Knowledge-based IMRT treatment planning for prostate cancer

PURPOSE To demonstrate the feasibility of using a knowledge base of prior treatment plans to generate new prostate intensity modulated radiation therapy (IMRT) plans. Each new case would be matched against others in the knowledge base. Once the best match is identified, that clinically approved plan is used to generate the new plan. METHODS A database of 100 prostate IMRT treatment plans was assembled into an information-theoretic system. An algorithm based on mutual information was implemented to identify similar patient cases by matching 2D beam's eye view projections of contours. Ten randomly selected query cases were each matched with the most similar case from the database of prior clinically approved plans. Treatment parameters from the matched case were used to develop new treatment plans. A comparison of the differences in the dose-volume histograms between the new and the original treatment plans were analyzed. RESULTS On average, the new knowledge-based plan is capable of achieving very comparable planning target volume coverage as the original plan, to within 2% as evaluated for D98, D95, and D1. Similarly, the dose to the rectum and dose to the bladder are also comparable to the original plan. For the rectum, the mean and standard deviation of the dose percentage differences for D20, D30, and D50 are 1.8% +/- 8.5%, -2.5% +/- 13.9%, and -13.9% +/- 23.6%, respectively. For the bladder, the mean and standard deviation of the dose percentage differences for D20, D30, and D50 are -5.9% +/- 10.8%, -12.2% +/- 14.6%, and -24.9% +/- 21.2%, respectively. A negative percentage difference indicates that the new plan has greater dose sparing as compared to the original plan. CONCLUSIONS The authors demonstrate a knowledge-based approach of using prior clinically approved treatment plans to generate clinically acceptable treatment plans of high quality. This semiautomated approach has the potential to improve the efficiency of the treatment planning process while ensuring that high quality plans are developed.

[1]  Niko Papanikolaou,et al.  Dosimetric Impacts of Gantry Angle Misalignment on Prostate Cancer Treatment using Helical Tomotherapy , 2008, Technology in cancer research & treatment.

[2]  D L Hill,et al.  Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. , 1997, Medical physics.

[3]  Radhe Mohan,et al.  Algorithm and performance of a clinical IMRT beam-angle optimization system. , 2003, Physics in medicine and biology.

[4]  S. Webb Optimisation of conformal radiotherapy dose distributions by simulated annealing. , 1989, Physics in medicine and biology.

[5]  P. Koper,et al.  Acute and late complications after radiotherapy for prostate cancer: results of a multicenter randomized trial comparing 68 Gy to 78 Gy. , 2005, International journal of radiation oncology, biology, physics.

[6]  A Brahme,et al.  Optimization of radiation therapy and the development of multi-leaf collimation. , 1993, International journal of radiation oncology, biology, physics.

[7]  U Mahantshetty,et al.  Does Helical Tomotherapy Improve Dose Conformity and Normal Tissue Sparing Compared to Conventional IMRT? A Dosimetric Comparison in High Risk Prostate Cancer , 2011, Technology in cancer research & treatment.

[8]  D. Dearnaley,et al.  Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trial , 1999, The Lancet.

[9]  H. Sze,et al.  RapidArc radiotherapy planning for prostate cancer: single-arc and double-arc techniques vs. intensity-modulated radiotherapy. , 2012, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[10]  S Webb,et al.  Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator. II: constraints and limitations on 2D modulation. , 1998, Physics in medicine and biology.

[11]  Brent J. Liu,et al.  A Knowledge-Based Imaging Informatics Approach for Managing Proton Beam Therapy of Cancer Patients , 2007, Technology in cancer research & treatment.

[12]  T. Kairn,et al.  EBT2 radiochromic film for quality assurance of complex IMRT treatments of the prostate: micro-collimated IMRT, RapidArc, and TomoTherapy , 2011, Australasian Physical & Engineering Sciences in Medicine.

[13]  Kuan J Lee,et al.  Automated gamma knife radiosurgery treatment planning with image registration, data-mining, and Nelder-Mead simplex optimization. , 2006, Medical physics.

[14]  Joshua D. Lawson,et al.  Evaluation of automatic atlas-based lymph node segmentation for head-and-neck cancer. , 2010, International journal of radiation oncology, biology, physics.

