Detections of lunar exospheric ions by the LADEE neutral mass spectrometer

The Lunar Atmosphere and Dust Environment Explorer (LADEE) Neutral Mass Spectrometer (NMS), operating in ion mode, provides sensitive detections of ions from the lunar exosphere. By analyzing ion-mode data from the entire mission, utilizing Acceleration, Reconnection, Turbulence, and Electrodynamics of the Moon's Interaction with the Sun (ARTEMIS) plasma and magnetic field measurements to organize NMS data and eliminate background sources, we identify highly significant detections of lunar ions at mass per charge of 2, 4, 12, 20, 28, 39, and 40, moderately significant detections at 14 and 23, and weak detections at 24, 25, and 36. Unlike many previous observations of Moon-derived ions, an outward pointing viewing geometry ensures that these ions originate from the exosphere, rather than directly from the surface. For species with known neutral distributions, inferred ion production rates appear consistent with expectations for both magnitude and spatial distribution, assuming photoionization as the predominant source mechanism. Unexpected signals at mass per charge 12 and 28 suggest the presence of a significant exospheric population of carbon-bearing molecules.

[1]  Urs Mall,et al.  Influence of spacecraft outgassing on the exploration of tenuous atmospheres with in situ mass spectrometry , 2010 .

[2]  Werner Magnes,et al.  The THEMIS Fluxgate Magnetometer , 2008 .

[3]  Hisayoshi Shimizu,et al.  First in situ observation of the Moon‐originating ions in the Earth's Magnetosphere by MAP‐PACE on SELENE (KAGUYA) , 2009 .

[4]  P. Feldman,et al.  New upper limits on numerous atmospheric species in the native lunar atmosphere , 2013 .

[5]  S. Alan Stern,et al.  The lunar atmosphere: History, status, current problems, and context , 1999 .

[6]  S. Sasaki,et al.  In-flight Performance and Initial Results of Plasma Energy Angle and Composition Experiment (PACE) on SELENE (Kaguya) , 2010 .

[7]  David J. McComas,et al.  Lunar surface composition and solar wind‐Induced secondary ion mass spectrometry , 1991 .

[8]  R. Killen,et al.  Measuring pickup ions to characterize the surfaces and exospheres of planetary bodies: Applications to the Moon , 2006 .

[9]  S. Stern,et al.  A Spectroscopic Survey of Metallic Species Abundances in the Lunar Atmosphere , 1996 .

[10]  Paul D. Feldman,et al.  The Apollo 17 Ultraviolet Spectrometer: Lunar atmosphere measurements revisited , 1991 .

[11]  Hisayoshi Shimizu,et al.  First direct detection of ions originating from the Moon by MAP‐PACE IMA onboard SELENE (KAGUYA) , 2009 .

[12]  William M. Farrell,et al.  Lunar Pickup Ions Observed by ARTEMIS: Spatial and Temporal Distribution and Constraints on Species and Source Locations , 2012 .

[13]  G. Knoll Radiation detection and measurement , 1979 .

[14]  W. Huebner,et al.  Solar photo rates for planetary atmospheres and atmospheric pollutants , 1984 .

[15]  R. Abiad,et al.  The THEMIS ESA Plasma Instrument and In-flight Calibration , 2008 .

[16]  Urs Mall,et al.  Direct observation of lunar pick‐up ions near the Moon , 1998 .

[17]  Butler P. Hine,et al.  The Lunar Atmosphere and Dust Environment Explorer Mission , 2014 .

[18]  Vassilis Angelopoulos,et al.  The ARTEMIS Mission , 2011 .

[19]  J. Halekas,et al.  Using ARTEMIS pickup ion observations to place constraints on the lunar atmosphere , 2013 .

[20]  P. Mahaffy,et al.  Variability of helium, neon, and argon in the lunar exosphere as observed by the LADEE NMS instrument , 2015 .

[21]  V. Angelopoulos,et al.  ARTEMIS observations of lunar pick‐up ions in the terrestrial magnetotail lobes , 2012 .

[22]  J. Maurer,et al.  The Neutral Mass Spectrometer on the Lunar Atmosphere and Dust Environment Explorer Mission , 2014 .

[23]  Chunlai Li,et al.  Detection of m/q = 2 pickup ions in the plasma environment of the Moon: The trace of exospheric H2+ , 2011 .