An integrated ultrasound transducer driver for HIFU applications

This paper presents for the first time an MRI-compatible integrated CMOS amplifier capable of directly driving a piezoelectric ultrasound transducer for High Intensity Focused Ultrasound (HIFU) applications. The amplifier operates in class DE mode loaded with a piezoelectric ultrasound transducer connected in parallel with a shunt capacitor. There is no need for external inductors. The integrated amplifier is implemented with the Teledyne-DALSA 0.8 μm CMOS process. Modeling of the piezoelectric transducer and amplifier design considerations are presented, followed by simulation results obtained using the Spectre simulator. The proposed design achieves over 80% efficiency with 1 W of output power at 1 MHz and an acceptable third harmonic level. The estimated die area of the amplifier is 2 mm2.

[1]  Bo Zhang,et al.  Class D Power Amplifier for Audio Beam System , 2007, 2007 International Conference on Mechatronics and Automation.

[2]  T. Suzuki,et al.  Automatic frequency control for maximizing RF power fed to ultrasonic transducer operating at 1 MHz , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[3]  Hung Liang Cheng,et al.  Single-switch high power factor inverter for driving piezoelectric ceramic transducer , 2009, 2009 International Conference on Power Electronics and Drive Systems (PEDS).

[4]  Hiroo Sekiya,et al.  Operation of class DE amplifier outside optimum condition , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[5]  George K Lewis,et al.  Design and characterization of a high-power ultrasound driver with ultralow-output impedance. , 2009, The Review of scientific instruments.

[6]  K. Agbossou,et al.  Class D amplifier for a power piezoelectric load , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Hussein Ballan,et al.  High-Voltage Analog and Digital Output Interfaces , 1999 .

[8]  Hussein Ballan,et al.  High Voltage Devices and Circuits in Standard CMOS Technologies , 1998 .

[9]  Linas Svilainis,et al.  Optimization of the ultrasonic excitation stage , 2008, ITI 2008 - 30th International Conference on Information Technology Interfaces.

[10]  C. Stoner Transmission-Line Theory , 1957, Nature.

[11]  G. ter Haar,et al.  Ultrasound focal beam surgery. , 1995, Ultrasound in medicine & biology.

[12]  Woon Tiong Ang,et al.  Design and Implementation of Therapeutic Ultrasound Generating Circuit for Dental Tissue Formation and Tooth-Root Healing , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[13]  Timothy L. Hall,et al.  A Low Cost Compact 512 Channel Therapeutic Ultrasound System For Transcutaneous Ultrasound Surgery , 2006 .

[14]  R. Riener,et al.  Review on MR-Compatible Robotic Systems , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[15]  Sydney C.W. Tang,et al.  Errata for "A harmonic cancellation technique for an ultrasound transducer excited by a switched-mode power converter" [Feb 08 359-367] , 2008 .

[16]  Sai Chun Tang,et al.  A harmonic cancellation technique for an ultrasound transducer excited by a switched-mode power converter , 2008, 2008 IEEE Ultrasonics Symposium.

[17]  Tadashi Suetsugu,et al.  Class DE high-efficiency tuned power amplifier , 1996 .

[18]  M. Albulet An exact analysis of Class-DE amplifier at any output Q , 1999 .