Total Power Radiometer for Medical Sensor Applications Using Matched and Mismatched Noise Sources

This paper presents a simple total power radiometer to noninvasively measure the temperature of the human body. The proposed 3-GHz radiometer consists of an antenna collecting the noise power generated by a target, a low-noise and high-gain receiver amplifying the noise power, and a detector converting the noise power to voltage. A single-pole-triple-throw (SP3T) switch is placed between the antenna and the receiver, while a personal computer is used to control the SP3T switch, collect and process the data such as detector output voltages and physical temperatures of the reference noise sources and the target. The fabricated radiometer shows a good performance agreement with a thermometer in the temperature measurement of water from 25.0 to 43.1 °C. For the accurate prediction of the target temperature, the radiometer is calibrated adaptively to the environment and radiometer variations. For this purpose, two reference noise sources (hot and cold) are proposed using matched and mismatched resistors at room temperature. These resistor-based noise sources offer a reliable performance without complex temperature control systems. Furthermore, they can be easily calibrated in real time by periodically measuring the physical temperatures of the resistors. In addition, the logarithmic detector with wide dynamic range is adopted and logarithmically-fitted based on the measurement results instead of linear approximation, which reduces the error caused by the limited dynamic range of resistor-based noise sources. In order to further increase the accuracy, the performance imbalances between ports in the SP3T switch are also taken into account by employing offsets in the radiometer output voltages.

[1]  Chun-Sik Chae,et al.  Ka-band Total Power Radiometer and Temperature Control System for Calibration of Spatial Temperature Distribution , 2010, IEEE Sensors Journal.

[2]  Qingxia Li,et al.  A novel Dicke microwave radiometer without temperature control for reference match load , 2016, 2016 IEEE International Conference on Microwave and Millimeter Wave Technology (ICMMT).

[3]  Chun-Sik Chae,et al.  A Study of Compensation for Temporal and Spatial Physical Temperature Variation in Total Power Radiometers , 2012, IEEE Sensors Journal.

[4]  Martti Hallikainen,et al.  Development and Calibration of SMOS Reference Radiometer , 2007, IEEE Transactions on Geoscience and Remote Sensing.

[5]  Øystein Klemetsen,et al.  Improved Radiometric Performance Attained by an Elliptical Microwave Antenna With Suction , 2012, IEEE Transactions on Biomedical Engineering.

[6]  T. M. Weller,et al.  Towards Core Body Temperature Measurement via Close Proximity Radiometric Sensing , 2012, IEEE Sensors Journal.

[7]  Øystein Klemetsen,et al.  Improved Detectability in Medical Microwave Radio-Thermometers as Obtained by Active Antennas , 2008, IEEE Transactions on Biomedical Engineering.

[8]  Matti Kaisti,et al.  Uncertainty of Radiometer Calibration Loads and Its Impact on Radiometric Measurements , 2014, IEEE Transactions on Microwave Theory and Techniques.

[9]  Zoya Popovic,et al.  A 1.4 GHz MMIC Active Cold Noise Source , 2013, 2013 IEEE Compound Semiconductor Integrated Circuit Symposium (CSICS).

[10]  R. M. Arthur,et al.  Non-invasive estimation of hyperthermia temperatures with ultrasound , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  James B. Mead,et al.  Two-load radiometer precision and accuracy , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[12]  S. Ojica,et al.  Thermographic studies in vivo and in vitro for detection of tumor structures using microwave radiometry , 2013, 2013 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE).

[13]  W. Susek Thermal Microwave Radiation for Subsurface Absolute Temperature Measurement , 2010 .

[14]  Kamal Sarabandi,et al.  Microwave Radar and Radiometric Remote Sensing , 2013 .

[15]  Brian A. Maicke,et al.  Microwave system and methods for combined heating and radiometric sensing for blood perfusion measurement of tissue , 2016, 2016 IEEE MTT-S International Microwave Symposium (IMS).

[16]  S. Mizushina,et al.  Five‐band microwave radiometer system for noninvasive brain temperature measurement in newborn babies: Phantom experiment and confidence interval , 2011 .

[17]  Robert Scheeler A Microwave Radiometer for Internal Body Temperature Measurement , 2013 .

[18]  O Klemetsen,et al.  DESIGN OF MEDICAL RADIOMETER FRONT-END FOR IMPROVED PERFORMANCE. , 2011, Progress in electromagnetics research B. Pier B.

[19]  Zoya Popovic,et al.  Toward wearable wireless thermometers for internal body temperature measurements , 2014, IEEE Communications Magazine.

[20]  Robert Scheeler,et al.  A 1.4-GHz radiometer for internal body temperature measurements , 2015, 2015 European Microwave Conference (EuMC).

[21]  Øystein Klemetsen,et al.  Design and Evaluation of a Medical Microwave Radiometer for Observing Temperature Gradients Subcutaneously in the Human Body , 2012 .

[22]  Niels Skou,et al.  Performance measurements on active cold loads for radiometer calibration , 2007, 2007 IEEE International Geoscience and Remote Sensing Symposium.