Image Quality Improvement and Memory-Saving in a Permanent-Magnet-Array-Based MRI System

Point-of-care magnetic resonance imaging (MRI) requires clear images within a short scanning time, a small footprint of the scanner, and relatively low memory required for image reconstruction. A permanent magnet array (PMA)-based MRI system is a good candidate to supply a magnetic field due to its compactness and low power consumption. However, it has relatively inhomogeneous magnetic field and thus non-linear gradients, which results in location-dependent k-spaces (so called local k-spaces) and uneven signal point populations in the local k-spaces, compromising the image quality. Moreover, owing to the non-linearity, imaging reconstruction using Fourier transform does not work, which leads to an increase in the required computation memory. In this study, in order to improve the image quality, the approaches of compensating the uneven signal point population by increasing the numbers of sampling points or rotation angles are investigated in terms of their impacts on image quality improvement, acquisition time, image reconstruction time, and memory consumption. Both methods give a significant improvement on image image quality although they result in a large and dense encoding matrix and thus a large memory consumption. To lower the memory consumption, it is further proposed to transform such a matrix to frequency domain where the matrix could be sparse. Moreover, a row-wise truncation to the transformed encoding matrix is applied to further reduce the memory consumption. Through the results of numerical experiments, it is shown that the required memory for calculation can effectively be reduced by 71.6% while the image becomes clearer by increasing the number of sampling point and/or the number of rotation angles. With the successful demonstration where improved image quality and a lowered memory required can be obtained simultaneously, the proposed study is one step forward for a PMA-based MRI system towards its targeted point-of-care application scenario.

[1]  Bernhard Blümich,et al.  The NMR MOUSE, a Mobile Universal Surface Explorer , 1996 .

[2]  Maxim Zaitsev,et al.  Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields , 2010, Magnetic resonance in medicine.

[3]  Lawrence L. Wald,et al.  Design of Sparse Halbach Magnet Arrays for Portable MRI Using a Genetic Algorithm , 2018, IEEE Transactions on Magnetics.

[4]  Maxim Zaitsev,et al.  Reconstruction of MRI data encoded by multiple nonbijective curvilinear magnetic fields , 2012, Magnetic resonance in medicine.

[5]  Maxim Zaitsev,et al.  Practical considerations for in vivo MRI with higher dimensional spatial encoding , 2012, Magnetic Resonance Materials in Physics, Biology and Medicine.

[6]  Tomoyuki Haishi,et al.  Development of a mobile magnetic resonance imaging system for outdoor tree measurements. , 2011, The Review of scientific instruments.

[7]  Robin Dykstra,et al.  Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays , 2018, Investigative Magnetic Resonance Imaging.

[8]  A. Haase,et al.  Portable nuclear magnetic resonance imaging system , 2000 .

[9]  Rob F. Remis,et al.  Conjugate gradient variants for $${\ell}_{p}$$ℓp-regularized image reconstruction in low-field MRI , 2019 .

[10]  Oliver Speck,et al.  Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[11]  Zhi Hua Ren,et al.  Design and Optimization of a Ring-Pair Permanent Magnet Array for Head Imaging in a Low-Field Portable MRI System , 2019, IEEE Transactions on Magnetics.

[12]  Maxim Zaitsev,et al.  Radial Imaging With Multipolar Magnetic Encoding Fields , 2011, IEEE Transactions on Medical Imaging.

[13]  Shao Ying Huang,et al.  Effects of Encoding Fields of Permanent Magnet Arrays on Image Quality in Low-Field Portable MRI Systems , 2019, IEEE Access.

[14]  Gigi Galiana,et al.  O‐space imaging: Highly efficient parallel imaging using second‐order nonlinear fields as encoding gradients with no phase encoding , 2010, Magnetic resonance in medicine.

[15]  Yasuhiko Terada,et al.  Development of a small car-mounted magnetic resonance imaging system for human elbows using a 0.2 T permanent magnet. , 2019, Journal of magnetic resonance.

[16]  Shao Ying Huang,et al.  An Irregular-Shaped Inward-Outward Ring-Pair Magnet Array With a Monotonic Field Gradient for 2D Head Imaging in Low-Field Portable MRI , 2019, IEEE Access.

[17]  Maxim Zaitsev,et al.  MR image reconstruction from generalized projections , 2014, Magnetic resonance in medicine.

[18]  Maxim Zaitsev,et al.  Simultaneously driven linear and nonlinear spatial encoding fields in MRI , 2011, Magnetic resonance in medicine.