Improving the performance of booster heat pumps using zeotropic mixtures

Abstract This study demonstrated an increase in the thermodynamic performance of a booster heat pump, which was achieved by choosing the working fluid among pure and mixed fluids. The booster heat pump was integrated in an ultra-low-temperature district heating network with a forward temperature of 40 °C to produce domestic hot water, by heating part of the forward stream to 60 °C, while cooling the remaining part to the return temperature of 25 °C. The screening of working fluids considered 18 pure working fluids and all possible binary mixtures of these fluids. The most promising solutions were analysed with respect to their performance under off-design conditions and their economic potential. The best-performing mixture showed a coefficient of performance (COP) of 9.0 and thereby outperformed R134a by 47%. Although the mixed working fluids resulted in higher investment cost, the economic performance was comparable to the pure fluids. The mixtures showed similar performance as the pure fluids at off-design conditions. It was concluded that the mixtures 50% Propylene/50% Butane and 50% R1234yf/50% R1233zd(E) could considerably improve the thermodynamic performance of the overall heat supply system while being economically competitive to pure fluids.

[1]  Brian Elmegaard,et al.  Analysis of temperature glide matching of heat pumps with zeotropic working fluid mixtures for different temperature glides , 2018 .

[2]  J. Thome,et al.  Convective Boiling and Condensation , 1972 .

[3]  S. Koyama,et al.  Low GWP refrigerants R1234ze(E) and R1234ze(Z) for high temperature heat pumps , 2014 .

[4]  Benedick Montreal Protocol on Substances that Deplete the Ozone Layer , 1996 .

[5]  Unfccc Kyoto Protocol to the United Nations Framework Convention on Climate Change , 1997 .

[6]  Ralf-Roman Schmidt,et al.  Low temperature district heating in Austria: Energetic, ecologic and economic comparison of four case studies , 2016 .

[7]  Brian Vad Mathiesen,et al.  4th Generation District Heating (4GDH) Integrating smart thermal grids into future sustainable energy systems , 2014 .

[8]  A. Zoughaib,et al.  Exergy Based Methodology for Optimized Integration of Heat Pumps in Industrial Processes , 2014 .

[9]  Brian Elmegaard,et al.  Technical and economic working domains of industrial heat pumps: Part 2 – Ammonia-water hybrid absorption-compression heat pumps☆ , 2015 .

[10]  B. Elmegaard,et al.  Integration of space heating and hot water supply in low temperature district heating , 2016 .

[11]  Brian Elmegaard,et al.  Low Temperature District Heating Consumer Unit with Micro Heat Pump for Domestic Hot Water Preparation , 2012 .

[12]  Brian Elmegaard,et al.  High Temperature Heat Pump Integration using Zeotropic Working Fluids for Spray Drying Facilities , 2017 .

[13]  Brian Elmegaard,et al.  Performance of ultra low temperature district heating systems with utility plant and booster heat pumps , 2017 .

[14]  Svend Svendsen,et al.  Alternative solutions for inhibiting Legionella in domestic hot water systems based on low-temperature district heating , 2016 .

[15]  Onu Environnement,et al.  Handbook for the Montreal Protocol on Substances that Deplete the Ozone Layer. , 2009 .

[16]  S. Jayaraj,et al.  A review on recent developments in new refrigerant mixtures for vapour compression‐based refrigeration, air‐conditioning and heat pump units , 2011 .

[17]  Brian Elmegaard,et al.  Lowering district heating temperatures – Impact to system performance in current and future Danish energy scenarios , 2016 .

[18]  Rasmus Søgaard Lund,et al.  Comparison of Low-temperature District Heating Concepts in a Long-Term Energy System Perspective , 2017 .

[19]  Brian Elmegaard,et al.  Heat pumps in combined heat and power systems , 2014 .

[20]  S. Madronich,et al.  Sources, fates, toxicity, and risks of trifluoroacetic acid and its salts: Relevance to substances regulated under the Montreal and Kyoto Protocols , 2016, Journal of toxicology and environmental health. Part B, Critical reviews.

[21]  H. Auracher Thermal design and optimization , 1996 .

[22]  Reinhard Radermacher,et al.  Vapor compression heat pumps with refrigerant mixtures , 2005 .

[23]  Stella Papasavva,et al.  Ozone and TFA impacts in North America from degradation of 2,3,3,3-Tetrafluoropropene (HFO-1234yf), a potential greenhouse gas replacement. , 2010, Environmental science & technology.

[24]  Vincent Lemort,et al.  Pure and Pseudo-pure Fluid Thermophysical Property Evaluation and the Open-Source Thermophysical Property Library CoolProp , 2014, Industrial & engineering chemistry research.

[25]  Brian Elmegaard,et al.  Mapping of low temperature heat sources in Denmark , 2015 .

[26]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 8.0 , 2007 .

[27]  Reinhard Radermacher,et al.  LCCP evaluation on various vapor compression cycle options and low GWP refrigerants , 2016 .

[28]  Anders N. Andersen,et al.  Booster heat pumps and central heat pumps in district heating , 2016 .

[29]  B. Elmegaard,et al.  Improving efficiency of heat pumps by use of zeotropic mixtures for different temperature glides , 2017 .

[30]  M. J. Moran,et al.  Thermal design and optimization , 1995 .