Spatial calibration of large volume photogrammetry based metrology systems

Photogrammetry systems are used extensively as volumetric measurement tools in a diverse range of applications including gait analysis, robotics and computer generated animation. For precision applications the spatial inaccuracies of these systems are of interest. In this paper, an experimental characterisation of a six camera Vicon T160 photogrammetry system using a high accuracy laser tracker is presented. The study was motivated by empirical observations of the accuracy of the photogrammetry system varying as a function of location within a measurement volume of approximately 100 m3. Error quantification was implemented through simultaneously tracking a target scanned through a sub-volume (27 m3) using both systems. The position of the target was measured at each point of a grid in four planes at different heights. In addition, the effect of the use of passive and active calibration artefacts upon system accuracy was investigated. A convex surface was obtained when considering error as a function of position for a fixed height setting confirming the empirical observations when using either calibration artefact. Average errors of 1.48 mm and 3.95 mm were obtained for the active and passive calibration artefacts respectively. However, it was found that through estimating and applying an unknown scale factor relating measurements, the overall accuracy could be improved with average errors reducing to 0.51 mm and 0.59 mm for the active and passive datasets respectively. The precision in the measurements was found to be less than 10 μm for each axis.

[1]  Gert-Peter Brüggemann,et al.  Evaluation of the performance of a motion capture system for small displacement recording and a discussion for its application potential in bone deformation in vivo measurements , 2012, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  Shinji Miyazaki,et al.  Comparison of the performance of 3D camera systems , 1995 .

[3]  Gordon Dobie,et al.  Visual odometry and image mosaicing for NDE , 2013 .

[4]  S. Umeyama,et al.  Least-Squares Estimation of Transformation Parameters Between Two Point Patterns , 1991, IEEE Trans. Pattern Anal. Mach. Intell..

[5]  Ieee Xplore,et al.  IEEE Transactions on Pattern Analysis and Machine Intelligence Information for Authors , 2022, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[6]  S. Evans,et al.  Accuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues. , 2007, Journal of biomechanics.

[7]  J. Richards,et al.  The measurement of human motion: A comparison of commercially available systems , 1999 .

[8]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. , 2004, Gait & posture.

[9]  Chris Bregler,et al.  Motion Capture Technology for Entertainment [In the Spotlight] , 2007, IEEE Signal Processing Magazine.

[10]  Marc Pollefeys,et al.  PIXHAWK: A micro aerial vehicle design for autonomous flight using onboard computer vision , 2012, Auton. Robots.

[11]  Hugh F. Durrant-Whyte,et al.  Simultaneous localization and mapping: part I , 2006, IEEE Robotics & Automation Magazine.

[12]  Aurelio Cappozzo,et al.  Gait analysis methodology , 1984 .

[13]  Markus Windolf,et al.  Systematic accuracy and precision analysis of video motion capturing systems--exemplified on the Vicon-460 system. , 2008, Journal of biomechanics.

[14]  P. Cerveri,et al.  A fast method for calibrating video-based motion analysers using only a rigid bar , 2006, Medical and Biological Engineering and Computing.

[15]  G. Hayward,et al.  A Noncontact Ultrasonic Platform for Structural Inspection , 2011, IEEE Sensors Journal.

[16]  Chris Bregler,et al.  Motion Capture Technology for Entertainment , 2007 .

[17]  Vijay Kumar,et al.  The GRASP Multiple Micro-UAV Testbed , 2010, IEEE Robotics & Automation Magazine.

[18]  S. Duke Herrell,et al.  Towards image guided robotic surgery: multi-arm tracking through hybrid localization , 2009, International Journal of Computer Assisted Radiology and Surgery.

[19]  K. S. Arun,et al.  Least-Squares Fitting of Two 3-D Point Sets , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.