[15]  Josien P. W. Pluim,et al.  Evaluation of Optimization Methods for Nonrigid Medical Image Registration Using Mutual Information and B-Splines , 2007, IEEE Transactions on Image Processing.

[16]  C. Floyd,et al.  Evaluation of information-theoretic similarity measures for content-based retrieval and detection of masses in mammograms. , 2006, Medical physics.

[17]  E Sterpin,et al.  Monte carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator. , 2007, Medical physics.

[18]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.

[19]  B. Bjärngard Optimization in radiation therapy. , 1977, International journal of radiation oncology, biology, physics.

[20]  Riccardo Calandrino,et al.  Anatomical and clinical predictors of acute bowel toxicity in whole pelvis irradiation for prostate cancer with Tomotherapy. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  T Kron,et al.  Optimization of helical tomotherapy treatment plans for prostate cancer. , 2003, Physics in medicine and biology.

[22]  E. Heath,et al.  Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV. , 2004, Medical physics.

[23]  Richard K Valicenti,et al.  Toxicity after three-dimensional radiotherapy for prostate cancer with RTOG 9406 dose level IV. , 2004, International journal of radiation oncology, biology, physics.

[24]  Myonggeun Yoon,et al.  A new homogeneity index based on statistical analysis of the dose–volume histogram , 2007, Journal of applied clinical medical physics.

[25]  Eva Bezak,et al.  Assessment of normal tissue complications following prostate cancer irradiation: comparison of radiation treatment modalities using NTCP models. , 2010, Medical physics.

[26]  M K Markey,et al.  Application of the mutual information criterion for feature selection in computer-aided diagnosis. , 2001, Medical physics.

[27]  Juergen Meyer,et al.  A RapidArc planning strategy for prostate with simultaneous integrated boost , 2010, Journal of applied clinical medical physics.

[28]  Stefan Klein,et al.  Cerebellum segmentation in MRI using atlas registration and local multi-scale image descriptors , 2009, 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[29]  R Mohan,et al.  Clinically relevant optimization of 3-D conformal treatments. , 1992, Medical physics.

[30]  Issam El-Naqa,et al.  RTOG GU Radiation oncology specialists reach consensus on pelvic lymph node volumes for high-risk prostate cancer. , 2009, International journal of radiation oncology, biology, physics.

[31]  R Mohan,et al.  Dose-volume histograms. , 1991, International journal of radiation oncology, biology, physics.

[32]  W. R. Lee,et al.  Knowledge-based IMRT treatment planning for prostate cancer. , 2011 .

[33]  S Cora,et al.  Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code. , 2003, Medical physics.

[34]  Margie Hunt,et al.  Intensity-modulated radiation therapy: supportive data for prostate cancer. , 2008, Seminars in radiation oncology.

[35]  W. Curran,et al.  Common toxicity criteria: version 2.0. an improved reference for grading the acute effects of cancer treatment: impact on radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[36]  Jan J W Lagendijk,et al.  Comparing step-and-shoot IMRT with dynamic helical tomotherapy IMRT plans for head-and-neck cancer. , 2005, International journal of radiation oncology, biology, physics.

[37]  T L Phillips,et al.  Toxicity following high-dose three-dimensional conformal and intensity-modulated radiation therapy for clinically localized prostate cancer. , 2001, Urology.

[38]  Max A. Viergever,et al.  elastix: A Toolbox for Intensity-Based Medical Image Registration , 2010, IEEE Transactions on Medical Imaging.

[39]  Wentian Li Mutual information functions versus correlation functions , 1990 .

[40]  W Schlegel,et al.  Physical vs. biological objectives for treatment plan optimization. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[41]  Gary Luxton,et al.  Dosimetry and radiobiologic model comparison of IMRT and 3D conformal radiotherapy in treatment of carcinoma of the prostate. , 2004, International journal of radiation oncology, biology, physics.

[42]  Xiao Han,et al.  Atlas-Based Auto-segmentation of Head and Neck CT Images , 2008, MICCAI.

[43]  C Clifton Ling,et al.  High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients. , 2002, International journal of radiation oncology, biology, physics.

[44]  T E Schultheiss,et al.  Factors influencing incidence of acute grade 2 morbidity in conformal and standard radiation treatment of prostate cancer. , 1995, International journal of radiation oncology, biology, physics.

