Three‐dimensional MR imaging of the coronary arteries: Preliminary clinical experience

A three‐dimensional (3D) magnetization‐prepared (MP) rapid gradient‐echo (RAGE) and 3D RAGE technique was used to image the coronary arteries in healthy volunteers and patients with known disease. Each sequence produced images of volumes partitioned into 16 thin sections with differing blood‐fat‐myocardium contrast. The two types of images were subtracted to null fat signal, thus producing a third image set that showed flowing blood. Total imaging time was about 17 minutes. In the volunteers, the 3D MP‐RAGE and subtraction images consistently showed the morphology of the right coronary artery. The left main and left anterior descending arteries were also well seen. The circumflex artery was less consistently identified. Of the 17 diseased coronary artery segments identified at catheterization, 16 had altered signal intensity (narrowing, occlusion, reduced contrast‐to‐noise ratio, irregularity) on the subtraction images, while 13 had altered signal intensity on the 3D MP‐RAGE images. The results indicate that this 3D MP‐RAGE and 3D RAGE technique has potential utility as a screening method for coronary heart disease.

[1]  D. Burstein,et al.  MR imaging of coronary artery flow in isolated and in vivo hearts , 1991, Journal of magnetic resonance imaging : JMRI.

[2]  D Chien,et al.  Advances in cardiac applications of subsecond flash MRI. , 1990, Magnetic resonance imaging.

[3]  J S Lewin,et al.  Three-dimensional time-of-flight MR angiography: applications in the abdomen and thorax. , 1991, Radiology.

[4]  P. Wielopolski,et al.  Three-dimensional MR imaging of the pulmonary vasculature: preliminary experience. , 1992, Radiology.

[5]  E. Haacke,et al.  Pseudo‐gating: Elimination of periodic motion artifacts in magnetic resonance imaging without gating , 1987, Magnetic resonance in medicine.

[6]  R S Balaban,et al.  Magnetization transfer contrast in MR imaging of the heart. , 1991, Radiology.

[7]  J. Ross,et al.  Intracranial circulation: preliminary clinical results with three-dimensional (volume) MR angiography. , 1989, Radiology.

[8]  R. Edelman,et al.  Coronary arteries: breath-hold MR angiography. , 1991, Radiology.

[9]  Weili Lin,et al.  A fast, iterative, partial-fourier technique capable of local phase recovery , 1991 .

[10]  M. L. Wood,et al.  Spoiling of transverse magnetization in steady‐state sequences , 1991, Magnetic resonance in medicine.

[11]  T J Masaryk,et al.  Magnetic resonance angiography of the extracranial carotid arteries and intracranial vessels , 1989, Neurology.

[12]  R. Körfer,et al.  Measurement of systolic and diastolic flow rates in the coronary artery system by x-ray densitometry. , 1983, Circulation.

[13]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[14]  C L Dumoulin,et al.  A method of coronary MR angiography. , 1991, Journal of computer assisted tomography.

[15]  J. Mugler,et al.  Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE) , 1990, Magnetic resonance in medicine.

[16]  Z H Cho,et al.  NMR angiography of coronary vessels with 2‐D planar image scanning , 1991, Magnetic resonance in medicine.

[17]  D Henrich,et al.  3D-snapshot flash NMR imaging of the human heart. , 1990, Magnetic resonance imaging.

[18]  Bob S. Hu,et al.  Coronary angiography using fast selective inversion recovery , 1991, Magnetic resonance in medicine.