The accuracy and precision of signal source localization with tetrodes

Four-sensor microelectrodes, commonly referred to as tetrodes, have the ability to significantly increase the signal-to-noise ratio of neuronal extracellular recordings. They also provide spatio-temporal information about extracellular action potentials (EAP) which may be used to localize and resolve individual neuronal signal sources. Since the relative position of sensors and neurons whose EAPs are recorded is not known during in vivo experiments, the accuracy and precision of neuronal source localization algorithms remain untested. In this study, electrical signals generated by a stimulator were recorded simultaneously with four recording micropipettes immersed in artificial cerebrospinal fluid. The location of the source was estimated using the multiple signal classification algorithm, with an accuracy and precision of ~4 μm and ~7 μm, respectively. These results suggest that in vivo localization and resolution of individual neuronal sources is feasible.

[1]  A. Lee Swindlehurst,et al.  Efficient Dipole Parameter Estimation in EEG Systems With Near-ML Performance , 2012, IEEE Transactions on Biomedical Engineering.

[2]  Mandar S. Jog,et al.  Spike source localization with tetrodes , 2005, Journal of Neuroscience Methods.

[3]  Charles R. Johnson,et al.  Matrix analysis , 1985, Statistical Inference for Engineers and Data Scientists.

[4]  A. Lee Swindlehurst,et al.  Signal source localization with tetrodes: Experimental verification , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  G. Buzsáki,et al.  Characterization of neocortical principal cells and interneurons by network interactions and extracellular features. , 2004, Journal of neurophysiology.

[6]  Chang Won Lee,et al.  An Efficient Algorithm for Current Source Localization with Tetrodes , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Chang Won Lee A method for neural source identification , 2012 .

[8]  R. O. Schmidt,et al.  Multiple emitter location and signal Parameter estimation , 1986 .

[9]  Ifije E. Ohiorhenuan,et al.  Three-dimensional localization of neurons in cortical tetrode recordings. , 2011, Journal of neurophysiology.

[10]  Zoran Nenadic,et al.  Semi-chronic motorized microdrive and control algorithm for autonomously isolating and maintaining optimal extracellular action potentials. , 2005, Journal of neurophysiology.

[11]  A. A Emondi,et al.  Tracking neurons recorded from tetrodes across time , 2004, Journal of Neuroscience Methods.

[12]  B. McNaughton,et al.  Tetrodes markedly improve the reliability and yield of multiple single-unit isolation from multi-unit recordings in cat striate cortex , 1995, Journal of Neuroscience Methods.

[13]  Jonathan D. Victor,et al.  Dipole characterization of single neurons from their extracellular action potentials , 2011, Journal of Computational Neuroscience.

[14]  J. Csicsvari,et al.  Massively parallel recording of unit and local field potentials with silicon-based electrodes. , 2003, Journal of neurophysiology.

[15]  Joel W. Burdick,et al.  A control algorithm for autonomous optimization of extracellular recordings , 2006, IEEE Transactions on Biomedical Engineering.

[16]  Z. Somogyvári,et al.  Model-based source localization of extracellular action potentials , 2005, Journal of Neuroscience Methods.

[17]  J.C. Mosher,et al.  Recursive MUSIC: A framework for EEG and MEG source localization , 1998, IEEE Transactions on Biomedical Engineering.

[18]  A. Lee Swindlehurst,et al.  Projection Versus Prewhitening for EEG Interference Suppression , 2012, IEEE Transactions on Biomedical Engineering.