Coupling of Fluid Field and Electrostatic Field for Electrical Capacitance Tomography

The performance of an electrical capacitance tomography (ECT) sensor is usually evaluated by static experiment with solid material(s) for some typical distributions encountered in two-phase flows. Considering the soft-field effect of an ECT sensor, the existing evaluation method is not appropriate for evaluating the performance of ECT for the real complex two-phase flows. In this paper, a new simulation model is proposed by coupling two physical fields: fluid field and electrostatic field, based on a mixture model and an electrostatic model. The mixture model is based on the diffusive flux model, which is suitable for liquid-solid mixtures with high concentration of solid particles. An ECT sensor with 12 electrodes is modeled based on an electrostatic model with a periodic excitation signal. The two models are coupled by an additional electric force in the momentum conservation equation in the mixture model. The time-varying permittivity distributions and capacitance data are obtained from the computational simulation based on the coupling model to investigate the performance of the ECT sensor and image reconstruction. Linear backprojection and Landweber iteration with different parameters are used to reconstruct images. Experiment was carried out using a rotation device with a 12-electrode ECT sensor to validate the simulation results. Both simulation and experimental results verify that the proposed coupling model is valid for evaluating the performance of ECT sensors and image reconstruction algorithms.

[1]  Haigang Wang,et al.  Image Reconstruction for Electrical Capacitance Tomography Based on Sparse Representation , 2015, IEEE Transactions on Instrumentation and Measurement.

[2]  W. Marsden I and J , 2012 .

[3]  J. R. Abbott,et al.  A constitutive equation for concentrated suspensions that accounts for shear‐induced particle migration , 1992 .

[4]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[5]  Zhang Bao-fen A Calculation Method of Sensitivity Distribution with Electrical Capacitance Tomography , 2006 .

[6]  Jiamin Ye,et al.  Measurement of particle concentration in a Wurster fluidized bed by electrical capacitance tomography sensors , 2014 .

[7]  Zhiyao Huang,et al.  Application of electrical capacitance tomography to the void fraction measurement of two-phase flow , 2001, IMTC 2001. Proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference. Rediscovering Measurement in the Age of Informatics (Cat. No.01CH 37188).

[8]  Yassir Makkawi,et al.  Integration of ECT measurements with hydrodynamic modelling of conventional gas-solid bubbling bed , 2007 .

[9]  Jiamin Ye,et al.  Investigation of flow hydrodynamics and regime transition in a gas-solids fluidized bed with different riser diameters , 2014 .

[10]  Andreas Acrivos,et al.  Viscous resuspension in fully developed laminar pipe flows , 1994 .

[11]  Wuqiang Yang,et al.  Role of tomography in gas/solids flow measurement , 2000 .

[12]  Jiamin Ye,et al.  Evaluation of Effect of Number of Electrodes in ECT Sensors on Image Quality , 2012, IEEE Sensors Journal.

[13]  Saba Mylvaganam,et al.  Comparison of Different Measurement Protocols in Electrical Capacitance Tomography Using Simulations , 2007, IEEE Transactions on Instrumentation and Measurement.

[14]  Haiqing Li,et al.  An Online Flow Pattern Identification System for Gas–Oil Two-Phase Flow Using Electrical Capacitance Tomography , 2006, IEEE Transactions on Instrumentation and Measurement.

[15]  Amy Cha-Tien Sun,et al.  A numerical and experimental study of batch sedimentation and viscous resuspension , 2002 .

[16]  Wuqiang Yang,et al.  Online measurement and control of solids moisture in fluidised bed dryers , 2009 .

[17]  Wuqiang Yang,et al.  An image-reconstruction algorithm based on Landweber's iteration method for electrical-capacitance tomography , 1999 .

[18]  Wuqiang Yang,et al.  Evaluation of Electrical Capacitance Tomography Sensors for Concentric Annulus , 2013, IEEE Sensors Journal.

[19]  Jiamin Ye,et al.  Characterization of Electrical Capacitance Tomography Sensors With Different Diameter , 2014, IEEE Sensors Journal.

[20]  Jiamin Ye,et al.  A sparsity reconstruction algorithm for electrical capacitance tomography based on modified Landweber iteration , 2014 .

[21]  Jiamin Ye,et al.  Concentric-annulus electrical capacitance tomography sensors , 2013 .

[22]  Wuqiang Yang,et al.  Design of electrical capacitance tomography sensors , 2010 .

[23]  Wuqiang Yang,et al.  New AC-based capacitance tomography system , 1999 .

[24]  M. R. Rząsa A new transducer of double processing for capacitive tomography , 2007 .

[25]  J. Peixinho,et al.  Free surface flow between two horizontal concentric cylinders , 2012, The European Physical Journal E.

[26]  Yi Li,et al.  Gas/oil/water flow measurement by electrical capacitance tomography , 2012, 2012 IEEE International Conference on Imaging Systems and Techniques Proceedings.

[27]  Huang Zhiyao,et al.  An online flow pattern identification system for gas-oil two-phase flow using electrical capacitance tomography , 2004, Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510).

[28]  C. J. Kotre,et al.  EIT image reconstruction using sensitivity weighted filtered backprojection. , 1994, Physiological measurement.