Novel Passive Implantable Atrial Defibrillator Using Transcutaneous Radiofrequency Energy Transmission Successfully Cardioverts Atrial Fibrillation

Background—Conventional methods for cardioversion of atrial fibrillation (AF) to sinus rhythm have numerous difficulties. A novel method for cardioversion using the passive implantable atrial defibrillator (PIAD) was tested in acute animal models. This device does not have a battery or a capacitor to store energy and is activated by transferring RF energy across the skin from an external transmitter to the subcutaneously implanted defibrillator. On activation, a novel monophasic shock waveform with 5% tilt is delivered to the heart via 2 intracardiac defibrillation leads. Methods and Results—Cardioversion attempts with the device were assessed in 2 phases: a feasibility and efficacy study and randomized comparison against standard waveforms. Defibrillation leads were placed transvenously into the distal coronary sinus and the right atrial appendage. These were connected to the subcutaneously implanted PIAD. Sustained AF was induced by rapid atrial pacing. The transmitter coil was placed on the skin overlying the defibrillator, and defibrillation synchronized to the R wave was attempted. The method was found to be efficacious at very low voltage and energy, with 100% cardioversion success observed for 10-ms 100-V shocks (mean energy, 1.54±0.02 J). The PIAD waveform had a higher cardioversion success rate than a truncated, 70% tilt monophasic exponential pulse (100 V, 100% versus 78.0±7.57%; P =0.001). There were no postshock complications. Conclusions—Considering these animal results, this method is promising for cardioverting AF in symptomatic patients.

[1]  A. Adgey,et al.  Factors determining success and energy requirements for cardioversion of atrial fibrillation: revised version. , 1991, The Quarterly journal of medicine.

[2]  D. Keane Impact of Pulse Characteristics on Atrial Defibrillation Energy Requirements , 1994, Pacing and clinical electrophysiology : PACE.

[3]  W. Irnich Optimal Truncation of Defibrillation Pulses , 1995, Pacing and clinical electrophysiology : PACE.

[4]  A J Camm,et al.  Atrioverter: an implantable device for the treatment of atrial fibrillation. , 1998, Circulation.

[5]  D. Fatkin,et al.  Transesophageal echocardiography before and during direct current cardioversion of atrial fibrillation: evidence for "atrial stunning" as a mechanism of thromboembolic complications. , 1994, Journal of the American College of Cardiology.

[6]  E. Daoud,et al.  Initial Clinical Experience With Ambulatory Use of an Implantable Atrial Defibrillator for Conversion of Atrial Fibrillation , 2000 .

[7]  H. Crijns,et al.  Prediction of uneventful cardioversion and maintenance of sinus rhythm from direct-current electrical cardioversion of chronic atrial fibrillation and flutter. , 1991, The American journal of cardiology.

[8]  Mani Soma,et al.  Radio-Frequency Coils in Implantable Devices: Misalignment Analysis and Design Procedure , 1987, IEEE Transactions on Biomedical Engineering.

[9]  C. Schmitt,et al.  Initial Experience with Intracardiac Atrial Defibrillation in Patients with Chronic Atrial Fibrillation , 1994, Pacing and clinical electrophysiology : PACE.

[10]  A. Camm,et al.  Efficacy and tolerability of transvenous low energy cardioversion of paroxysmal atrial fibrillation in humans. , 1995, Journal of the American College of Cardiology.

[11]  H. E. Stephenson,et al.  An inductively coupled RF system for the transmission of 1 kW of power through the skin. , 1971, IEEE transactions on bio-medical engineering.

[12]  P. Wolf,et al.  Conduction disturbances caused by high current density electric fields. , 1990, Circulation research.

[13]  K H Newby,et al.  Testing different biphasic waveforms and capacitances: effect on atrial defibrillation threshold and pain perception. , 1996, Journal of the American College of Cardiology.

[14]  H. Wellens,et al.  Use of sedation during cardioversion with the implantable atrial defibrillator. , 1999, Circulation.

[15]  J. B. Bridges,et al.  Death and damage caused by multiple direct current shocks: studies in an animal model. , 1988, European heart journal.

[16]  Kenneth A. Ellenbogen,et al.  Clinical Cardiac Pacing and Defibrillation , 2000 .

[17]  C.M. Zierhofer,et al.  High-efficiency coupling-insensitive transcutaneous power and data transmission via an inductive link , 1990, IEEE Transactions on Biomedical Engineering.

[18]  A. Adgey,et al.  Factors determining success and energy requirements for cardioversion of atrial fibrillation. , 1990, The Quarterly journal of medicine.

[19]  G. Ayers,et al.  Ventricular proarrhythmic effects of ventricular cycle length and shock strength in a sheep model of transvenous atrial defibrillation. , 1994, Circulation.

[20]  S. Lévy,et al.  Low-energy cardioversion of spontaneous atrial fibrillation. Immediate and long-term results. , 1997, Circulation.

[21]  J. Wharton,et al.  Internal atrial defibrillation in humans. Improved efficacy of biphasic waveforms and the importance of phase duration. , 1997, Circulation.

[22]  A. Adgey,et al.  Metabolic Changes and Mitochondrial Dysfunction Early Following Transthoracic Countershock in Dogs , 1989, Pacing and clinical electrophysiology : PACE.

[23]  S. Lévy,et al.  Multicenter low energy transvenous atrial defibrillation (XAD) trial results in different subsets of atrial fibrillation. , 1997, Journal of the American College of Cardiology.

[24]  G. Ayers,et al.  Rounded Biphasic Waveform Reduces Energy Requirements for Transvenous Catheter Cardioversion of Atrial Fibrillation and Flutter , 1997, Pacing and clinical electrophysiology : PACE.

[25]  K. Arakawa,et al.  Low energy synchronous transcatheter cardioversion of atrial flutter/fibrillation in the dog. , 1990, Journal of the American College of Cardiology.

[26]  R. Ideker,et al.  Internal Cardioversion of Atrial Fibrillation in Sheep , 1993, Circulation.

[27]  D. Krum,et al.  The Effect of Biphasic Waveform Tilt in Transvenous Atrial Defibrillation , 1997, Pacing and clinical electrophysiology : PACE.