Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.

Dosimetry audit plays an important role in the development and safety of radiotherapy. National and large scale audits are able to set, maintain and improve standards, as well as having the potential to identify issues which may cause harm to patients. They can support implementation of complex techniques and can facilitate awareness and understanding of any issues which may exist by benchmarking centres with similar equipment. This review examines the development of dosimetry audit in the UK over the past 30 years, including the involvement of the UK in international audits. A summary of audit results is given, with an overview of methodologies employed and lessons learnt. Recent and forthcoming more complex audits are considered, with a focus on future needs including the arrival of proton therapy in the UK and other advanced techniques such as four-dimensional radiotherapy delivery and verification, stereotactic radiotherapy and MR linear accelerators. The work of the main quality assurance and auditing bodies is discussed, including how they are working together to streamline audit and to ensure that all radiotherapy centres are involved. Undertaking regular external audit motivates centres to modernize and develop techniques and provides assurance, not only that radiotherapy is planned and delivered accurately but also that the patient dose delivered is as prescribed.

[1]  Graham Bass,et al.  A multi-institutional dosimetry audit of rotational intensity-modulated radiotherapy. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  M. Sydes,et al.  Implementing the UK Medical Research Council (MRC) RT01 trial (ISRCTN 47772397): methods and practicalities of a randomised controlled trial of conformal radiotherapy in men with localised prostate cancer. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  P. Hoskin,et al.  A survey of radiotherapy quality control practice in the United Kingdom for the START trial. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  B. Mcclean,et al.  A dosimetric intercomparison of brachytherapy facilities in Ireland, Scotland and the North of England. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  V. Grégoire,et al.  Outcome impact and cost-effectiveness of quality assurance for radiotherapy planned for the EORTC 22071-24071 prospective study for head and neck cancer. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  A. Dutreix,et al.  Preliminary results of a quality assurance network for radiotherapy centres in Europe , 1994 .

[7]  D. Thwaites,et al.  A dosimetric intercomparison of kilovoltage X-rays, megavoltage photons and electrons in the Republic of Ireland. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  H. Svensson,et al.  The IAEA/WHO TL dosimetry service for radiotherapy centres 1969-87. , 1990, Acta oncologica.

[9]  S. Dische,et al.  Quality assurance in the CHART clinical trial. , 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  V. Kouloulias Quality assurance in radiotherapy. , 2003, European journal of cancer.

[11]  D. Olsen,et al.  Quality assurance of dosimetry and the impact on sample size in randomized clinical trials. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  Yohsuke Kusano,et al.  Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  M. Bidmead,et al.  A survey of quality control practices for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy in the United Kingdom , 2012, Journal of contemporary brachytherapy.

[14]  A Bridier,et al.  The ESTRO-QUALity assurance network (EQUAL). , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  A national dosimetry audit of intraoperative radiotherapy. , 2013, The British journal of radiology.

[16]  H. Eisenlohr,et al.  IAEA-WHO cobalt-60 teletherapy dosimetry service using mailed LiF dosemeters. A survey of results obtaining during 1970-75. , 1977, Physics in medicine and biology.

[17]  Catharine H. Clark,et al.  A critical evaluation of the PTW 2D‐ARRAY seven29 and OCTAVIUS II phantom for IMRT and VMAT verification , 2013, Journal of applied clinical medical physics.

[18]  C. Clark,et al.  Development of a novel treatment planning test for credentialing rotational intensity-modulated radiotherapy techniques in the UK. , 2013, The British journal of radiology.

[19]  D. Dearnaley,et al.  Questionnaire based quality assurance for the RT01 trial of dose escalation in conformal radiotherapy for prostate cancer (ISRCTN 47772397). , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  L. Collette,et al.  Profile of European radiotherapy departments contributing to the EORTC Radiation Oncology Group (ROG) in the 21st century. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  W. Dries,et al.  Determination of the accuracy of implant reconstruction and dose delivery in brachytherapy in The Netherlands and Belgium. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  D Thwaites,et al.  Quality assurance in radiotherapy , 1995 .

[23]  S. Bhide,et al.  Dosimetry audit for a multi-centre IMRT head and neck trial. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  J. Horiot,et al.  The Quality Assurance programme of the Radiotherapy Group of the European Organization for Research and Treatment of Cancer (EORTC): a critical appraisal of 20 years of continuous efforts. , 2003, European journal of cancer.

[25]  R. Mackay,et al.  Radiotherapy physics research in the UK: challenges and proposed solutions. , 2012, British Journal of Radiology.

[26]  Tomas Kron,et al.  Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters. , 2014, Medical physics.

[27]  A Brahme,et al.  Dosimetric precision requirements in radiation therapy. , 1984, Acta radiologica. Oncology.

[28]  J. Venselaar,et al.  Intercomparison of calibration procedures for Ir-192 HDR sources in The Netherlands and Belgium. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[29]  Niels Bassler,et al.  Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  P. Williams,et al.  A national dosimetric audit of IMRT. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  A. Nahum,et al.  The IPEMB code of practice for electron dosimetry for radiotherapy beams of initial energy from 2 to 50 MeV based on an air kerma calibration. Institution of Physics and Engineering in Medicine and Biology. , 1996, Physics in medicine and biology.

[32]  D. Bradley,et al.  Dosimetric audit in brachytherapy. , 2014, The British journal of radiology.

[33]  N. Spyrou,et al.  Low-cost commercial glass beads as dosimeters in radiotherapy , 2014 .

