Measurements of temperature increase induced on a tissue-mimicking material by a clinical US-guided HIFU system

A framework for the evaluation of temperature increase in a tissue-mimicking material (TMM) induced by a clinical Ultrasound-guided High Intensity Focused Ultrasound (US-guided HIFU) system was developed. HIFU procedures are minimally invasive treatments that achieve deep tumor ablation, with the sparing of normal tissues, through thermal or mechanical effects induced by a HIFU beam generated with a focused transducer. Temperature evaluation is therefore crucial for the assurance of patient safety and treatment effectiveness. Nevertheless, it is a very difficult task on the US-guided systems, where high-pressure fields are involved. As far as we know, this study is the first attempt of temperature evaluation on a clinical US-guided HIFU system. Temperature evaluation was performed at typical clinical settings (between 80 W and 400 W, for 3s sonications) by the use of needle thermocouples connected to a voltmeter and inserted in a polyacrylamide gel phantom, prepared in-house to reproduce soft tissue behavior. Data sampling was performed with the use of acquisition software developed with LabView, while US-imaging was used to verify the position of the thermocouple. Typical rising curves of temperature were recovered, and rapid decrease was found when the HIFU field turned off. The highest temperature increases were concentrated inside the geometrical focus and were higher than 55 Celsius degrees at all power outputs. Repetition of measurements was not possible after sonications at the highest power outputs (400W). The absolute temperature of 98 Celsius degrees was never exceeded.

[1]  F A Jolesz,et al.  Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging. , 1999, Medical physics.

[2]  I. Rivens,et al.  Treatment monitoring and thermometry for therapeutic focused ultrasound , 2007, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[3]  R. Dickinson Thermal conduction errors of manganin-constantan thermocouple arrays , 1985 .

[4]  Shahram Vaezy,et al.  Polyacrylamide gel as an acoustic coupling medium for focused ultrasound therapy. , 2003, Ultrasound in medicine & biology.

[5]  Ian Rivens,et al.  Investigation of the viscous heating artefact arising from the use of thermocouples in a focused ultrasound field , 2008, Physics in medicine and biology.

[6]  W. Walker,et al.  Development and characterization of a vitreous mimicking material for radiation force imaging , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Lawrence A Crum,et al.  Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound. , 2010, Ultrasound in medicine & biology.

[8]  Faqi Li,et al.  Acoustic power measurement of high intensity focused ultrasound in medicine based on radiation force. , 2006, Ultrasonics.

[9]  Gavriel Speyer,et al.  Displacement analysis of diagnostic ultrasound backscatter: a methodology for characterizing, modeling, and monitoring high intensity focused ultrasound therapy. , 2010, The Journal of the Acoustical Society of America.

[10]  J. Alison Noble,et al.  Model-based ultrasound temperature visualization during and following HIFU exposure. , 2010, Ultrasound in medicine & biology.

[11]  P. Meaney,et al.  The intensity dependence of lesion position shift during focused ultrasound surgery. , 2000, Ultrasound in medicine & biology.

[12]  P. Hariharan,et al.  Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels. , 2011, Ultrasonics.

[13]  M. Fink,et al.  Temperature estimation using ultrasonic spatial compound imaging , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.