3D-printed coded apertures for x-ray backscatter radiography

Many different mask patterns can be used for X-ray backscatter imaging using coded apertures, which can find application in the medical, industrial and security sectors. While some of these patterns may be considered to have a self-supporting structure, this is not the case for some of the most frequently used patterns such as uniformly redundant arrays or any pattern with a high open fraction. This makes mask construction difficult and usually requires a compromise in its design by drilling holes or adopting a no two holes touching version of the original pattern. In this study, this compromise was avoided by 3D printing a support structure that was then filled with a radiopaque material to create the completed mask. The coded masks were manufactured using two different methods, hot cast and cold cast. Hot casting involved casting a bismuth alloy at 80°C into the 3D printed acrylonitrile butadiene styrene mould which produced an absorber with density of 8.6 g cm-3. Cold casting was undertaken at room temperature, when a tungsten/epoxy composite was cast into a 3D printed polylactic acid mould. The cold cast procedure offered a greater density of around 9.6 to 10 g cm-3 and consequently greater X-ray attenuation. It was also found to be much easier to manufacture and more cost effective. A critical review of the manufacturing procedure is presented along with some typical images. In both cases the 3D printing process allowed square apertures to be created avoiding their approximation by circular holes when conventional drilling is used.

[1]  R. Dicke SCATTER-HOLE CAMERAS FOR X-RAYS AND GAMMA RAYS. , 1968 .

[2]  Michael J. DeWeert,et al.  Lensless coded-aperture imaging with separable Doubly-Toeplitz masks , 2015 .

[3]  R. Accorsi,et al.  Optimal coded aperture patterns for improved SNR in nuclear medicine imaging , 2001 .

[4]  E. Caroli,et al.  Coded aperture imaging in X- and gamma-ray astronomy , 1987 .

[5]  B. E. Foster,et al.  X-RAY MASS ATTENUATION COEFFICIENTS IN THE RANGE OF 50 TO 150 KVP , 1963 .

[6]  J. P. Lewis Fast Normalized Cross-Correlation , 2010 .

[7]  Roberto Accorsi Design of a near-field coded aperture cameras for high-resolution medical and industrial gamma-ray imaging , 2001 .

[8]  Lawrence N Mertz,et al.  Fresnel transformation of images (Fresnel coding and decoding of images) , 1962 .

[9]  E. E. Fenimore,et al.  Uniformly redundant arrays: digital reconstruction methods. , 1981, Applied optics.

[10]  H. Barrett,et al.  3D printing in X-ray and Gamma-Ray Imaging: A novel method for fabricating high-density imaging apertures. , 2011, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[11]  E E Fenimore,et al.  New family of binary arrays for coded aperture imaging. , 1989, Applied optics.

[12]  T. M. Cannon,et al.  Coded aperture imaging with uniformly redundant arrays. , 1978, Applied optics.

[13]  Anthony A. Faust Detection of Explosive Devices using X-ray Backscatter Radiation , 2002, SPIE Optics + Photonics.