An innovative test method for evaluating the critical moisture level for mould growth on building materials

Abstract The critical moisture level (RH crit ) for mould growth, that is the lowest relative humidity (RH) at which mould can grow, varies between different materials. The factors that most affect mould growth, RH and temperature, also vary in different parts of a building. One way of preventing the growth of mould in buildings is therefore to choose building materials that can withstand the expected conditions, materials that have a higher critical moisture level than the highest expected RH. It is thus crucial that data are available to allow the correct choice of materials to be made. In this paper an innovative laboratory test method for determining the RH crit of a material is described and discussed. The results from testing of a material according to the method gives information to make the correct choices. The method is developed based on the results of a variety of laboratory studies and has been validated by field studies.

[1]  Ocg Olaf Adan,et al.  On the fungal defacement of interior finishes , 1994 .

[2]  K. Nielsen,et al.  Mould growth on building materials under low water activities: Influence of humidity and temperature on fungal growth and secondary metabolism , 2004 .

[3]  Anne Hyvärinen,et al.  Fungi and actinobacteria in moisture-damaged building materials — concentrations and diversity , 2002 .

[4]  R. C. Cooke,et al.  Ecophysiology of Fungi , 1993 .

[5]  Gunilla Bok,et al.  Laboratory study to determine the critical moisture level for mould growth on building materials , 2012 .

[6]  Frank Devlieghere,et al.  Standardisation of methods for assessing mould germination: a workshop report. , 2006, International journal of food microbiology.

[7]  Pernilla Johansson,et al.  Validation of critical moisture conditions for mould growth on building materials , 2013 .

[8]  Staf Roels,et al.  Review of mould prediction models and their influence on mould risk evaluation , 2012 .

[9]  Karin Foarde,et al.  Assessment of fungal (Penicillium chrysogenum) growth on three HVAC duct materials , 1996 .

[10]  H. Viitanen,et al.  Mould growth on wood under fluctuating humidity conditions , 1994 .

[11]  Hannu Viitanen,et al.  The response of building materials to the mould exposure at different humidity and temperature conditions , 2000 .

[12]  Gunilla Bok,et al.  The effect of cyclic moisture and temperature on mould growth on wood compared to steady state conditions , 2013 .

[13]  J. Frisvad,et al.  Associations between Fungal Species and Water-Damaged Building Materials , 2011, Applied and Environmental Microbiology.