[34]  A Nisbet,et al.  A dosimetric intercomparison of electron beams in UK radiotherapy centres. , 1997, Physics in medicine and biology.

[35]  Quan Chen,et al.  Objective assessment of deformable image registration in radiotherapy: a multi-institution study. , 2007, Medical physics.

[36]  C. Clark,et al.  A methodology for dosimetry audit of rotational radiotherapy using a commercial detector array. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[37]  David I. Thwaites,et al.  Accuracy required and achievable in radiotherapy dosimetry: have modern technology and techniques changed our views? , 2013 .

[38]  J. Venselaar,et al.  Development of a TLD mailed system for remote dosimetry audit for (192)Ir HDR and PDR sources. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[39]  C H Clark,et al.  Pre-trial quality assurance processes for an intensity-modulated radiation therapy (IMRT) trial: PARSPORT, a UK multicentre Phase III trial comparing conventional radiotherapy and parotid-sparing IMRT for locally advanced head and neck cancer. , 2009, The British journal of radiology.

[40]  Damien C Weber,et al.  QA makes a clinical trial stronger: evidence-based medicine in radiation therapy. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[41]  S C Lillicrap,et al.  Code of Practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration service , 1990 .

[42]  Asa Carlsson Tedgren,et al.  Audit on source strength determination for HDR and PDR (192)Ir brachytherapy in Sweden. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[43]  D I Thwaites,et al.  A dosimetric intercomparison of megavoltage photon beams in UK radiotherapy centres. , 1992, Physics in medicine and biology.

[44]  D. Followill,et al.  Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry. , 2012, Medical physics.

[45]  M. Williams,et al.  Improving patient safety in radiotherapy by learning from near misses, incidents and errors. , 2007, The British journal of radiology.

[46]  J. Galvin,et al.  Global harmonization of quality assurance naming conventions in radiation therapy clinical trials. , 2014, International journal of radiation oncology, biology, physics.

[47]  A multicentre 'end to end' dosimetry audit for cervix HDR brachytherapy treatment. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[48]  A Wambersie,et al.  What degree of accuracy is required and can be achieved in photon and neutron therapy? , 1987, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[49]  K. Johansson,et al.  Quality audit of radiotherapy with EORTC mailed in water TL-dosimetry. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[50]  C E de Almeida,et al.  Intercomparison of calibration procedures for 192Ir HDR sources in Brazil. , 1999, Physics in medicine and biology.

[51]  David S Followill,et al.  Challenges in credentialing institutions and participants in advanced technology multi-institutional clinical trials. , 2008, International journal of radiation oncology, biology, physics.

[52]  P. Hoskin,et al.  Three-dimensional distribution of radiation within the breast: an intercomparison of departments participating in the START trial of breast radiotherapy fractionation. , 2003, International journal of radiation oncology, biology, physics.

[53]  R J Gastorf,et al.  Mailable TLD system for photon and electron therapy beams. , 1986, International journal of radiation oncology, biology, physics.

[54]  Damien C Weber,et al.  Quality assurance for prospective EORTC radiation oncology trials: the challenges of advanced technology in a multicenter international setting. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[55]  Brian O'Sullivan,et al.  Critical impact of radiotherapy protocol compliance and quality in the treatment of advanced head and neck cancer: results from TROG 02.02. , 2010, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[56]  M R McEwen,et al.  The IPEM code of practice for electron dosimetry for radiotherapy beams of initial energy from 4 to 25 MeV based on an absorbed dose to water calibration. , 2003, Physics in medicine and biology.

[57]  Tomas Kron,et al.  Radiation therapy quality assurance in clinical trials--Global Harmonisation Group. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[58]  Pedro Andreo,et al.  The IAEA/WHO TLD postal dose quality audits for radiotherapy: a perspective of dosimetry practices at hospitals in developing countries. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[59]  D. Dearnaley,et al.  A versatile phantom for quality assurance in the UK Medical Research Council (MRC) RT01 trial (ISRCTN47772397) in conformal radiotherapy for prostate cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[60]  P Andreo,et al.  The IAEA/WHO TLD postal programme for radiotherapy hospitals. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[61]  Tomas Kron,et al.  A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom. , 2014, Medical physics.

[62]  A Nisbet,et al.  Polarity and ion recombination correction factors for ionization chambers employed in electron beam dosimetry. , 1998, Physics in medicine and biology.

[63]  A. Palmer,et al.  Analysis of regional radiotherapy dosimetry audit data and recommendations for future audits. , 2011, The British journal of radiology.

[64]  Claire Lemer,et al.  An international review of patient safety measures in radiotherapy practice. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[65]  J F Sutcliffe,et al.  A review of in vivo experimental methods to determine the composition of the human body. , 1996, Physics in medicine and biology.

[66]  A Dutreix,et al.  Quality control of radiotherapy centres in Europe: beam calibration. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[67]  P. Hoskin,et al.  The START trial-measurements in semi-anatomical breast and chest wall phantoms. , 2001, Physics in medicine and biology.

[68]  J. Bucci,et al.  Australasian brachytherapy audit: Results of the ‘end‐to‐end’ dosimetry pilot study , 2013, Journal of medical imaging and radiation oncology.

[69]  G. Ibbott,et al.  QA in Radiation Therapy: The RPC Perspective , 2010 .

[70]  Tomas Kron,et al.  Dosimetry for audit and clinical trials: challenges and requirements , 2013 .

[71]  P. Hoskin,et al.  The use of in vivo thermoluminescent dosimeters in the quality assurance programme for the START breast fractionation trial. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.