Design and Intra-operative Studies of an Economic Versatile Portable Biopotential Recorder

An economic, versatile, compact and portable biopotential amplifier [Electroneurograph] has been designed and implemented intra operatively. The most significant features of the instrument are variable cutoff for the low pass filter, variable gain, attenuation and optical isolation for the output. A fourth order low pass filter with bessel characteristic was designed using active filters. An attenuator is provided in between the gain stage and optical isolator such that the signals during supramaximal stimulations are attenuated. In this versatile bio-potential recorder, one of the outputs of the amplifier is isolated optically using IC MOC 3020 such that patient safely is ensured. The output portion of the instrumentation amplifier which is named head stage is designed separately and the inputs from the electrodes are given to the head stage by means of shielded coaxial cable. Also the whole bio-potential amplifier is properly shielded and grounded to minimize the noise effect. Offset control is provided for base line shift. The stimulating and recording electrodes were placed in appropriate positions and evoked responses were recorded. Conduction velocity was calculated by measuring the latency of waveform by stimulating at two different points along the nerve. Nerve conduction studies have been undertaken on leprosy patients who had undergone median and ulnar nerve corrective surgery and the result presented.

[1]  Ramon Pallàs-Areny,et al.  AC-coupled front-end for biopotential measurements , 2003, IEEE Transactions on Biomedical Engineering.

[2]  Sergio Franco,et al.  Design with Operational Amplifiers and Analog Integrated Circuits , 1988 .

[3]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[4]  George B. Rutkowski Operational Amplifiers: Integrated and Hybrid Circuits , 1993 .

[5]  Reid R. Harrison,et al.  A Versatile Integrated Circuit for the Acquisition of Biopotentials , 2007, 2007 IEEE Custom Integrated Circuits Conference.

[6]  J. Chopra,et al.  Phrenic nerve conduction in leprosy. , 1985, International journal of leprosy and other mycobacterial diseases.

[7]  J. Webster Encyclopedia of Medical Devices and Instrumentation , 1988 .

[8]  R. Mathai,et al.  A study of the conduction velocity of the motor fibers of ulnar and median nerves in leprosy. , 1970, International journal of leprosy and other mycobacterial diseases : official organ of the International Leprosy Association.

[9]  Leonardo Badillo,et al.  Low noise multichannel amplifier for portable EEG biomedical applications , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[10]  Vipin Seetohul,et al.  Some Recent Developments in the Design of Biopotential Amplifiers for ENG Recording Systems , 2006, APCCAS 2006 - 2006 IEEE Asia Pacific Conference on Circuits and Systems.

[11]  S. Husain,et al.  Early nerve damage in leprosy: an electrophysiological study of ulnar and median nerves in patients with and without clinical neural deficits. , 2007, Neurology India.