Evaluation of Hepatic Steatosis by Using Acoustic Structure Quantification US in a Rat Model: Comparison with Pathologic Examination and MR Spectroscopy.

Purpose To determine factors that significantly affect the focal disturbance (FD) ratio calculated with an acoustic structure quantification (ASQ) technique in a dietary-induced fatty liver disease rat model and to assess the diagnostic performance of the FD ratio in the assessment of hepatic steatosis by using histopathologic examination as a standard of reference. Materials and Methods Twenty-eight male F344 rats were fed a methionine-choline-deficient diet with a variable duration (3.5 days [half week] or 1, 2, 3, 4, 5, or 6 weeks; four rats in each group). A control group of four rats was maintained on a standard diet. At the end of each diet period, ASQ ultrasonography (US) and magnetic resonance (MR) spectroscopy were performed. Then, the rat was sacrificed and histopathologic examination of the liver was performed. Receiver operating characteristic curve analysis was performed to assess the diagnostic performance of the FD ratio in the evaluation of the degree of hepatic steatosis. The Spearman correlation coefficient was calculated to assess the correlation between the ordinal values, and multivariate linear regression analysis was used to identify significant determinant factors for the FD ratio. Results The diagnostic performance of the FD ratio in the assessment of the degree of hepatic steatosis (area under the receiver operating characteristic curve: 1.000 for 5%-33% steatosis, 0.981 for >33% to 66% steatosis, and 0.965 for >66% steatosis) was excellent and was comparable to that of MR spectroscopy. There was a strong negative linear correlation between the FD ratio and the estimated fat fraction at MR spectroscopy (Spearman ρ, -0.903; P < .001). Multivariate linear regression analysis showed that the degree of hepatic steatosis (P < .001) and fibrosis stage (P = .022) were significant factors affecting the FD ratio. Conclusion The FD ratio may potentially provide good diagnostic performance in the assessment of the degree of hepatic steatosis, with a strong negative linear correlation with the estimated fat fraction at MR spectroscopy. The degree of steatosis and stage of fibrosis at histopathologic examination were significant factors that affected the FD ratio. © RSNA, 2017 Online supplemental material is available for this article.

[1]  B. Choi,et al.  Hepatic steatosis in living liver donor candidates: preoperative assessment by using breath-hold triple-echo MR imaging and 1H MR spectroscopy. , 2014, Radiology.

[2]  R. Idilman,et al.  Hepatic steatosis: quantification by proton density fat fraction with MR imaging versus liver biopsy. , 2013, Radiology.

[3]  Jeong Min Lee,et al.  Quantification of hepatic macrosteatosis in living, related liver donors using T1‐independent, T2*‐corrected chemical shift MRI , 2012, Journal of magnetic resonance imaging : JMRI.

[4]  Y. Takikawa,et al.  Non-invasive determination of hepatic steatosis by acoustic structure quantification from ultrasound echo amplitude. , 2012, World journal of gastroenterology.

[5]  Meng-Su Zeng,et al.  Standardized Ultrasound Hepatic/Renal Ratio and Hepatic Attenuation Rate to Quantify Liver Fat Content: An Improvement Method , 2011, Obesity.

[6]  A. Nederveen,et al.  Noninvasive quantification of hepatic steatosis inrats using 3.0 T 1H‐magnetic resonance spectroscopy , 2010, Journal of magnetic resonance imaging : JMRI.

[7]  M. Salvatore,et al.  Sonographic hepatic-renal ratio as indicator of hepatic steatosis: comparison with (1)H magnetic resonance spectroscopy. , 2009, Metabolism: clinical and experimental.

[8]  Hiroyuki Hachiya,et al.  B-mode ultrasound with algorithm based on statistical analysis of signals: evaluation of liver fibrosis in patients with chronic hepatitis C. , 2009, AJR. American journal of roentgenology.

[9]  F. Schick,et al.  Non-invasive assessment and quantification of liver steatosis by ultrasound, computed tomography and magnetic resonance. , 2009, Journal of hepatology.

[10]  Xiaoping Hu,et al.  Measurement of hepatic lipid: high-speed T2-corrected multiecho acquisition at 1H MR spectroscopy--a rapid and accurate technique. , 2009, Radiology.

[11]  M. Knuiman,et al.  NAFLD as a Risk Factor for the Development of Diabetes and the Metabolic Syndrome: An Eleven-Year Follow-up Study , 2009, The American Journal of Gastroenterology.

[12]  T. V. van Gulik,et al.  Essential pathogenic and metabolic differences in steatosis induced by choline or methione‐choline deficient diets in a rat model , 2007, Journal of gastroenterology and hepatology.

[13]  P. Giral,et al.  Sampling variability of liver biopsy in nonalcoholic fatty liver disease. , 2005, Gastroenterology.

[14]  O. Cummings,et al.  Design and validation of a histological scoring system for nonalcoholic fatty liver disease , 2005, Hepatology.

[15]  B. Choi,et al.  Appropriateness of a donor liver with respect to macrosteatosis: application of artificial neural networks to US images--initial experience. , 2005, Radiology.

[16]  Jonathan C. Cohen,et al.  Prevalence of hepatic steatosis in an urban population in the United States: Impact of ethnicity , 2004, Hepatology.

[17]  G. Bedogni,et al.  The epidemiology of fatty liver , 2004, European journal of gastroenterology & hepatology.

[18]  P. Angulo,et al.  Nonalcoholic fatty liver disease. , 2002, Revista de gastroenterologia de Mexico.

[19]  Z. Younossi,et al.  Nonalcoholic fatty liver disease: a spectrum of clinical and pathological severity. , 1999, Gastroenterology.

[20]  H. Osawa,et al.  Sonographic diagnosis of fatty liver using a histogram technique that compares liver and renal cortical echo amplitudes , 1996, Journal of clinical ultrasound : JCU.

[21]  Jae Young Lee,et al.  Hepatic Steatosis: Assessment with Acoustic Structure Quantification of US Imaging. , 2016, Radiology.

[22]  J. Stoker,et al.  US cannot be used to predict the presence or severity of hepatic steatosis in severely obese adolescents. , 2012, Radiology.

[23]  Thomas M van Gulik,et al.  Hepatic lipid composition analysis using 3.0-T MR spectroscopy in a steatotic rat model. , 2012, Magnetic resonance imaging.