Influence of probe dynamic characteristics on the scanning speed for white light interference based AFM

Abstract The dynamic characteristics of an atomic force probe are important for rapid and accurate measurement in white light interference (WLI) based atomic force microscope (AFM). The tip of the probe will fly from the surface when its dynamic characteristics are poor, which will cause measurement error. Generally such tip flight can be avoided by reducing the scanning speed, which will decrease the error at the cost of measurement efficiency. In this paper, a dynamical model of atomic force probe is presented to analyze the causes of tip flight in the measurement process. A numerical simulation is performed on a typical sample surface to investigate the influence of profile, preloading and probe parameters on scanning speed. Experimental testing is conducted on a self-developed WLI based AFM, and the experimental results agree well with that of the theory. The maximum scanning speeds of the probe for a sample are tested under certain conditions. It is shown that for a certain probe, the tip flight occurs at the upwards points of the measured sample when the scanning speed exceeds the critical speed, which is constrained by the preloading.

[1]  M. Dahleh,et al.  Melnikov-Based Dynamical Analysis of Microcantilevers in Scanning Probe Microscopy , 1999 .

[2]  Jiunn-Jong Wu Simulation of rough surfaces with FFT , 2000 .

[3]  Xiaojun Liu,et al.  Non-linear dynamic compensation and re-sampling for tactile scanning measurement of curved surface topography based on GPS standards , 2012 .

[4]  David J. Whitehouse Dynamic aspects of scanning surface instruments and microscopes , 1990 .

[5]  Her-Terng Yau,et al.  Analysis of nonlinear dynamic behavior of atomic force microscope using differential transformation method , 2008 .

[6]  Jen-Ching Huang,et al.  Analysis of tip effects on the dynamic characteristics of V-shaped atomic force microscope probes , 2005, 2005 International Conference on MEMS,NANO and Smart Systems.

[7]  O. Loboda,et al.  Measurement of the probe impact force of the atomic force microscope operating in the amplitude modulation mode , 2014 .

[8]  M.N.H. Damir,et al.  Error in measurement due to stylus kinematics , 1973 .

[9]  Wenjun Yang,et al.  Towards a traceable probe calibration method for white light interference based AFM , 2018 .

[10]  Bijan Shirinzadeh,et al.  Vibration analysis of stylus instrument for random surface measurement , 2010, ICM 2009.

[11]  T. Vorburger,et al.  Characterization of Probe Dynamic Behaviors in Critical Dimension Atomic Force Microscopy , 2008, Journal of research of the National Institute of Standards and Technology.

[12]  Derek G. Chetwynd,et al.  Improvement of the fidelity of surface measurement by active damping control , 1993 .

[13]  Richard S Gates,et al.  Accurate and precise calibration of AFM cantilever spring constants using laser Doppler vibrometry , 2012, Nanotechnology.

[14]  Joseph A. Turner,et al.  Analysis of the high-frequency response of atomic force microscope cantilevers , 1997 .

[15]  D. Whitehouse Enhancement of instrument and machine capabilities , 1996 .

[16]  S. Okuma,et al.  A method for determining the spring constant of cantilevers for atomic force microscopy , 1996 .

[17]  Ute Rabe,et al.  Vibrations of free and surface‐coupled atomic force microscope cantilevers: Theory and experiment , 1996 .

[18]  Stephen Jesse,et al.  Band excitation in scanning probe microscopy: sines of change , 2011 .

[19]  Yanling Tian,et al.  Dynamic modelling of the fidelity of random surface measurement by the stylus method , 2009 .

[20]  J. Turner Non-linear vibrations of a beam with cantilever-Hertzian contact boundary conditions , 2004 .

[21]  A. Nayfeh,et al.  Contact force identification using the subharmonic resonance of a contact-mode atomic force microscopy , 2005, Nanotechnology.

[22]  Yanling Tian,et al.  Nonlinear viscoelastic modelling of stylus probing for surface metrology , 2013 .

[23]  J. Turner,et al.  Free vibrations of U-shaped atomic force microscope probes , 2014 .

[24]  Research on the Obtainment of Topography Parameters by Rough Surface Simulation With Fast Fourier Transform , 2015 .

[25]  Wenjun Yang,et al.  A Novel White Light Interference Based AFM Head , 2017, Journal of Lightwave Technology.

[26]  Suping Chang,et al.  A white light interference-based atomic force probe scanning microscopy , 2011 .