Canonical Decomposition of Ictal Scalp EEG and Accurate Source Localisation: Principles and Simulation Study

Long-term electroencephalographic (EEG) recordings are important in the presurgical evaluation of refractory partial epilepsy for the delineation of the ictal onset zones. In this paper, we introduce a new concept for an automatic, fast, and objective localisation of the ictal onset zone in ictal EEG recordings. Canonical decomposition of ictal EEG decomposes the EEG in atoms. One or more atoms are related to the seizure activity. A single dipole was then fitted to model the potential distribution of each epileptic atom. In this study, we performed a simulation study in order to estimate the dipole localisation error. Ictal dipole localisation was very accurate, even at low signal-to-noise ratios, was not affected by seizure activity frequency or frequency changes, and was minimally affected by the waveform and depth of the ictal onset zone location. Ictal dipole localisation error using 21 electrodes was around 10.0 mm and improved more than tenfold in the range of 0.5–1.0 mm using 148 channels. In conclusion, our simulation study of canonical decomposition of ictal scalp EEG allowed a robust and accurate localisation of the ictal onset zone.

[1]  M. Hallett,et al.  An improved method for localizing electric brain dipoles , 1990, IEEE Transactions on Biomedical Engineering.

[2]  Fumikazu Miwakeichi,et al.  Concurrent EEG/fMRI analysis by multiway Partial Least Squares , 2004, NeuroImage.

[3]  Joos Vandewalle,et al.  Computation of the Canonical Decomposition by Means of a Simultaneous Generalized Schur Decomposition , 2005, SIAM J. Matrix Anal. Appl..

[4]  A. Stegeman,et al.  On Kruskal's uniqueness condition for the Candecomp/Parafac decomposition , 2007 .

[5]  Kazutomo Yunokuchi,et al.  Tests of EEG localization accuracy using implanted sources in the human brain , 1991, Annals of neurology.

[6]  Robert Oostenveld,et al.  The five percent electrode system for high-resolution EEG and ERP measurements , 2001, Clinical Neurophysiology.

[7]  J S Ebersole,et al.  Noninvasive Localization of Epileptogenic Foci by EEG Source Modeling , 2000, Epilepsia.

[8]  H. Lüders,et al.  Presurgical evaluation of epilepsy. , 2001, Brain : a journal of neurology.

[9]  Richard M. Leahy,et al.  Electromagnetic brain mapping , 2001, IEEE Signal Process. Mag..

[10]  J Gotman,et al.  Separation of spikes from background by independent component analysis with dipole modeling and comparison to intracranial recording , 2001, Clinical Neurophysiology.

[11]  Rasmus Bro,et al.  Multiway analysis of epilepsy tensors , 2007, ISMB/ECCB.

[12]  David E. Booth,et al.  Multi-Way Analysis: Applications in the Chemical Sciences , 2005, Technometrics.

[13]  J Gotman,et al.  Reliability of dipole models of epileptic spikes , 1999, Clinical Neurophysiology.

[14]  Matthias Holschneider,et al.  Wavelet analysis of ellipticity, dispersion, and dissipation properties of Rayleigh waves , 2005 .

[15]  J. Gotman Automatic recognition of epileptic seizures in the EEG. , 1982, Electroencephalography and clinical neurophysiology.

[16]  Elena Urrestarazu,et al.  Independent Component Analysis Removing Artifacts in Ictal Recordings , 2004, Epilepsia.

[17]  I. Lemahieu,et al.  Influence of measurement noise and electrode mislocalisation on EEG dipole-source localisation , 2000, Medical and Biological Engineering and Computing.

[18]  J. Gotman,et al.  A system for automatic artifact removal in ictal scalp EEG based on independent component analysis and Bayesian classification , 2006, Clinical Neurophysiology.

[19]  Seiichiro Mine,et al.  Ictal dipole source analysis based on a realistic scalp–skull–brain head model in localizing the epileptogenic zone , 2005, Neuroscience Research.

