Subcutaneous implantable cardioverter defibrillator for dialysis patients: a strategy to reduce central vein stenoses and infections.

Central venous stenosis is a common complication of the transvenous leads associated with an implantable cardioverter defibrillator (ICD). Although epicardial leads have been reported to bypass this complication, their placement is much more invasive than the subcutaneous ICDs (SICDs) and requires the services of a cardiothoracic surgeon. Recent data have demonstrated successful defibrillation using an SICD. In this report, we present 4 long-term hemodialysis patients treated successfully with an SICD. 3 patients received the device for primary prevention of sudden cardiac death (cardiomyopathy with low ejection fraction). The patient in the fourth case had a prolonged QT interval and received the device for secondary prevention. 3 patients had an arteriovenous fistula, whereas 1 patient was dialyzing with a tunneled dialysis catheter. Insertion of an SICD is a minimally invasive procedure. By virtue of leaving the venous system untouched, this approach might offer the advantage of reduced risk of central venous stenosis and infection over an endocardial ICD with transvenous leads. SICD is not experimental; it has been approved by the US Food and Drug Administration and is currently being used in the United States and Europe.

[1]  L. Salman,et al.  Cardiovascular Implantable Electronic Device Leads in CKD and ESRD Patients: Review and Recommendations for Practice , 2013, Seminars in dialysis.

[2]  L. Salman,et al.  Transvenous Cardiac Implantable Electronic Devices and Hemodialysis Catheters: Recommendations to Curtail a Potentially Lethal Combination , 2012, Seminars in dialysis.

[3]  S. Carvalho,et al.  [Pacemaker lead-induced tricuspid stenosis: a report of two cases]. , 2012, Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology.

[4]  L. Salman,et al.  Epicardial Cardiac Rhythm Devices for Dialysis Patients: Minimizing the Risk of Infection and Preserving Central Veins , 2012, Seminars in dialysis.

[5]  W. Winkelmayer,et al.  Trends in the use and outcomes of implantable cardioverter-defibrillators in patients undergoing dialysis in the United States. , 2011, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[6]  David A. Drew,et al.  Transvenous cardiac device wires and vascular access in hemodialysis patients. , 2011, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[7]  L. Salman,et al.  Arteriovenous dialysis access-associated transvenous pacemaker infection. , 2011, Clinical nephrology.

[8]  B. Wilkoff,et al.  Transvenous Lead Extraction , 2011 .

[9]  L. Salman,et al.  Contamination of transvenous pacemaker leads due to tunneled hemodialysis catheter infection: a report of 2 cases. , 2010, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[10]  Walter R Wilson,et al.  Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association. , 2010, Circulation.

[11]  L. Salman,et al.  ASDIN: Patency Rates for Angioplasty in the Treatment of Pacemaker‐Induced Central Venous Stenosis in Hemodialysis Patients: Results of a Multi‐Center Study , 2009, Seminars in dialysis.

[12]  Maria Grazia Bongiorni,et al.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). , 2009, Heart rhythm.

[13]  Claudia Stöllberger,et al.  Guidelines for device-based therapy of cardiac rhythm abnormalities. , 2009, Heart rhythm.

[14]  J. Jukema,et al.  Risk factors and time delay associated with cardiac device infections: Leiden device registry , 2008, Heart.

[15]  Harlan M Krumholz,et al.  ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemaker , 2008, Circulation.

[16]  A. Greenspon,et al.  Lead‐Associated Endocarditis: The Important Role of Methicillin‐Resistant Staphylococcus aureus , 2008, Pacing and clinical electrophysiology : PACE.

[17]  Sunghuen Kim,et al.  A Report of Two Cases , 2008 .

[18]  David L Hayes,et al.  Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. , 2007, Journal of the American College of Cardiology.

[19]  S. Saba,et al.  Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003. , 2006, Journal of the American College of Cardiology.

[20]  D. Delurgio,et al.  Renal Insufficiency and the Risk of Infection from Pacemaker or Defibrillator Surgery , 2006, Pacing and clinical electrophysiology : PACE.

[21]  T. Sundt,et al.  Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads. , 2005, Journal of the American College of Cardiology.

[22]  Douglas L Packer,et al.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. , 2005, The New England journal of medicine.

[23]  Akshay S. Desai,et al.  Implantable Defibrillators for the Prevention of Mortality in Patients With Nonischemic Cardiomyopathy: A Meta-analysis of Randomized Controlled Trials , 2004 .

[24]  P. Heidenreich,et al.  Increasing rates of cardiac device infections among Medicare beneficiaries: 1990-1999. , 2004, American heart journal.

[25]  L. Wong,et al.  Symptomatic Subclavian Vein Stenosis and Occlusion in Hemodialysis Patients with Transvenous Pacemakers , 2003, Annals of vascular surgery.

[26]  M. M. Filho,et al.  Incidence and Risk Factors of Upper Extremity Deep Vein Lesions After Permanent Transvenous Pacemaker Implant: A 6‐Month Follow‐Up Prospective Study , 2002, Pacing and clinical electrophysiology : PACE.

[27]  J. Oss,et al.  PROPHYLACTIC IMPLANTATION OF A DEFIBRILLATOR IN PATIENTS WITH MYOCARDIAL INFARCTION AND REDUCED EJECTION FRACTION , 2002 .

[28]  Vance G. Fowler,et al.  Staphylococcus aureus Bacteremia in Patients With Permanent Pacemakers or Implantable Cardioverter-Defibrillators , 2001, Circulation.

[29]  K. Wasmer,et al.  Prevalence of central venous occlusion in patients with chronic defibrillator leads. , 2001, American heart journal.

[30]  M. Henein,et al.  Pacemaker lead related tricuspid stenosis: a report of two cases , 2000, Heart.

[31]  M. Keller,et al.  A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. , 1997, The New England journal of medicine.