PM25 measurements in ambient aerosol: comparison between Harvard impactor (HI) and the tapered element oscillating microbalance (TEOM) system.

A comparison, based on the regression of 32 daily mean PM25 aerosol loadings determined by a tapered element oscillating microbalance (TEOM) and by a Harvard impactor (HI), is reported for the ambient aerosol of Erfurt (Germany). The PM2.5 concentrations measured by the TEOM were systematically lower then those obtained by the HI. The ratio of the means TEOM/HI was 0.74 and the regression equation is TEOM = 0.69 x HI + 0.071. This result is consistent with reports elsewhere suggesting that semi-volatile aerosol material is lost from the heated sample filter on the TEOM. To verify this assertion, a heating system was developed for the HI which was able to keep the HI sample filter at 50+/-1 degrees C. After the implementation of this heating system, no systematically differences were observed between the TEOM and the heated HI system. The ratio of means was 1.06 and the regression equation TEOM = 1.10 x HI - 0.668. Because the measured levels of ammonium nitrate were very low in Erfurt, we concluded that other compounds like semi-volatile organics were responsible for the loss of particulate material at 50 degrees C.

[1]  Rebecca Bascom,et al.  Health effects of outdoor air pollution , 1996 .

[2]  A. Peters,et al.  Increased plasma viscosity during an air pollution episode: a link to mortality? , 1997, The Lancet.

[3]  F. Lurmann,et al.  Evaluation of the TEOM method for measurement of ambient particulate mass in urban areas. , 1997, Journal of the Air & Waste Management Association.

[4]  Field trials of the TEOM® and Partisol for PM10 monitoring in the St Austell china clay area, Cornwall, UK , 1999 .

[5]  D. Dockery,et al.  An association between air pollution and mortality in six U.S. cities. , 1993, The New England journal of medicine.

[6]  D. Dockery,et al.  Acute respiratory effects of particulate air pollution. , 1994, Annual review of public health.

[7]  J Schwartz,et al.  Air pollution and incidence of cardiac arrhythmia. , 2000, Epidemiology.

[8]  Joel Schwartz,et al.  REVIEW OF EPIDEMIOLOGICAL EVIDENCE OF HEALTH EFFECTS OF PARTICULATE AIR POLLUTION , 1995 .

[9]  John L. Gras,et al.  TEOM vs. manual gravimetric methods for determination of PM2.5 aerosol mass concentrations , 1999 .

[10]  Harvey Patashnick,et al.  Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance , 1990 .

[11]  John D. Spengler,et al.  Particles in our air : concentrations and health effects , 1996 .

[12]  S Perz,et al.  Increases in heart rate during an air pollution episode. , 1999, American journal of epidemiology.

[13]  A. Seaton,et al.  Comparison between a personal PM10 sampling head and the tapered element oscillating microbalance (TEOM) system , 1999 .

[14]  W G Kreyling,et al.  Daily mortality and fine and ultrafine particles in Erfurt, Germany part I: role of particle number and particle mass. , 2000, Research report.

[15]  Joachim Heinrich,et al.  Comparison of two particle-size spectrometers for ambient aerosol measurements , 2000 .