[20]  L. Zhukov,et al.  Independent component analysis for EEG source localization , 2000, IEEE Engineering in Medicine and Biology Magazine.

[21]  D. Lehmann,et al.  Low resolution electromagnetic tomography: a new method for localizing electrical activity in the brain. , 1994, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[22]  G. Comi,et al.  IFCN standards for digital recording of clinical EEG. International Federation of Clinical Neurophysiology. , 1998, Electroencephalography and clinical neurophysiology.

[23]  Patrick Dupont,et al.  Canonical decomposition of ictal scalp EEG reliably detects the seizure onset zone , 2007, NeuroImage.

[24]  J. Chang,et al.  Analysis of individual differences in multidimensional scaling via an n-way generalization of “Eckart-Young” decomposition , 1970 .

[25]  F. L. Hitchcock The Expression of a Tensor or a Polyadic as a Sum of Products , 1927 .

[26]  Wim Van Paesschen,et al.  Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram , 2006, IEEE Transactions on Biomedical Engineering.

[27]  Donald W. Klass,et al.  The Continuing Challenge of Artifacts in the EEG , 1995 .

[28]  J. Gotman Noninvasive Methods for Evaluating the Localization and Propagation of Epileptic Activity , 2003, Epilepsia.

[29]  P. Paatero The Multilinear Engine—A Table-Driven, Least Squares Program for Solving Multilinear Problems, Including the n-Way Parallel Factor Analysis Model , 1999 .

[30]  W. van Paesschen,et al.  Improving the Interpretation of Ictal Scalp EEG: BSS–CCA Algorithm for Muscle Artifact Removal , 2007, Epilepsia.

[31]  M. Murray,et al.  EEG source imaging , 2004, Clinical Neurophysiology.

[32]  N. Sidiropoulos,et al.  On the uniqueness of multilinear decomposition of N‐way arrays , 2000 .

[33]  M. Scherg,et al.  Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model. , 1985, Electroencephalography and clinical neurophysiology.

[34]  R. Van de Walle,et al.  Muscle and eye movement artifact removal prior to EEG source localization , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[35]  J. Engel Update on surgical treatment of the epilepsies , 1993, Neurology.

[36]  J. Kruskal Three-way arrays: rank and uniqueness of trilinear decompositions, with application to arithmetic complexity and statistics , 1977 .

[37]  Richard A. Harshman,et al.  Foundations of the PARAFAC procedure: Models and conditions for an "explanatory" multi-model factor analysis , 1970 .

[38]  Bart Vanrumste,et al.  Ictal Source Localization in Presurgical Patients With Refractory Epilepsy , 2002, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[39]  Gregory A. Worrell,et al.  Ictal source analysis: Localization and imaging of causal interactions in humans , 2007, NeuroImage.

[40]  B N Cuffin,et al.  Accuracy of electroencephalographic dipole localization of epileptiform activities associated with focal brain lesions , 1998, Annals of neurology.

[41]  Thom F. Oostendorp,et al.  The conductivity of the human skull: results of in vivo and in vitro measurements , 2000, IEEE Transactions on Biomedical Engineering.

[42]  J. Gotman,et al.  Dipole Modeling of Epileptic Spikes Can Be Accurate or Misleading , 2005, Epilepsia.

[43]  Nikos D. Sidiropoulos,et al.  Robust iterative fitting of multilinear models , 2005, IEEE Transactions on Signal Processing.

[44]  Fumikazu Miwakeichi,et al.  Decomposing EEG data into space–time–frequency components using Parallel Factor Analysis , 2004, NeuroImage.

[45]  Rasmus Bro,et al.  Multi-way Analysis with Applications in the Chemical Sciences , 2004 .

[46]  Lieven De Lathauwer,et al.  A Link between the Canonical Decomposition in Multilinear Algebra and Simultaneous Matrix Diagonalization , 2006, SIAM J. Matrix Anal. Appl..