Intermittent Earth Fault Passage Indication in Compensated Distribution Networks

An intermittent or restriking earth fault is a special type of earth fault that is common mostly in compensated cable networks. A great deal of effort has gone into protection against this type of fault. However, locating this fault has not received much attention. Therefore, there is a need to have a reliable method for locating this fault to repair the damaged cable. In this paper, the principles of a new method developed for locating transient intermittent earth faults on distribution networks are presented. The proposed method employs negative and zero sequence currents, and no voltage measurement is required, which means the proposed method has the potential to reduce cost when implemented in practice. It is intended mainly for typical intermittent earth faults in cable distribution networks where the typical fault resistance is in the range of a few ohms. Real data obtained from practical field tests is used to explain the phenomenon. A series of disturbance recordings obtained from field tests validate the proposed method.

[1]  Nagy I. Elkalashy,et al.  Earth Fault Distance Estimation Using Active Traveling Waves in Energized-Compensated MV Networks , 2015, IEEE Transactions on Power Delivery.

[2]  Hadi Saadat,et al.  Power System Analysis , 1998 .

[3]  Ari Wahlroos,et al.  Novel algorithm for earth-fault location in compensated MV-networks , 2013 .

[4]  Kimmo Kauhaniemi,et al.  Earth Fault Location Using Negative Sequence Currents , 2019 .

[5]  Jiri Drapela,et al.  An earth fault location method based on negative sequence voltage changes at low voltage side of distribution transformers , 2020 .

[6]  Markku Hyvärinen,et al.  Helen Electricity Network Ltd.'s process towards high level of supply reliability , 2017 .

[8]  Janne Altonen,et al.  INTERMITTENT EARTH FAULTS-NEED TO IMPROVE THE EXISTING FEEDER EARTH FAULT PROTECTION SCHEMES? , 2003 .

[9]  J. Altonen,et al.  Application of novel cumulative phasor sum measurement for earth-fault protection in compensated MV-networks , 2013 .

[10]  Zhiqian Bo,et al.  Hilbert-Transform-Based Transient/Intermittent Earth Fault Detection in Noneffectively Grounded Distribution Systems , 2011, IEEE Transactions on Power Delivery.

[11]  Peter Schegner,et al.  Fast selective earth fault localization using the new fast pulse detection method , 2013 .

[12]  Seppo Hänninen,et al.  Single phase earth faults in high impedance grounded networks Characteristics, indication and location , 2001 .

[13]  Matti Lehtonen,et al.  Improving reliability in an urban network , 2015 .

[14]  Kimmo Kauhaniemi,et al.  Review of methodologies for earth fault indication and location in compensated and unearthed MV distribution networks , 2018 .

[15]  Ari Wahlroos,et al.  Application of Novel Multi-frequency Neutral Admittance Method into Earth-Fault Protection in Compensated MV-networks , 2014 .

[16]  Peter Schegner,et al.  Why does the earth-fault detection method based on third harmonic work in large meshed 110 kV networks , 2017 .

[17]  Gernot DRUML,et al.  DIRECTIONAL DETECTION OF RESTRIKING EARTHFAULTS IN COMPENSATED NETWORKS , 2011 .

[18]  Osmo Siirto,et al.  Improving reliability by focusing on the quality and condition of medium-voltage cables and cable accessories , 2017 .