Comparison of sensititre dried microtitration trays with a standard agar method for determination of minimum inhibitory concentrations of antimicrobial agents

A total of 222 clinical isolates were used to test the accuracy of Sensititre dried microtitration trays for determining minimum inhibitory concentrations (MICs) of antimicrobial agents. In comparison with an agar dilution technique, 89.5% of all the pairs of results were within one doubling dilution. The 2,420 pairs of MIC results with finite values gave a corresponding figure of 86.8%. Exclusion of sulfisoxazole results, which demonstrated a significant interlaboratory variation in accuracy, raised this value to 89.1%. Very good differentiation of beta-lactamase-producing strains of Staphylococcus aureus (24 of 24 giving an MIC greater than or equal to 0.25 micrograms/ml) and Haemophilus influenzae (3 of 3 giving an MIC greater than or equal to 32 micrograms/ml) was obtained with the Sensititre system. This method also clearly distinguished erythromycin-resistant S. aureus strains (7 of 7 giving an MIC greater than 32 micrograms/ml) from the susceptible strains (26 of 28 giving an MIC less than or equal to 0.5 microgram/ml plus 1 strain at 1.0 microgram/ml and 1 at 2.0 micrograms/ml). Sensititre offers an accurate and convenient method of determining MICs comparable to those obtained with the agar dilution procedure, with the advantage of an extended shelf life when stored at room temperature.

[1]  R. Jones,et al.  Evaluation of the Sensititre system for quantitative antimicrobial drug susceptibility testing: a collaborative study , 1980, Antimicrobial Agents and Chemotherapy.

[2]  H. Koornhof,et al.  Antimicrobial Susceptibility Testing of Pneumococci: Determination of Kirby-Bauer Breakpoints for Penicillin G, Erythromycin, Clindamycin, Tetracycline, Chloramphenicol, and Rifampin , 1979, Antimicrobial Agents and Chemotherapy.

[3]  H. Neu,et al.  In Vitro Activity and β-Lactamase Stability of Cefazaflur Compared with Those of β-Lactamase-Stable Cephalosporins , 1979, Antimicrobial Agents and Chemotherapy.

[4]  E. A. Robertson,et al.  Evaluation of a Dispensing Instrument (Dynatech MIC-2000) for Preparing Microtiter Antibiotic Plates and Testing Their Potency During Storage , 1978, Antimicrobial Agents and Chemotherapy.

[5]  R. Jones,et al.  Evaluation of the Micro-Media System for Quantitative Antimicrobial Drug Susceptibility Testing: a Collaborative Study , 1978, Antimicrobial Agents and Chemotherapy.

[6]  J. Hamilton-miller Towards greater uniformity in sensitivity testing. , 1977, The Journal of antimicrobial chemotherapy.

[7]  P. Hoeprich,et al.  The antimicrobic susceptibility test : principles and practices , 1976 .

[8]  C. O'callaghan,et al.  Novel Method for Detection of β-Lactamases by Using a Chromogenic Cephalosporin Substrate , 1972, Antimicrobial Agents and Chemotherapy.

[9]  J. Sherris,et al.  Antibiotic sensitivity testing. Report of an international collaborative study. , 1971, Acta pathologica et microbiologica Scandinavica. Section B: Microbiology and immunology.

[10]  L. Garrod,et al.  Effect of medium composition on the apparent sensitivity of Pseudomonas aeruginosa to gentamicin , 1969, Journal of clinical pathology.