Clinical Accuracy of Computer-Assisted Two-Dimensional Fluoroscopy for the Percutaneous Placement of Lumbosacral Pedicle Screws

Study Design. Clinical case series. Objective. The primary objective of this study was to evaluate the clinical accuracy of computer-assisted two-dimensional fluoroscopy (2D-CAS) for the percutaneous placement of lumbosacral pedicle screws. Summary of Background Data. Loss of visual anatomic landmarks and reduced tactile feedback increases the risk of pedicle screw misplacement by when using minimally invasive (MIS) percutaneous techniques. However, objective data on screw misplacement in this scenario is lacking. Methods. A MIS-2D-CAS technique (FluoroNav) was used for the placement of pedicle screws in 41 consecutive patients undergoing MIS—interbody instrumented fusion. Postoperative computerized tomography (CT) was obtained in all patients at 6 months after surgery and was evaluated by 3 observers. The relative position of the screw to the pedicle was graded regarding pedicle breach (I, no breach; II, <2 mm; III, 2–4 mm; IV, >4 mm), breach direction, vertebral body perforation and screw trajectory. Interobserver reliability of CT grading was assessed with kappa statistics. Results. A total of 161 screws were placed. No neurologic, vascular, or visceral injuries occurred. About 37 (23%) screws breached the pedicle. The majority (83.8%, 31/37) of breaches were graded II. There were 5 Grade III and 1 Grade IV breaches. Medial versus lateral breaches occurred in 30% (11/37) and 60% (22/37), respectively; 10% (4/37) of the breaches were superior. Overall, 8 (5%) vertebral body breaches occurred. Of the pedicle screws, 19 (12%) had trajectories that deviated from acceptable, with the majority being medial (16/19, 84%). Fluoroscopy time for screw placement was typically less than 20 seconds total per case. There was 1 clinically significant breach at L5 (III, medial) which resulted in a L5 radiculopathy. Kappa statistics showed excellent overall agreement between reviewers (k = 0.73–0.92; 90%–96% agreement). Conclusion. The two-dimensional (2D) virtual fluoroscopy is a clinically acceptable option for percutaneous placement of pedicle screws. However, this technique requires cautious application and is particularly vulnerable to axial trajectory errors.

[1]  Phillip M Young,et al.  Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. , 2009, Journal of neurosurgery. Spine.

[2]  S. Glaze,et al.  Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. , 2008, Journal of neurosurgery. Spine.

[3]  Tsung-Ting Tsai,et al.  Computer-assisted fluoroscopic navigation of pedicle screw insertion An in vivo feasibility study , 2004 .

[4]  Hua-Zi Xu,et al.  Image-guided pedicle screw insertion accuracy: a meta-analysis , 2009, International Orthopaedics.

[5]  Constantin Schizas,et al.  Pedicle Screw Placement Accuracy: A Meta-analysis , 2007, Spine.

[6]  D. Polly,et al.  Accuracy of Thoracic Pedicle Screws in Patients with and Without Coronal Plane Spinal Deformities , 2002, Spine.

[7]  Daniel J. Sucato Intraoperative Neurophysiologic Monitoring During Spinal Surgery , 2008 .

[8]  L. Nolte,et al.  Navigation an der Brust- und Lendenwirbelsäule mit dem 3D-Bildwandler , 2004, Der Chirurg.

[9]  K. Bulsara,et al.  Utility of Computerized Isocentric Fluoroscopy for Minimally Invasive Spinal Surgical Techniques , 2005, Journal of spinal disorders & techniques.

[10]  Y. R. Rampersaud,et al.  Clinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT Analysis , 2005, Spine.

[11]  R. Winter,et al.  Complications associated with pedicle screws. , 1999, The Journal of bone and joint surgery. American volume.

[12]  C. Petersilge,et al.  Accuracy of Using Computed Tomography to Identify Pedicle Screw Placement in Cadaveric Human Lumbar Spine , 1997, Spine.

[13]  Y. Rampersaud,et al.  Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw Insertion , 2000, Spine.

[14]  L. Nolte,et al.  [Intraoperative three-dimensional navigation for pedicle screw placement]. , 2004, Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen.

[15]  S. Gertzbein,et al.  Accuracy of Pedicular Screw Placement In Vivo , 1990, Spine.

[16]  Rick Sasso,et al.  Comparison of Radiation Exposure in Lumbar Pedicle Screw Placement With Fluoroscopy Vs Computer-Assisted Image Guidance With Intraoperative Three-Dimensional Imaging , 2008, The journal of spinal cord medicine.

[17]  C. Ohaegbulam Minimally Invasive Transmuscular Pedicle Screw Fixation of the Thoracic and Lumbar Spine , 2008 .

[18]  Ganesh Rao,et al.  Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. , 2002, Journal of neurosurgery.

[19]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[20]  A. Dhawan,et al.  In Vivo Accuracy of Thoracic Pedicle Screws , 2001, Spine.

[21]  M. Hardenbrook,et al.  Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot: Retrospective Study , 2010, Spine.

[22]  Jérôme Tonetti,et al.  Fluoroscopy-based navigation system in spine surgery , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  Musa Citak,et al.  Navigated pedicle screw placement: Experimental comparison between CT- and 3D fluoroscopy-based techniques , 2008, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[24]  Choll W. Kim,et al.  Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery. , 2008, The spine journal : official journal of the North American Spine Society.

[25]  W. Castro,et al.  Accuracy of Pedicle Screw Placement in Lumbar Vertebrae , 1996, Spine.

[26]  Christopher P Ames,et al.  Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature. , 2005, The spine journal : official journal of the North American Spine Society.

[27]  A. Sestokas,et al.  Neurophysiologic Monitoring of Spinal Nerve Root Function During Instrumented Posterior Lumbar Spine Surgery , 2002, Spine.