clift,et al.  Bubbles, Drops, and Particles , 1978 .

[14]  David J. Reardon,et al.  Turning Down the Power , 1995 .

[15]  M K Stenstrom,et al.  Fifteen Years of Offgas Transfer Efficiency Measurements on Fine‐Pore Aerators: Key Role of Sludge Age and Normalized Air Flux , 2005, Water environment research : a research publication of the Water Environment Federation.

[16]  Michael K Stenstrom,et al.  Economic Implications of Fine‐Pore Diffuser Aging , 2006, Water environment research : a research publication of the Water Environment Federation.