[45]  Peter Kneschaurek,et al.  A Planning Comparison of Dynamic IMRT for Different Collimator Leaf Thicknesses with Helical Tomotherapy and RapidArc for Prostate and Head and Neck Tumors , 2010, Strahlentherapie und Onkologie.

[46]  Joseph O Deasy,et al.  The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. , 2010, International journal of radiation oncology, biology, physics.

[47]  Joos V Lebesque,et al.  Comparison between manual and automatic segment generation in step-and-shoot IMRT of prostate cancer. , 2003, Medical physics.

[48]  T. Bortfeld,et al.  Optimization of beam orientations in radiation therapy: some theoretical considerations. , 1993, Physics in medicine and biology.

[49]  S. Webb The physical basis of IMRT and inverse planning. , 2003, The British journal of radiology.

[50]  P. Maddock Intensity modulated radiation therapy. , 2006, Medicine and health, Rhode Island.

[51]  L. Constine,et al.  Normal tissue tolerance dose metrics for radiation therapy of major organs. , 2007, Seminars in radiation oncology.

[52]  Thomas M. Cover,et al.  Elements of Information Theory , 2005 .

[53]  S L Hancock,et al.  Role of beam orientation optimization in intensity-modulated radiation therapy. , 2001, International journal of radiation oncology, biology, physics.

[54]  R Mohan,et al.  Intensity modulation optimization, lateral transport of radiation, and margins. , 1996, Medical physics.

[55]  Fang-Fang Yin,et al.  SU‐FF‐T‐208: Efficient Selection of Beam Number and Orientations for Intensity Modulated Radiotherapy (IMRT) by Emulating An Ideal Dose Distribution , 2006 .

[56]  Steve Webb,et al.  Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[57]  Elisabetta Cagni,et al.  Dose-volume and biological-model based comparison between helical tomotherapy and (inverse-planned) IMAT for prostate tumours. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[58]  R. Cowan,et al.  Scoring of treatment-related late effects in prostate cancer. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[59]  F. Lohr,et al.  Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[60]  Swatee Singh,et al.  Information-theoretic CAD system in mammography: entropy-based indexing for computational efficiency and robust performance. , 2007, Medical physics.

[61]  Markus Neuhäuser,et al.  Wilcoxon Signed Rank Test , 2006 .

[62]  Russell H. Taylor,et al.  Data-driven approach to generating achievable dose-volume histogram objectives in intensity-modulated radiotherapy planning. , 2011, International journal of radiation oncology, biology, physics.

[63]  A Brahme,et al.  Development of Radiation Therapy Optimization , 2000, Acta oncologica.

[64]  A L Boyer,et al.  An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators , 1998, Physics in medicine and biology.

[65]  Soulimane Abdellaoui,et al.  Atlas-based semiautomatic target volume definition (CTV) for head-and-neck tumors. , 2010, International journal of radiation oncology, biology, physics.

[66]  Fang-Fang Yin,et al.  Radiotherapy treatment plans with RapidArc for prostate cancer involving seminal vesicles and lymph nodes. , 2010, International journal of radiation oncology, biology, physics.

[67]  Luca Cozzi,et al.  IMRT with the sliding window: comparison of the static and dynamic methods. Dosimetric and spectral analysis. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[68]  Norbert Ailleres,et al.  Persistently better treatment planning results of intensity-modulated (IMRT) over conformal radiotherapy (3D-CRT) in prostate cancer patients with significant variation of clinical target volume and/or organs-at-risk. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[69]  Russell H. Taylor,et al.  Patient geometry-driven information retrieval for IMRT treatment plan quality control. , 2009, Medical physics.

[70]  Joseph O Deasy,et al.  CERR: a computational environment for radiotherapy research. , 2003, Medical physics.

[71]  Stefan Klein,et al.  Automatic segmentation of the prostate in 3D MR images by atlas matching using localized mutual information. , 2008, Medical physics.

[72]  Max A. Viergever,et al.  Registration of Cervical MRI Using Multifeature Mutual Information , 2009, IEEE Transactions on Medical Imaging.

[73]  S. Webb Optimizing the planning of intensity-modulated radiotherapy. , 1994, Physics in medicine and biology.