A review of condition monitoring of underground power cables

Power distribution system relies heavily on a vast network of medium voltage (MV) underground cables for power delivery. Condition monitoring technologies can, therefore, play a vital role in attempting to target the cables that pose the most urgent reliability concerns. Maintaining or increasing a power system's reliability at minimal cost is an important issue for most network owners. Condition monitoring gives the information needed for safe and reliable operation, replacement strategy and hence increases the system reliability. Demands for reliable power causes a growing tendency to apply different strategies in the form of condition based maintenance. Partial discharge (PD) monitoring is one of the successful diagnostic tools for accessing the insulation condition of MV cables. Data acquired by online PD measurements can help in identifying the upcoming faults in such cable networks and possibly forecast the remaining life of the insulation. This paper reviews the condition monitoring and diagnostic techniques used for underground power cables.

[1]  Chien-Kuo Chang,et al.  The Use of Partial Discharges as an Online Monitoring System for Underground Cable Joints , 2011, IEEE Transactions on Power Delivery.

[2]  A. Cavallini,et al.  A new approach to partial discharge testing of HV cable systems , 2006, IEEE Electrical Insulation Magazine.

[3]  A. Cavallini,et al.  Localization of partial discharge sources along HV and MV cable routes , 2005, 2005 International Power Engineering Conference.

[4]  P.L. Lewin,et al.  Continuous on-line monitoring of partial discharges in high voltage cables , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.

[5]  J. Densley,et al.  Fundamentals of partial discharge in the context of field cable testing , 2000 .

[6]  K Khor,et al.  Partial discharge propagation and sensing in overhead power distribution lines , 2010 .

[7]  Roger Shuttleworth,et al.  On-line Partial Discharge (PD) Spot Testing and Monitoring of High Voltage Cable Sealing Ends , 2008 .

[8]  P.A.A.F. Wouters,et al.  Sensors for on-line PD detection in MV power cables and their locations in substations , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[9]  Mohammad Khalifa High-voltage engineering : theory and practice , 1990 .

[10]  E. Gulski,et al.  Advanced condition assessment of high voltage power cables , 2005, Proceedings of 2005 International Symposium on Electrical Insulating Materials, 2005. (ISEIM 2005)..

[11]  J. Densley An overview of aging mechanisms and diagnostics for extruded power cables , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[12]  J. Setyawan Investigation of Partial Discharge Occurrence and Detectability for High Voltage Power Cable Accessories , 2009 .

[13]  R. Bodega,et al.  On-site testing and PD diagnosis of high voltage power cables , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  Robert B. Northrop,et al.  Location and characterization of partial discharge sites in shielded power cables , 1990 .

[15]  P.L. Lewin,et al.  An improved optically based PD detection system for continuous on-line monitoring of HV cables , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  T.R. Blackburn,et al.  Practical experience in on-line partial discharge monitoring of power cables , 2008, 2008 Australasian Universities Power Engineering Conference.

[17]  P.C.J.M. van der Wielen,et al.  On-line PD monitoring system for MV cable connections with weak spot location , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[18]  E. Fontana,et al.  Real time monitoring of the leakage current of 230 kV insulator strings under washing , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition.