Film-Type Sensor Materials PVDF and EMFi in Measurement of Cardiorespiratory Signals— A Review

In this paper, some recent results obtained with film-type sensor materials polyvinylidenefluoride (PVDF) and electromechanical film (EMFi) are presented. The materials generate a voltage when they are mechanically deformed, however, because of their capacitive nature only the change of an external force can be measured. Hence, the sensors made of these materials are useful especially in the measurements of physiological pulsatile signals (e.g., heart rate and respiration). The entire measurement process with the PVDF and EMFi sensors is considered here; from the design and construction of the sensors and measurement electronics to the analysis of the measured data. The paper also presents some examples of the physiological signals (heart rate, respiration, and heart sounds) measured with the PVDF and EMFi sensors. Flexible and thin sensor materials are useful especially in physiological applications where the sensor is integrated into clothing or into daily life objects (e.g., a chair or a bed). The sensor attachments to human can be minimized and the measurement systems can be designed to be unobtrusive and comfortable for the user.

[1]  M. Tavel,et al.  Spectral analysis of heart sounds: relationships between some physical characteristics and frequency spectra of first and second heart sounds in normals and hypertensives. , 1984, Journal of biomedical engineering.

[2]  Daming Wei,et al.  Real-Time Monitoring of Respiration Rhythm and Pulse Rate During Sleep , 2006, IEEE Transactions on Biomedical Engineering.

[3]  Jouko Siivola,et al.  Non-invasive piezoelectric transducer for recording of at the level of diaphragm , 1998 .

[4]  Alpo Värri,et al.  Towards a heart disease diagnosing system based on force sensitive chair's measurement, biorthogonal wavelets and neural networks , 2007, Eng. Appl. Artif. Intell..

[5]  O. Postolache,et al.  Vital Signs Monitoring System Based on EMFi Sensors and Wavelet Analysis , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.

[6]  H. Schmidt,et al.  Piezoelectric polymer electrets , 1996 .

[7]  A Värri,et al.  Ballistocardiography in sitting and horizontal positions , 2008, Physiological measurement.

[8]  Zhongwei Jiang,et al.  A novel wearable sensor device with conductive fabric and PVDF film for monitoring cardiorespiratory signals , 2006 .

[9]  Guang-Zhong Yang,et al.  Body sensor networks , 2006 .

[10]  B.H. Jansen,et al.  Monitoring of the ballistocardiogram with the static charge sensitive bed , 1991, IEEE Transactions on Biomedical Engineering.

[11]  J. Lekkala,et al.  Measurement of heart sounds with EMFi transducer , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  J. Siivola,et al.  New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements , 1989, Medical and Biological Engineering and Computing.

[13]  J.L. Jacobs,et al.  Characterization of a novel heart and respiratory rate sensor , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  A. J. Zuckerwar,et al.  Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor , 1993, IEEE Transactions on Biomedical Engineering.

[15]  M. Paajanen The cellular polypropylene electret material. Electromechanical properties: Dissertation , 2001 .

[16]  Emmanuel Ifeachor,et al.  Digital Signal Processing: A Practical Approach , 1993 .

[17]  Jukka Lekkala,et al.  Modelling the electromechanical film (EMFi) , 2000 .

[18]  A. Lanata,et al.  New Ultrasound-Based Wearable System for Cardiac Monitoring , 2006, 2006 5th IEEE Conference on Sensors.

[19]  Alparslan Demirel,et al.  Recent developments and trends in biomedical sensors , 2005 .

[20]  E. Alasaarela,et al.  Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor , 2006, Proceedings of the 2006 IEEE Sensors Applications Symposium, 2006..

[21]  Satu Kärki,et al.  Film-type Sensor Materials in Measurement of Physiological Force and Pressure Variables , 2009 .

[22]  J. Siivola,et al.  ETMF-polymer transducer as a detector of respiration in humans , 1993, Medical and Biological Engineering and Computing.

[23]  Jukka Lekkala,et al.  ElectroMechanical Film (EMFi) — a new multipurpose electret material , 2000 .

[24]  Shang-Fei Hu,et al.  Pulse wave sensor for non-intrusive driver's drowsiness detection , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  R. S. Anand PC based monitoring of human heart sounds , 2005, Comput. Electr. Eng..

[26]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[27]  Yoshihito Osada,et al.  Polymer sensors and actuators , 2000 .

[28]  Jukka Lekkala,et al.  MATERIAL AND OPERATIONAL PROPERTIES OF LARGE-AREA MEMBRANE TYPE SENSORS FOR SMART ENVIRONMENTS , 2003 .

[29]  Yong Gyu Lim,et al.  Mechanocardiogram Measured at the Back of Subjects Sitting in a Chair as a Non-intrusive Pre-ejection Period Measurement , 2006, 2006 Pervasive Health Conference and Workshops.

[30]  J. Bendat,et al.  Random Data: Analysis and Measurement Procedures , 1971 .

[31]  D. S. Luciano,et al.  Human Physiology: The Mechanism of Body Function , 1975 .

[32]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[33]  A. Akhbardeh,et al.  An EMFi-film sensor based ballistocardiographic chair: performance and cycle extraction method , 2005, IEEE Workshop on Signal Processing Systems Design and Implementation, 2005..

[34]  Hershel Raff,et al.  Human Physiology: The Mechanisms of Body Function , 2006 .

[35]  Alpo Värri,et al.  Automatic detection of spiking events in EMFi sheet during sleep. , 2006, Medical engineering & physics.

[36]  Yuquan Chen,et al.  A piezopolymer finger pulse and breathing wave sensor , 1990 .

[37]  Hannu Sorvoja,et al.  Use of EMFi as a blood pressure pulse transducer , 2005, IEEE Transactions on Instrumentation and Measurement.

[38]  J. Dripps,et al.  A transducer for detecting foetal breathing movements using PVDF film. , 1993, Physiological measurement.

[39]  Aleksandra M. Vinogradov,et al.  Piezoelectricity in Polymers , 2002 .

[40]  Izumi Nishidate,et al.  Unconstrained cardiorespiratory and body movement monitoring system for home care , 2005, Medical and Biological Engineering and Computing.

[41]  Myeong-Chan Cho,et al.  Wireless Biomedical Signal Monitoring Device on Wheelchair using Noncontact Electro-mechanical Film Sensor , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[42]  J. Lekkala,et al.  A new method to measure heart rate with EMFi and PVDF materials , 2009, Journal of medical engineering & technology.

[43]  B. J. Kirby,et al.  Clinical examination of the heart , 2002 .

[44]  A Värri,et al.  Ballistocardiogaphic studies with acceleration and electromechanical film sensors. , 2009, Medical engineering & physics.

[45]  A. Varri,et al.  A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[46]  Jukka Lekkala,et al.  Film-type transducer materials PVDF and EMFi in the measurement of heart and respiration rates , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.