Bioreactors and Bioprocessing for Tissue Engineering

Abstract: Bioreactor design in tissue engineering is complex, and at the early stages of its development. Design of biologically effective, yet scalable, devices requires intimate collaboration between engineers and biologists to ensure that all aspects are considered fully. Growth conditions, harvesting time, scale‐up, storage, and sterility issues all need to be considered and incorporated into the design of bioreactors. Each tissue‐engineered product will likely require individualized bioreactor design. However, without a comprehensive understanding of each of these components, bioreactor design and tissue growth to manufacture product will remain at a relatively rudimentary and limited level. Increased fundamental understanding of the issues can have a dramatic impact on the ability to generate tissue‐engineered product safely, economically, and in the numbers that are required to fully address the patient populations in need.

[1]  J. Vacanti,et al.  Tissue engineering : Frontiers in biotechnology , 1993 .

[2]  N. Parenteau,et al.  Skin: the first tissue-engineered products. , 1999, Scientific American.

[3]  M. Kwan,et al.  Cartilage production by rabbit articular chondrocytes on polyglycolic acid scaffolds in a closed bioreactor system , 1995, Biotechnology and bioengineering.

[4]  R Langer,et al.  Functional arteries grown in vitro. , 1999, Science.

[5]  G A Ateshian,et al.  Functional tissue engineering of articular cartilage through dynamic loading of chondrocyte-seeded agarose gels. , 2000, Journal of biomechanical engineering.

[6]  R Langer,et al.  Morphologic and mechanical characteristics of engineered bovine arteries. , 2001, Journal of vascular surgery.

[7]  G. Naughton,et al.  The Advanced Tissue Sciences story. , 1999, Scientific American.

[8]  R. Ross The pathogenesis of atherosclerosis: a perspective for the 1990s , 1993, Nature.

[9]  U. Joos,et al.  Electrical stimulation influences mineral formation of osteoblast-like cells in vitro. , 2001, Biochimica et biophysica acta.

[10]  Robert L Sah,et al.  Perfusion increases cell content and matrix synthesis in chondrocyte three-dimensional cultures. , 2002, Tissue engineering.

[11]  H. Vandenburgh,et al.  Mechanical stimulation of organogenic cardiomyocyte growth in vitro. , 1996, The American journal of physiology.

[12]  Martin L. Yarmush,et al.  Tissue engineering methods and protocols , 1999 .

[13]  K J Gooch,et al.  IGF-I and mechanical environment interact to modulate engineered cartilage development. , 2001, Biochemical and biophysical research communications.

[14]  D. Katz,et al.  Physiological Patterns of Electrical Stimulation Can Induce Neuronal Gene Expression by Activating N-Type Calcium Channels , 2001, The Journal of Neuroscience.

[15]  L D Solem,et al.  A multicenter clinical trial of a biosynthetic skin replacement, Dermagraft-TC, compared with cryopreserved human cadaver skin for temporary coverage of excised burn wounds. , 1997, The Journal of burn care & rehabilitation.

[16]  M J Lysaght,et al.  The growth of tissue engineering. , 2001, Tissue engineering.

[17]  Ivan Martin,et al.  The FASEB Journal express article 10.1096/fj.01-0656fje. Published online December 28, 2001. Cell differentiation by mechanical stress , 2022 .